| dataset12 | R Documentation |
This is referred to in the code as the "DOB2" dataset. It contains actionability ratings, i.e., do you recommend further follow up on the patient, one a 1 (definitely not) to 5 (definitely yes), effectively an ROC dataset using a 5-point rating scale.
dataset12
A list with 3 elements: $ratings, $lesions and $descriptions; $ratings
contain 3 elements, $NL, $LL and $LL_IL as sub-lists; $lesions
contain 3 elements, $perCase, $IDs and $weights as sub-lists; $descriptions
contain 7 elements, $fileName, $type, $name,
$truthTableStr, $design, $modalityID and $readerID as sub-lists;
rating$NL, num [1:4, 1:5, 1:152, 1], ratings of non-lesion localizations, NLs
rating$LL, num [1:4, 1:5, 1:88, 1], ratings of lesion localizations, LLs
rating$LL_ILNA, this placeholder is used only for LROC data
lesions$perCase, int [1:88], number of lesions per diseased case
lesions$IDs, num [1:88, 1], numeric labels of lesions on diseased cases
lesions$weights, num [1:88, 1], weights (or clinical importances) of lesions
descriptions$fileName, chr, "dataset12", base name of dataset in 'data' folder
descriptions$type, chr "ROC", the data type
descriptions$name, chr "DOBBINS-2", the name of the dataset
descriptions$truthTableStr, num [1:4, 1:5, 1:152, 1:2] , truth table structure
descriptions$design, chr "FCTRL", study design, factorial dataset
descriptions$modalityID, chr [1:4] "1" "2" "3" "4", treatment label(s)
descriptions$readerID, chr [1:5] "1" "2" "3" "4" ..., reader labels
Dobbins III JT et al. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules. Radiology. 2016;282(1):236-250.