#' Annual data on oil spills in the US from 2010 onward
#'
#' Distribution, Transmission & Gathering, LNG, and Liquid Accident and Incident Data.
#'
#' Title 49 of the Code of Federal Regulations (49 CFR Parts 191, 195) requires
#' pipeline operators to submit incident reports within 30 days of a pipeline
#' incident or accident. The CFR defines accidents and incidents, as well as
#' criteria for submitting reports to the Office of Pipeline Safety. The
#' following kinds of information are collected:
#' * Key report information
#' * In-depth location information
#' * Facility information
#' * Operating information
#' * Drug and Alcohol information
#' * Cause of the accident/incident
#' Specific information includes the time and location of the incident(s),
#' number of any injuries and/ or fatalities, commodity spilled/gas released,
#' causes of failure and evacuation procedures. The reports are used for
#' identifying long- and short-term trends at the national, state and
#' operator-specific levels. The frequency, causes, and consequences of the
#' incidents provide insight into the safety metrics currently used by PHMSA,
#' state partners, and other pipeline safety stakeholders, including the
#' pipeline industry and general public. PHMSA also uses the data for inspection
#' planning and risk assessment.
#'
#' @source United States Department of Transportation (DOT) Pipeline and
#' Hazardous Materials Safety Administration (PHMSA).
#' \url{https://www.phmsa.dot.gov/data-and-statistics/pipeline/distribution-transmission-gathering-lng-and-liquid-accident-and-incident-data}
#' (right side bar).
#' @format A data frame with columns:
#' \describe{
#' \item{DATAFILE_AS_OF}{}
#' \item{significant}{Identify if record meets the significant criteria or not: If there was fatality, injury, fire, explosion, total property damage $50K or more in 1984 dollars, non-HVL loss >= 50bbls, HVL loss >= 5bbls, then SIGNIFICANT=’YES’, else SIGNIFICANT=’NO’. See also: \url{https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/pdmpublic_incident_page_allrpt.pdf}.}
#' \item{serious}{Identify if record meets the SERIOUS criteria or not: If there was fatality or injury then SERIOUS = ‘YES’ else SERIOUS = ’NO’.}
#' \item{ipe}{Impacting People or the Environment (IPE) – when commodity (A8) is crude oil, refined petroleum products, of biofuel, if either criterion 1 or 2 below is met, the accident counts as IPE : 1. Regardless of Location of Accident (B10): Fatality (A12) greater than zero; or Injury requiring in-patient hospitalization (A13) greater than zero; or Ignition (A15) = Yes; or Explosion (A16) = Yes; or Evacuation (A17) greater than zero; or Wildlife impact (D1) = Yes; or Water contamination (D5a) = Ocean/Seawater, Groundwater, or Drinking water; or Public/Non-Operator Private Property Damage (D8a) greater than zero 2.For Location of Accident (B10) not “TOTALLY CONTAINED ON OPERATOR CONTROLLED PROPERTY”: Unintentional Release Volume (A9) greater than or equal to 5 gallons AND HCA (D7) = Yes; or Unintentional Release Volume (A9) greater than or equal to 5 barrels AND HCA (D7) = No; or Water contamination (D5a) = Surface; or Soil contamination (D2) = Yes.}
#' \item{integrity_assessment_target}{Integrity Assessment Target – accidents Impacting People or the Environment (IPE) and one of these causes: Corrosion, Pipeline/Weld Material Failure, Failure of Previously Damage Pipe – caused by Excavation Damage or Other Outside Force Damage.}
#' \item{operations_maintenance_target}{Operation & Maintenance Target - accidents Impacting People or the Environment (IPE) and one of these causes: Equipment Failure, Incorrect Operation, 1st & 2nd Party Excavation Damage, 3rd Party Excavation Damage with Root Cause = Locating Practices Not Sufficient.}
#' \item{incident_ID}{Unique incident ID. Also called report ID or report number.}
#' \item{SUPPLEMENTAL_NUMBER}{}
#' \item{REPORT_RECEIVED_DATE}{}
#' \item{REPORT_TYPE}{}
#' \item{ID}{Unique operator ID.}
#' \item{name}{Name of the pipelines operator at the time of the incident (year).}
#' \item{year}{Year accident occurred, derived from accident date.}
#' \item{OPERATOR_STREET_ADDRESS}{}
#' \item{OPERATOR_CITY_NAME}{}
#' \item{OPERATOR_STATE_ABBREVIATION}{}
#' \item{OPERATOR_POSTAL_CODE}{}
#' \item{LOCAL_DATETIME}{}
#' \item{lat}{Accident location latitude.}
#' \item{long}{Accident location longitude.}
#' \item{NRC_RPT_NUM}{}
#' \item{NRC_RPT_DATETIME}{}
#' \item{commodity}{The type of commodity being spilled (Crude, HVL, etc.).}
#' \item{COMMODITY_SUBTYPE}{}
#' \item{COMMODITY_DETAILS}{}
#' \item{BLEND_DETAILS}{}
#' \item{BIO_DIESEL_DETAILS}{}
#' \item{volume}{Volume of the spill.}
#' \item{INTENTIONAL_RELEASE_BBLS}{}
#' \item{recovered}{Estimated volume of commodity recovered (barrels).}
#' \item{net_loss}{Volume of commodity unintentionally released (in barrels) minus volume recovered.}
#' \item{FATALITY_IND}{}
#' \item{NUM_EMP_FATALITIES}{}
#' \item{NUM_CONTR_FATALITIES}{}
#' \item{NUM_ER_FATALITIES}{}
#' \item{NUM_WORKER_FATALITIES}{}
#' \item{NUM_GP_FATALITIES}{}
#' \item{fatalities}{Total number of Fatalities.}
#' \item{INJURY_IND}{}
#' \item{NUM_EMP_INJURIES}{}
#' \item{NUM_CONTR_INJURIES}{}
#' \item{NUM_ER_INJURIES}{}
#' \item{NUM_WORKER_INJURIES}{}
#' \item{NUM_GP_INJURIES}{}
