context("part_full")
# https://www.engineersedge.com/fluid_flow/partially_full_pipe_flow_calculation/partiallyfullpipeflow_calculation.htm
test_that("dimensional parameters are correct" , {
expect_equal(round(part_full_area(15,36)/144,2), 2.79)
expect_equal(round(part_full_perimeter(15,36)/12,1), 4.2)
expect_equal(round(part_full_hyd_radius(15,36)/12,2), 0.66)
expect_equal(round(part_full_area(2,8)/144,2), 0.07)
expect_equal(round(part_full_perimeter(2,8)/12,1), 0.7)
expect_equal(round(part_full_hyd_radius(2,8)/12,2), 0.10)
expect_equal(round(part_full_area(20,24)/144,2), 2.8)
expect_equal(round(part_full_perimeter(20,24)/12,1), 4.6)
expect_equal(round(part_full_hyd_radius(20,24)/12,2), 0.61)
})
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.