.get_H | R Documentation |
H: sensible heat flux density (W / m^2)
.get_H(T_leaf, pars, unitless)
T_leaf |
Leaf temperature in Kelvin |
pars |
Concatenated parameters ( |
unitless |
Logical. Should function use parameters with |
H = P_a c_p g_h * (T_leaf - T_air)
Symbol | R | Description | Units | Default |
c_p | c_p | heat capacity of air | J / (g K) | 1.01 |
g_h | g_h | boundary layer conductance to heat | m / s | calculated |
P_a | P_a | density of dry air | g / m^3 | calculated |
T_air | T_air | air temperature | K | 298.15 |
T_leaf | T_leaf | leaf temperature | K | input |
Value in W / m^2 of class units
.get_gh
, .get_Pa
library(tealeaves) cs <- make_constants() ep <- make_enviropar() lp <- make_leafpar() T_leaf <- set_units(298.15, K) tealeaves:::.get_H(T_leaf, c(cs, ep, lp), FALSE)
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.