#' \item{injuries}{Total number of Injuries.}
#' \item{SHUTDOWN_DUE_ACCIDENT_IND}{}
#' \item{SHUTDOWN_EXPLAIN}{}
#' \item{SHUTDOWN_DATETIME}{}
#' \item{RESTART_DATETIME}{}
#' \item{STILL_SHUTDOWN_IND}{}
#' \item{fire}{Commodity ignite (TRUE/FALSE).}
#' \item{explosion}{Commodity explode (TRUE/FALSE).}
#' \item{NUM_PUB_EVACUATED}{}
#' \item{INCIDENT_IDENTIFIED_DATETIME}{}
#' \item{ON_SITE_DATETIME}{}
#' \item{on_offshore}{Whether the oil spill occured onshore or offshore.}
#' \item{ONSHORE_STATE_ABBREVIATION}{}
#' \item{ONSHORE_POSTAL_CODE}{}
#' \item{ONSHORE_CITY_NAME}{}
#' \item{ONSHORE_COUNTY_NAME}{}
#' \item{DESIGNATED_LOCATION}{}
#' \item{DESIGNATED_NAME}{}
#' \item{PIPE_FAC_NAME}{}
#' \item{SEGMENT_NAME}{}
#' \item{FEDERAL}{}
#' \item{LOCATION_TYPE}{}
#' \item{INCIDENT_AREA_TYPE}{}
#' \item{INCIDENT_AREA_SUBTYPE}{}
#' \item{INCIDENT_AREA_DETAILS}{}
#' \item{DEPTH_OF_COVER}{}
#' \item{CROSSING}{}
#' \item{BRIDGE_CROSSING_IND}{}
#' \item{BRIDGE_TYPE}{}
#' \item{RAILROAD_CROSSING_IND}{}
#' \item{RAILROAD_TYPE}{}
#' \item{ROAD_CROSSING_IND}{}
#' \item{ROAD_TYPE}{}
#' \item{WATER_CROSSING_IND}{}
#' \item{WATER_TYPE}{}
#' \item{WATER_NAME}{}
#' \item{WATER_DEPTH}{}
#' \item{WATER_SUBTYPE}{}
#' \item{OFF_WATER_DEPTH}{}
#' \item{OFF_ACCIDENT_ORIGIN}{}
#' \item{OFFSHORE_STATE_ABBREVIATION}{}
#' \item{OFF_INSTATE_AREA}{}
#' \item{OFF_INSTATE_BLOCK}{}
#' \item{OFFSHORE_COUNTY_NAME}{}
#' \item{OFF_OCS_AREA}{}
#' \item{OFF_OCS_BLOCK}{}
#' \item{OFF_AREA_ACCIDENT_TYPE}{}
#' \item{PIPE_FACILITY_TYPE}{}
#' \item{system}{Part of system involved in accident.}
#' \item{SYSTEM_SUBPART_INVOLVED}{}
#' \item{item}{Item involved in accident.}
#' \item{PIPE_TYPE}{}
#' \item{PIPE_DIAMETER}{}
#' \item{PIPE_WALL_THICKNESS}{}
#' \item{PIPE_SMYS}{}
#' \item{PIPE_SPECIFICATION}{}
#' \item{PIPE_SEAM_TYPE}{}
#' \item{PIPE_SEAM_DETAILS}{}
#' \item{PIPE_MANUFACTURER}{}
#' \item{PIPE_MANUFACTURE_YEAR}{}
#' \item{PIPE_COATING_TYPE}{}
#' \item{PIPE_COATING_DETAILS}{}
#' \item{WELD_SUBTYPE}{}
#' \item{WELD_DETAILS}{}
#' \item{VALVE_TYPE}{}
#' \item{VALVE_MAINLINE_TYPE}{}
#' \item{VALVE_MAINLINE_DETAILS}{}
#' \item{VALVE_MANUFACTURER}{}
#' \item{VALVE_MANUFACTURE_YEAR}{}
#' \item{TANK_VESSEL_SUBTYPE}{}
#' \item{ITEM_INVOLVED_DETAILS}{}
#' \item{TANK_VESSEL_DETAILS}{}
#' \item{installation_year}{Year item installed that involved in accident.}
#' \item{MATERIAL_INVOLVED}{}
#' \item{MATERIAL_DETAILS}{}
#' \item{RELEASE_TYPE}{}
#' \item{PUNCTURE_AXIAL}{}
#' \item{PUNCTURE_CIRCUM}{}
#' \item{LEAK_TYPE}{}
#' \item{LEAK_TYPE_OTHER}{}
#' \item{RUPTURE_ORIENT}{}
#' \item{RUPTURE_DETAILS}{}
#' \item{RUPTURE_WIDTH}{}
#' \item{RUPTURE_LENGTH}{}
