get_mesh_agree_pair | R Documentation |
Calculates distance-based as well as volume-overlap-based agreement measures for comparing a single pair of 3D meshes.
get_mesh_agree_pair(x, metro, ui, boov=FALSE, do_ui=FALSE, chop=TRUE, ...)
x |
|
metro |
If already available, the distance-based measures as returned by |
ui |
If already available, the mesh union and intersection as returned by |
boov |
|
do_ui |
|
chop |
|
... |
Options passed to |
Currently, no mesh can be designated gold standard. get_mesh_agree
calculates the agreement for a list of observer/mesh objects. get_mesh_metro_pair
calculates the pairwise distances. get_mesh_ui_pair
calculates the mesh union and intersection. For boov=TRUE
, package Boov
has to be installed separately.
data.frame
with these variables
mesh_1 |
Name of the first mesh of the pair. |
mesh_2 |
Name of the second mesh of the pair. |
group |
The grouping variable indicating which pairs belong to the same structure. |
vol_1 |
Volume of the first mesh of the pair. |
vol_2 |
Volume of the second mesh of the pair. |
vol_u |
Volume of the union. |
vol_i |
Volume of the intersection. |
DCOM |
Euclidean distance between the respective center of mass of both meshes. |
HD_max |
Hausdorff distance - worst case, maximum of both directed Hausdorff distances. |
HD_avg |
Hausdorff distance - average, mean of both directed Hausdorff distancess. |
ASD |
Average symmetric surface distance. |
RMSD |
Root mean squared symmetric surface distance. |
JSC |
Jaccard similarity coefficient. |
DSC |
Dice similarity coefficient. |
Fotina et al. Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy. Strahlenther Onkol 2012; 188: 160-167.
Hanna et al. Geometrical Analysis of Radiotherapy Target Volume Delineation: a Systematic Review of Reported Comparison Methods. Clin Oncol 2010; 22, 515-525.
Heimann et al. Comparison and Evaluation of Methods for Liver Segmentation From CT Datasets. IEEE Trans Med Imaging 2009; 28: 1251-1265.
Sherer et al. Metrics to evaluate the performance of auto-segmentation for radiation treatment planning: A critical review. Radiother Oncol 2021; 160: 185-191.
http://vcg.isti.cnr.it/vcglib/
get_mesh_pairs
,
get_mesh_metro_pair
,
get_mesh_ui_pair
heartL <- mesh3dL_to_cgalMeshL(data_heart_obsL) pairL <- get_mesh_pairs(heartL) get_mesh_agree_pair(pairL[[1]], do_ui=FALSE, nSamples=500L, silent=TRUE)
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.