Nothing
#' @keywords internal
"_PACKAGE"
## usethis namespace: start
#' @importFrom pracma geo_median
#' @import MASS
#' @import stats
#' @import mathjaxr
#' @importFrom graphics abline axis frame legend lines mtext panel.smooth par points strheight strwidth text title
#' @importFrom grDevices as.graphicsAnnot dev.flush dev.hold dev.interactive devAskNewPage extendrange
#' @importFrom methods formalArgs
## usethis namespace: end
NULL
#' AC (Complex) Hall effect data measured from a thin-film copper sample.
#'
#' This data serves as a 'real-world' example of complex valued measurements that can be analyzed by the methods contained
#' in 'complexlm'. The Hall effect is a perpendicular (to the magnetic field and current) voltage that appears across an
#' electrically conductive material when it is placed in an external magnetic field. It is commonly used to determine the
#' mobility and density of charge carriers (electrons and/or holes) within materials.
#'
#' The AC Hall effect is a more advanced technique that uses a time varying (sinusoidal) magnetic field and lock-in voltage
#' measurement. The measured output signal is thus a wave, and best described by complex numbers. This strategy drastically
#' lowers the noise floor, enabling measurement of difficult, low-mobility, materials.
#'
#' This data was take at room temperature in a vacuum chamber using a custom built and programmed system. A Keithley 2636
#' sourcemeter provided the excitation current, while an SRS 830 lock-in amplifier measured the voltage signal from the sample.
#' The sample consisted of a 0.8 mm square of 1000 Angstroms thick evaporated copper film on a 1.5 centimeter square die of oxidized crystalline silicon.
#'
#' The variables included in the dataframe are as follows:
#'
#' \describe{
#' \item{Temperature.K.}{ The temperature of the sample during this measurement. Units of Kelvin.}
#' \item{Magnet.Field.Frequency.Hz.}{ The frequency of the oscillating magnetic field used for this measurement. Units are Hertz.}
#' \item{Magnetic.Field.T.}{ The amplitude of the magnetic field during this measurement. Units of Tesla.}
#' \item{Contact.Arrangement}{ This measurement involves four electrical contacts (current in and out, and voltage hi and lo), placed at the corners.
#' Corresponding contacts must be opposite each other, so there are two possible arrangements: "D" and "F".}
#' \item{Current.Set.A.}{ The desired current to be sent through the sample for this measurement. There was an error in recording beyond the 8th row. Units of Amperes.}
#' \item{Current.In.meas.A.}{ The current measured leaving the sourcemeter, towards the sample. Units of Amperes.}
#' \item{Current.Out.meas.A.}{ The current measured exiting the sample. Units of Amperes.}
#' \item{Source.V.V.}{ The voltage generated across the sample in order to produce the desired current. Units of Volts.}
#' \item{OutputV}{ The complex voltage measured across the sample. Ideally proportional to the current and magnetic field. Units of Volts.}
#' \item{Current.leak}{ The difference between the input and output currents. Units of Amperes.}
#' \item{Resistivity.Ohm.cm}{ The resistivity of the sample as calculated by the Van Der Pauw method from previous DC current-voltage sweeps. Units of Ohm*centimeter.}
#' \item{thickness.cm.}{ The thickness of the copper film in centimeters.}
#' }
#'
#' @keywords datasets
#' @format A dataframe with 240 rows and 11 columns. Most names contain the units of the column after the last or second to last period.
#' @author William Ryan \email{wryan1@binghamton.edu}
#'
"CuHallData"
Any scripts or data that you put into this service are public.
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.