#' \item{RELEASE_TYPE_DETAILS}{}
#' \item{WILDLIFE_IMPACT_IND}{}
#' \item{FISH_AQUATIC_IMPACT_IND}{}
#' \item{BIRDS_IMPACT_IND}{}
#' \item{TERRESTRIAL_IMPACT_IND}{}
#' \item{SOIL_CONTAMINATION}{}
#' \item{LONG_TERM_ASSESSMENT}{}
#' \item{REMEDIATION_IND}{}
#' \item{surface_water_remediation}{Need for surface water remediation anticipated?}
#' \item{groundwater_remediation}{Need for groundwater remediation anticipated?}
#' \item{soil_remediation}{Need for soil remediation anticipated?}
#' \item{vegetation_remediation}{Need for vegetation remediation anticipated?}
#' \item{wildlife_remediation}{Need for wildlife remediation anticipated?}
#' \item{water_contamination}{Water Contamination.}
#' \item{OCEAN_SEAWATER_IND}{}
#' \item{SURFACE_CONTAM_IND}{}
#' \item{GROUNDWATER_CONTAM_IND}{}
#' \item{DRINKING_WATER_CONTAM_IND}{}
#' \item{PRIVATE_WELL_CONTAM_IND}{}
#' \item{PUBLIC_WATER_CONTAM_IND}{}
#' \item{AMOUNT_RELEASED}{}
#' \item{REL_WATER_NAME}{}
#' \item{COULD_BE_HCA}{}
#' \item{COMMODITY_REACHED_HCA}{}
#' \item{COMMERCIALLY_NAV_IND}{}
#' \item{COMMERCIALLY_NAV_YES_NO}{}
#' \item{HIGH_POP_IND}{}
#' \item{HIGH_POP_YES_NO}{}
#' \item{OTHER_POP_IND}{}
#' \item{OTHER_POP_YES_NO}{}
#' \item{USA_DRINKING_IND}{}
#' \item{USA_DRINKING_YES_NO}{}
#' \item{USA_ECOLOGICAL_IND}{}
#' \item{USA_ECOLOGICAL_YES_NO}{}
#' \item{EST_COST_OPER_PAID}{}
#' \item{EST_COST_GAS_RELEASED}{}
#' \item{EST_COST_PROP_DAMAGE}{}
#' \item{EST_COST_EMERGENCY}{}
#' \item{EST_COST_ENVIRONMENTAL}{}
#' \item{EST_COST_OTHER}{}
#' \item{EST_COST_OTHER_DETAILS}{}
#' \item{cost}{Total estimated property damage (sum of above).}
#' \item{cost_1984}{Converted Property Damage to Year 1984 dollars.}
#' \item{TOTAL_COST_CURRENT}{}
#' \item{ACCIDENT_PSIG}{}
#' \item{MOP_PSIG}{}
#' \item{ACCIDENT_PRESSURE}{}
#' \item{PRESSURE_RESTRICTION_IND}{}
#' \item{EXCEED_RESTRICTION_IND}{}
#' \item{PHMSA_RESTRICTION_IND}{}
#' \item{PART_C_QUESTION_2_IND}{}
#' \item{UPSTREAM_VALVE_TYPE_IND}{}
#' \item{DOWNSTREAM_VALVE_TYPE_IND}{}
#' \item{LENGTH_SEGMENT_ISOLATED}{}
#' \item{INTERNAL_INSPECTION_IND}{}
#' \item{DIAMETER_CHANGE_IND}{}
#' \item{UNSUITABLE_MAINLINE_IND}{}
#' \item{TIGHT_MITERED_IND}{}
#' \item{OTHER_RESTRICTIONS_IND}{}
#' \item{EXTRA_THICK_WALL_IND}{}
#' \item{OTHER_INSPECTION_IND}{}
#' \item{INTERNAL_INSPECTION_DETAILS}{}
#' \item{OPERATION_COMPLICATIONS_IND}{}
#' \item{EXCESSIVE_DEBRIS_IND}{}
#' \item{LOW_OP_PRESSURE_IND}{}
#' \item{LOW_FLOW_IND}{}
#' \item{INCOMPAT_COMMOD_IND}{}
#' \item{OTHER_COMPLICATIONS_IND}{}
#' \item{INSPECT_COMP_DETAILS}{}
#' \item{PIPELINE_FUNCTION}{}
#' \item{SCADA_IN_PLACE_IND}{}
#' \item{SCADA_OPERATING_IND}{}
#' \item{SCADA_FUNCTIONAL_IND}{}
