Description Usage Arguments Value
View source: R/DO_units_convert.R
DO_convert_units
accepts dissolved oxygen and temperature measurements
and adjusts dissolved oxygen based on solubility of oxygen at
different temperatures. Uses USGS methods (citing Garcia and Gordon, 1992)
found here: https://water.usgs.gov/admin/memo/QW/qw11.03.pdf
1 2 3 4 5 | DO_adjust_units(
temperature,
dissolved_oxygen,
salinity = rep(0, length(temperature))
)
|
temperature |
A vector or 1-D column of temperature measurements that coincide with conductivity measurements |
dissolved_oxygen |
A vector or 1-D column of dissolved measurements that coincide with temperature measurements |
salinity |
A vector or 1-D column of salinity measurements that coincide with temperature measurements |
Dissolved oxygen values converted to percent saturation
Add the following code to your website.