ms_power: Power of a group sequential log-rank design

View source: R/ms_power.R

ms_powerR Documentation

Power of a group sequential log-rank design

Description

Computes the analysis times, expected events, bounds, stopping probabilities, power and type I error of a design with a given sample size, without simulation.

Usage

ms_power(
  scenario,
  n,
  looks,
  test,
  events = NULL,
  followup = NULL,
  null_scenarios = NULL
)

Arguments

scenario

An ms_scenario object.

n

Total sample size.

looks

An ms_looks object.

test

An ms_test object.

events

Final number of events of the trigger endpoint (for event-driven looks), or final numbers of events named by endpoint ("os", "pfs").

followup

Time from the end of accrual to the final analysis (for an event-driven final look, instead of events).

null_scenarios

For two endpoints, an optional list of ms_scenario objects with the allocation and accrual of scenario, each named by the endpoint ("os" or "pfs") whose null hypothesis is true in the scenario, for example list(os = s_os).

Details

For event-driven looks, the final analysis takes place when the expected number of events of the trigger endpoint reaches events, or at followup after the end of accrual. The interim analyses take place when the expected number of events reaches the fractions given in looks. For calendar-driven looks, events and followup are not used.

At each look, the standardized log-rank statistics have the mean and covariance of lr_cov with the approximations chosen in test. The bounds are computed by gs_bounds and the stopping probabilities by gs_prob. The power is the probability of crossing an efficacy bound when the futility bounds are applied. The type I error is computed under ms_null applied to the scenario, with event-driven looks at the same numbers of events of the trigger endpoint; the non-binding value ignores the futility bounds and the binding value applies them.

The power and the type I error rest on the normal approximation of the log-rank statistics. With unequal allocation and few events the statistic is skewed, so that the probability of rejecting in favor of the treatment exceeds the computed type I error when the treatment group is the larger group, and falls below it when the control group is: by simulation (inst/validation of the source package), about 0.028 instead of 0.025 with 2:1 allocation and looks at 75 and 150 deaths.

The hazard ratios at the bounds are exp(-z / sqrt(p0 p1 d)), where d is the expected number of events of the tested endpoint.

The expected study duration, number of events of the tested endpoint and number of enrolled patients (expected) are the sums over the looks of the probability of stopping at the look times the calendar time, the expected events and the enrolled patients at the look, under the design scenario and under ms_null applied to the scenario (at the looks of the type I error, looks_null). The trial stops at an interim look when the statistic crosses the efficacy bound or falls below the futility bound, also when the futility bounds are non-binding, as in gsProbability() of gsDesign; the probability of stopping at the last look is one minus the probability of stopping earlier. With non-binding futility bounds the efficacy bounds do not depend on the futility bounds, so that the expected values without stopping for futility are those of the same design with futility = "none". At an event-driven look the events are the target, and the calendar time and the enrolled patients are those at which the expected events reach the target: the variability of the analysis time and its correlation with the decision to stop are ignored, as in the expected study durations of rpact and lrstat. At a calendar-driven look the time is exact and the events are expected. A final look at followup after the end of accrual takes place under the null scenario when the expected events reach those of the design scenario, as for the type I error.

When the looks have different triggers (see ms_looks), each trigger endpoint has its own final number of events, and a look driven by it takes place when its expected number of events reaches the fraction of the look times that number. The final numbers are given by events, named by endpoint when the looks are driven by the events of two endpoints, for example c(pfs = 300, os = 250). With followup, or without events when the final look is calendar-driven, they are the expected numbers of events at the final analysis; the looks driven by an endpoint other than that of the final look then need fractions below 1.

With two endpoints (test from ms_test with two endpoints), the statistics of the two endpoints at the looks at which they are tested have the joint distribution of lr_cov, with the observed events of the trigger endpoints determining the event-driven looks for variance = "studentized". Each endpoint has its own bounds, and the rejection probabilities under the multiple testing procedure are computed by gs_prob_mtp; with recycling of the level (transition of ms_test), each endpoint also has bounds at its level after recycling. The familywise error rate is computed under ms_null applied to the scenario (the global null hypothesis), where the correlations between the endpoints are those of Danzer et al. (2025, Theorem 1), and under each scenario of null_scenarios, where the hypothesis of one endpoint is true and that of the other is not (a partial null hypothesis). Such scenarios cannot be derived from the multistate model of the design scenario and are given by the user, for example a model with the same OS in both groups and a difference in PFS. Under each null scenario the event-driven looks take place at the same numbers of events of their trigger endpoints.