#' \item{SCADA_DETECTION_IND}{}
#' \item{SCADA_CONF_IND}{}
#' \item{CPM_IN_PLACE_IND}{}
#' \item{CPM_OPERATING_IND}{}
#' \item{CPM_FUNCTIONAL_IND}{}
#' \item{CPM_DETECTION_IND}{}
#' \item{CPM_CONF_IND}{}
#' \item{ACCIDENT_IDENTIFIER}{}
#' \item{ACCIDENT_DETAILS}{}
#' \item{OPERATOR_TYPE}{}
#' \item{INVESTIGATION_STATUS}{}
#' \item{INVESTIGATION_STATUS_DETAILS}{}
#' \item{INVEST_SCHEDULE_IND}{}
#' \item{INVEST_NO_SCHEDULE_IND}{}
#' \item{INVEST_NO_SCHEDULE_IND_DETAILS}{}
#' \item{INVEST_NO_CONTROL_ROOM_IND}{}
#' \item{INVEST_NO_CONTROLLER_IND}{}
#' \item{INVEST_INCORRECT_ACTION_IND}{}
#' \item{INVEST_FATIGUE_IND}{}
#' \item{INVEST_INCORRECT_PROCEDURE_IND}{}
#' \item{INVEST_INCORRECT_CONTROL_IND}{}
#' \item{INVEST_MAINT_IND}{}
#' \item{INVEST_OTHER_IND}{}
#' \item{INVEST_OTHER_IND_DETAILS}{}
#' \item{EMPLOYEE_DRUG_TEST_IND}{}
#' \item{CONTRACTOR_DRUG_TEST_IND}{}
#' \item{NUM_EMPLOYEES_TESTED}{}
#' \item{NUM_EMPLOYEES_FAILED}{}
#' \item{NUM_CONTRACTORS_TESTED}{}
#' \item{NUM_CONTRACTORS_FAILED}{}
#' \item{MAP_CAUSE}{Cause, coded by PHMSA.}
#' \item{CAUSE_DETAILS}{}
#' \item{INTERNAL_EXTERNAL}{}
#' \item{VISUAL_EXAM_RESULTS}{}
#' \item{VISUAL_EXAM_DETAILS}{}
#' \item{GALVANIC_CORROSION_IND}{}
#' \item{ATMOSPHERE_CORROSION_IND}{}
#' \item{STRAY_CURRENT_CORROSION_IND}{}
#' \item{MICROBIOLOGICAL_CORROSION_IND}{}
#' \item{SELECTIVE_SEAM_CORROSION_IND}{}
#' \item{OTHER_CORROSION_IND}{}
#' \item{CORROSION_TYPE_DETAILS}{}
#' \item{FIELD_EXAM_BASIS_IND}{}
#' \item{METALLURGICAL_BASIS_IND}{}
#' \item{OTHER_BASIS_IND}{}
#' \item{CORROSION_BASIS_DETAILS}{}
#' \item{UNDERGROUND_LOCATION}{}
#' \item{UNDER_CATHODIC_PROTECTION_IND}{}
#' \item{CATHODIC_PRO_START_YEAR}{}
#' \item{SHIELDING_EVIDENT}{}
#' \item{CATHODIC_SURVEY_TYPE}{}
#' \item{CP_ANNUAL_SURVEY_IND}{}
#' \item{CLOSE_INTERVAL_SURVEY_IND}{}
#' \item{OTHER_CP_SURVEY_IND}{}
#' \item{CP_ANNUAL_SURVEY_YEAR}{}
#' \item{CLOSE_INTERVAL_SURVEY_YEAR}{}
#' \item{OTHER_CP_SURVEY_YEAR}{}
#' \item{EXTERNALLY_COATED}{}
#' \item{PRIOR_DAMAGE}{}
#' \item{INT_VISUAL_EXAM_RESULTS}{}
#' \item{INT_VISUAL_EXAM_DETAILS}{}
#' \item{INT_CORROSIVE_COMMODITY_IND}{}
#' \item{INT_WATER_ACID_IND}{}
#' \item{INT_MICROBIOLOGICAL_IND}{}
#' \item{INT_EROSION_IND}{}
#' \item{INT_OTHER_CORROSION_IND}{}
#' \item{INT_CORROSION_TYPE_DETAILS}{}
#' \item{INT_FIELD_EXAM_BASIS_IND}{}
#' \item{INT_METALLURGICAL_BASIS_IND}{}
#' \item{INT_OTHER_BASIS_IND}{}
#' \item{INT_CORROSION_BASIS_DETAILS}{}
#' \item{INT_LOW_POINT_PIPE_LOC_IND}{}
#' \item{INT_ELBOW_LOC_IND}{}
#' \item{INT_OTHER_LOC_IND}{}
#' \item{CORROSION_LOCATION_DETAILS}{}
#' \item{CORROSION_INHIBITORS}{}
#' \item{CORROSION_LINING}{}
