View source: R/076-calibration-quality-uncertainty-0-9.R
| estimate_calibration_error | R Documentation |
Estimate empirical calibration/validation error
estimate_calibration_error(
data,
gaze_x = "gaze_x",
gaze_y = "gaze_y",
target_x = "target_x",
target_y = "target_y",
by = NULL
)
data |
Validation-target data. |
gaze_x, gaze_y |
Recorded gaze-coordinate columns. |
target_x, target_y |
Known target-coordinate columns. |
by |
Optional grouping columns such as participant/session. |
A tabular R object containing empirical calibration/validation error; rows represent analysis units and columns contain the returned quantities.