With switching from a calendar time (switch_start of ms_scenario), only a test of one endpoint with mean = "direct" for OS is covered, and an OS test cannot use looks driven by PFS events. For OS the covariance of the statistics comes from the per-patient influence functions (see lr_cov); the bounds still come from the information or event fractions, and the type I error under ms_null uses the exact correlations under the null hypothesis, so it can differ from alpha when the switching changes the death hazard.

Value

An object of class ms_power, a list with

looks

A data frame with one row per look: time, enrolled, the expected events of the tested endpoint (events, events_control, events_treatment), info_frac, the efficacy bound (z_upper, nominal one-sided p-value p_upper, hazard ratio hr_upper), the futility bound (z_lower, hr_lower), the mean and standard deviation of the statistic (z_mean, z_sd), the probabilities of stopping for efficacy and futility at the look (prob_upper, prob_lower), the cumulative power cum_power, the cumulative alpha spent alpha_spent and the cumulative non-binding type I error cum_alpha. When the looks are driven by another endpoint, events_trigger gives the events of that endpoint.

power

Overall power.

type1

Type I error, non-binding and binding.

n, accrual_duration, study_duration, events

Sample size, accrual duration, calendar time of the final analysis and expected events of the tested endpoint at the final analysis.

expected

A data frame with the expected values when the trial stops at the bounds (see Details), with one row per hypothesis (hypothesis: "design" for the design scenario and "null" for the null scenario): the probabilities of stopping at an interim look for efficacy (prob_efficacy_early) and for futility (prob_futility_early), and the expected study_duration, events of the tested endpoint and enrolled patients.

mean, sigma

The mean vector and covariance matrix of the statistics at the looks under the design scenario.

targets

The numbers of events of the trigger endpoints at which the event-driven looks take place (NA for calendar-driven looks).

settings, scenario, looks_def, test

The inputs.

looks_null

A data frame with one row per look under the null scenario: look, time, enrolled, events and the probabilities of stopping for efficacy and for futility at the look with the futility bounds applied (prob_upper, prob_lower).

sigma_null

The correlation matrix of the statistics under the null scenario.

With two endpoints, looks has one row per endpoint and look at which the endpoint is tested, with the columns above and endpoint, look, trigger and events_trigger (the events of the trigger endpoint at the look, NA for calendar-driven looks); prob_upper is the probability of rejecting the hypothesis of the endpoint at the look under the multiple testing procedure (with recycling of the level, z_upper_recycled and p_upper_recycled give the efficacy bound and its nominal p-value at the level after the other hypothesis has been rejected, after hr_upper), prob_lower the probability of stopping for futility at the look (first endpoint), cum_power the cumulative sum of prob_upper, alpha_spent the cumulative alpha of the bounds of the endpoint and cum_alpha the cumulative non-binding probability of rejecting the hypothesis of the endpoint under the global null hypothesis. power has the powers of the two endpoints (named by endpoint), the probability of rejecting both hypotheses (both) and of rejecting at least one (any); type1 is the familywise error rate under the global null hypothesis, non-binding and binding; fwer is a data frame with the familywise error rate under the global null hypothesis and under each scenario of null_scenarios; events has the expected events of each endpoint at its last look; final_events the final numbers of events of the trigger endpoints; and mean and sigma are the mean vector and covariance matrix of the statistics in the order of the rows of looks. The expected values (expected, looks_null, sigma_null) and targets are not given.

References

Danzer MF, Rufibach K, Beyersmann J, Schmidt R (2025). Exhausting the type I error level in event-driven group-sequential designs with a closed testing procedure for progression-free and overall survival. arXiv:2512.08658.

See Also

ms_size, ms_looks, ms_test, gs_prob_mtp

Examples

ctl <- ms_model(death = log(2) / 12)
trt <- ms_model(death = 0.7 * log(2) / 12)
scn <- ms_scenario(ctl, trt, accrual = ms_accrual(rate = 20))
ms_power(scn, n = 400, looks = ms_looks("os", fraction = c(0.5, 1)),
         test = ms_test(), events = 300)

# PFS first, then OS: final PFS analysis at 300 PFS events with an OS
# interim analysis, final OS analysis at 220 OS events
fl <- ms_scenario(ms_fleischer(4, 12), ms_fleischer(6, 16),
                  accrual = ms_accrual(rate = 25))
lk <- ms_looks(c("pfs", "os"), fraction = c(1, 1), test = list(c("pfs", "os"), "os"))
ms_power(fl, n = 450, looks = lk,
         test = ms_test(endpoints = c("pfs", "os"), mtp = "fixed_sequence"),
         events = c(pfs = 300, os = 220))