cc0_filt: cc0_filt Function This function calculates the ratio of TSS...

Description Usage Arguments Examples

Description

cc0_filt Function This function calculates the ratio of TSS concentration to original TSS concentration at a distance of LENGTH. The default units are "m" but distance units (LENGTH_UNIT) of cm and ft are also applicable.

Usage

1
2
3
cc0_filt(LENGTH = 500, LENGTH_UNIT = "m", alpha = 1, Kx = 0.02,
  GRAD = 7e-04, POR = 0.21, K_units = "cm/s", TEMP = 25,
  DIA_SUSP = 1e-04, DIA_SOIL = 0.053, PART_DENS = 2.64)

Arguments

LENGTH

Distance at which to calculate the ratio of TSS concentration to original TSS concentration. Defaults to a value of 500

LENGTH_UNIT

Unit of length measurement. Defaults to a value of "m". Other options are "meter", "meters", "cm", "centimeter", "centimeters", "ft", "foot", "feet".

alpha

Factor that accounts for chemical affects on particle removal. Defaults to a value of 1 (i.e., chemical affects do not enhance particle removal

Kx

Defaults to a value of 0.02 cm/s

GRAD

Defaults to a value of 0.0007

POR

Defaults to a value of 0.21. The value of 0.21 is the average for medium sand as reported by Johnson (1967)

K_units

Units of hydraulic conductivity. Defaults to cm/s but also accepts ft/day. Units should be surrounded by quotation marks to ensure it is treated as a string of text.

TEMP

Temperature in units of °C. Defaults to a value of 25°C

DIA_SUSP

Diameter of the suspended solids in units of cm

DIA_SOIL

Diameter of the soil particles in units of cm

PART_DENS

Density of the suspended particle in units of g/cm³

Examples

1
2
L_filt()
[1] 0.2625636