View source: R/fd_remote_sensing.R
fd_ceptometer | R Documentation |
Ceptometer derived light interception data
fd_ceptometer()
data on light interception, as faPAR or the fraction of absorbed photosynthetically
available radiation, based on the difference between above and below canopy PAR as measured by
a Decagon LP-80 handheld ceptometer. Units of a_par
, above canopy PAR, and b_par
, below canopy PAR,
are in units of micromoles per square meter per second while fapar
and lai_cept
, leaf area index derived
from light data, are ratio-based, unitless data. Entries where the notes
column has entries may refer to original values
where the a_par
value was replaced with data from the nearby UMBS AmeriFlux tower PAR sensor due to ceptometer instrument
issues with securing clear sky PAR readings. Tower PAR readings were synced in time and then adjusted with the calibration
equation A_par = 1.15x - 187.827, where x = the Tower PAR reading. This is an empirically derived equation from several calibration
readings found in the supplemental section of Atkins et al. (In Prep)–to be updated when submitted.
A data.frame
or tibble
. See "Details" for column descriptions.
Call fd_metadata
for field metadata.
Data were collected by Jeff W. Atkins and Brandon Alveshare using a Decagon LP-80 Handheld Ceptometer
fd_ceptometer()
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.