epi.temperature: Get volumetrically averaged epilimnion temp

Description Usage Arguments See Also

Description

Calculates volumetrically weighted average epilimnetic temperature using the supplied water temperature timeseries. If the lake is not stratified, the bottom of the epilimnion is calculated as the full depth of the lake.

Usage

1
epi.temperature(wtr, depths, bthA, bthD)

Arguments

wtr

a numeric vector of water temperature in degrees C.

depths

a numeric vector corresponding to the depths (in m) of the wtr measurements

bthA

a numeric vector of cross sectional areas (m^2) corresponding to bthD depths

bthD

a numeric vector of depths (m) which correspond to areal measures in bthA

See Also

hypo.temperature, whole.lake.temperature


clairervh/GLEON documentation built on May 12, 2019, 2:04 p.m.