correct_ph_temp: Correct measured pH for temperature

Description Usage Arguments

View source: R/carbon_calc.R

Description

Correct measured pH for temperature

Usage

1
2
correct_ph_temp(pH, temp1, temp2, sal = 35, alk = 2400, n_max = 100,
  marg = 0.01)

Arguments

pH

measured pH

temp1

temperature at which pH was measured

temp2

in-situ temperature from samples origin

sal

salinity of sample

alk

measured alkalinity

n_max

maximum number of iterations

marg

fineness of result