View source: R/airsis_ESAMQualityControl.R
| airsis_ESAMQualityControl | R Documentation | 
Perform various QC measures on AIRSIS E-Sampler data.
The following columns of data are tested against valid ranges:
Flow
AT
RHi
ConcHr
A POSIXct datetime column (UTC) is also added based on TimeStamp.
airsis_ESAMQualityControl(
  tbl,
  valid_Longitude = c(-180, 180),
  valid_Latitude = c(-90, 90),
  remove_Lon_zero = TRUE,
  remove_Lat_zero = TRUE,
  valid_Flow = c(1.999, 2.001),
  valid_AT = c(-Inf, 150),
  valid_RHi = c(-Inf, 55),
  valid_Conc = c(-Inf, 5000),
  flagAndKeep = FALSE
)
| tbl | single site tibble created by  | 
| valid_Longitude | range of valid Longitude values | 
| valid_Latitude | range of valid Latitude values | 
| remove_Lon_zero | flag to remove rows where Longitude == 0 | 
| remove_Lat_zero | flag to remove rows where Latitude == 0 | 
| valid_Flow | range of valid Flow.l.m values | 
| valid_AT | range of valid AT.C. values | 
| valid_RHi | range of valid RHi... values | 
| valid_Conc | range of valid Conc.mg.m3. values | 
| flagAndKeep | flag, rather then remove, bad data during the QC process | 
Cleaned up tibble of AIRSIS monitor data.
airsis_qualityControl
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.