Thes: Compute temperature of heat exchange surface

View source: R/simplemodel.R

ThesR Documentation

Compute temperature of heat exchange surface

Description

Function to compute the temperature of the heat exchange surface of a vegetated canopy.

Usage

Thes(
  climdata,
  lat,
  long,
  hgt,
  pai,
  x = 1,
  gsmax = 0.33,
  slope = 0,
  aspect = 0,
  alb = 0.23,
  galb = 0.15,
  zu = 2,
  Bowen = 1.5,
  upper = 25,
  umin = 0.5,
  merid = 0,
  dst = 0,
  clump = 0,
  method = "S",
  lims = "FALSE"
)

Arguments

climdata

a dataframe of hourly weather data formated and with units as per the internal dataset climdata

lat

the latitude of the location (decimal degrees)

long

the longitude of the location (decimal degrees)

hgt

canopy height (m)

pai

the total one sided area of canopy elements per unit ground area (see details)

x

leaf distribution angle coefficient

gsmax

maximum stomatal conductance of leaves (mol / m^2 / s)

slope

the slope of the underlying ground surface (decimal degrees). Ignored if method = S.

aspect

the aspect of the underlying ground surface (decimal degrees). Ignored if method = S.

alb

the albedo of the canopy surface (either the combined ground and canopy albedo if method = S or just the canopy albedo)

galb

ground surface albedo

zu

the height above ground of wind speeds in climdata (m)

Bowen

Optional parameter specifying the Bowen Ratio of the surface. Used to improve estimates of temperature in application of the Penman-Monteith equation

upper

optional upper limit to temperature offset (difference between reference and canopy surface temperature cannot exceed this value). Ignored if lims = FALSE

umin

optional minimum wind speed for computing conductances (avoids conductances being too low)

merid

an optional numeric value representing the longitude (decimal degrees) of the local time zone meridian (0 for GMT)

dst

an optional numeric value representing the time difference from the timezone meridian (hours, e.g. +1 for BST if merid = 0).

clump

clumpiness factor (0-1, see details)

method

if S treats the vegetation surface as a flat surface (see details)

lims

optional logical indicating whether to limit temperatures by upper and dewpoint temperature

Details

if pai is unknown it can be estimated as -ln(1-fractional canopy cover). if clump = 0 the canopy is assumed entirely uniform and radiation transmission is as for a turbid medium. As clump approaches 1, the canopy is assumed to be increasingly patchy, such that a greater proportion of reaches the ground without being obscured by leaves. If method = S, the radiation intercepted by the canopy is assumed to be that for a flat surface. If method is not S, the radiation absorption by the gorund and canopy surface are computed separately accounting for the inclination of the ground surface and the distribution of leaf angles.

Value

a vector of temperatures (deg C) of the canopy heat exchange surface

Examples

# Compute temperature a surface
Tref<-Thes(climdata,50.2178,-5.32656,hgt=0.5,pai=2,x=1,gsmax=0.33,alb=0.23,method="C",lims=TRUE)
plot(Tref,type="l")