IREQ: IREQ

View source: R/IREQ.r

IREQR Documentation

IREQ

Description

Calculation of Required Clothing Insulation IREQ.

Usage

IREQ(t, rh, wind, tr, M, W, clo, p, w, param = "IREQ_neutral")

Arguments

t

numeric Air temperature in degC.

rh

numeric Relative humidity in percentage.

wind

numeric Windspeed in meter per second.

tr

numeric Mean radiant temperature in degC.

M

numeric Metabolic work in Watt per mq of the subject.

W

numeric Mechanical work rate in Watt per mq of the subject.

clo

numeric Available basic clothing insulation in clo.

p

numeric Air permeability of clothing ensemble lt on meters per second.

w

numeric Walking speed in meters per second.

param

character Parameter of IREQ ISO 11079: "IREQ_neutral","IREQ_min","ICL_neutral","ICL_min","DLE_neutral","DLE_min","ICL_ISO11079"

Value

IREQ value

Author(s)

Istituto per la Bioeconomia CNR Firenze Italy Alfonso Crisci alfonso.crisci@ibe.cnr.it

References

ISO 11079, 2007-12-15, ERGONOMICS OF THE THERMAL ENVIRONMENT - DETERMINATION AND INTERPRETATION OF COLD STRESS WHEN USING REQUIRED CLOTHING INSULATION (IREQ) AND LOCAL COOLING EFFECTS.


alfcrisci/rBiometeo documentation built on Feb. 1, 2024, 4:47 p.m.