#' \item{CLEANING_DEWATERING}{}
#' \item{CORROSION_COUPONS}{}
#' \item{API_STD_OUT_OF_SERVICE_IND}{}
#' \item{API_STD_OUT_OF_SERVICE_YEAR}{}
#' \item{API_STD_IN_SERVICE_IND}{}
#' \item{API_STD_IN_SERVICE_YEAR}{}
#' \item{COR_INSP_TOOL_COLL_IND}{}
#' \item{COR_MAGNETIC_FLUX_LEAKAGE_IND}{}
#' \item{COR_MAG_FLUX_LEAKAGE_YEAR}{}
#' \item{COR_ULTRASONIC_IND}{}
#' \item{COR_ULTRASONIC_YEAR}{}
#' \item{COR_GEOMETRY_IND}{}
#' \item{COR_GEOMETRY_YEAR}{}
#' \item{COR_CALIPER_IND}{}
#' \item{COR_CALIPER_YEAR}{}
#' \item{COR_CRACK_IND}{}
#' \item{COR_CRACK_YEAR}{}
#' \item{COR_HARDSPOT_IND}{}
#' \item{COR_HARDSPOT_YEAR}{}
#' \item{COR_COMBINATION_TOOL_IND}{}
#' \item{COR_COMBINATION_TOOL_YEAR}{}
#' \item{COR_TRANSVERSE_FIELD_IND}{}
#' \item{COR_TRANSVERSE_FIELD_YEAR}{}
#' \item{COR_INSPECTION_OTHER_IND}{}
#' \item{COR_INSPECTION_OTHER_YEAR}{}
#' \item{COR_INSPECTION_OTHER_DETAILS}{}
#' \item{COR_HYDROTEST_CONDUCTED_IND}{}
#' \item{COR_HYDROTEST_CONDUCTED_YEAR}{}
#' \item{COR_HYDROTEST_PRESSURE}{}
#' \item{DIRECT_INSPECTION_TYPE}{}
#' \item{DIRECT_YES_DIG_YEAR}{}
#' \item{DIRECT_YES_NO_DIG_YEAR}{}
#' \item{COR_NON_DESTRUCTIVE_IND}{}
#' \item{COR_RADIOGRAPHY_IND}{}
#' \item{COR_RADIOGRAPHY_YEAR}{}
#' \item{COR_GUIDED_WAVE_IND}{}
#' \item{COR_GUIDED_WAVE_YEAR}{}
#' \item{COR_HANDHELD_ULTRA_IND}{}
#' \item{COR_HANDHELD_ULTRA_YEAR}{}
#' \item{COR_WET_MAGNETIC_IND}{}
#' \item{COR_WET_MAGNETIC_YEAR}{}
#' \item{COR_DRY_MAGNETIC_IND}{}
#' \item{COR_DRY_MAGNETIC_YEAR}{}
#' \item{COR_NON_DEST_OTHER_IND}{}
#' \item{COR_NON_DEST_OTHER_YEAR}{}
#' \item{COR_NON_DEST_DETAILS}{}
#' \item{NATURAL_FORCE_TYPE}{}
#' \item{EARTH_SUBTYPE}{}
#' \item{HEAVY_RAINS_SUBTYPE}{}
#' \item{LIGHTNING_SUBTYPE}{}
#' \item{TEMPERATURE_SUBTYPE}{}
#' \item{NF_OTHER_DETAILS}{}
#' \item{NF_EXTREME_WEATHER_IND}{}
#' \item{NF_HURRICANE_IND}{}
#' \item{NF_TROPICAL_STORM_IND}{}
#' \item{NF_TORNADO_IND}{}
#' \item{NF_OTHER_IND}{}
#' \item{NF_EXTREME_WEATHER_DETAILS}{}
#' \item{excavation_damage_type}{Type of damage caused by excavation party.}
#' \item{EX_INSPECT_TOOL_COLLECTED_IND}{}
#' \item{EX_MAGNETIC_FLUX_LEAKAGE_IND}{}
#' \item{EX_MAGNETIC_FLUX_LEAKAGE_YEAR}{}
#' \item{EX_ULTRASONIC_IND}{}
#' \item{EX_ULTRASONIC_YEAR}{}
#' \item{EX_GEOMETRY_IND}{}
#' \item{EX_GEOMETRY_YEAR}{}
#' \item{EX_CALIPER_IND}{}
#' \item{EX_CALIPER_YEAR}{}
#' \item{EX_CRACK_IND}{}
#' \item{EX_CRACK_YEAR}{}
#' \item{EX_HARDSPOT_IND}{}
#' \item{EX_HARDSPOT_YEAR}{}
#' \item{EX_COMBINATION_TOOL_IND}{}
#' \item{EX_COMBINATION_TOOL_YEAR}{}
#' \item{EX_TRANSVERSE_FIELD_IND}{}
#' \item{EX_TRANSVERSE_FIELD_YEAR}{}
#' \item{EX_INSPECTION_OTHER_IND}{}
#' \item{EX_INSPECTION_OTHER_YEAR}{}
#' \item{EX_INSPECTION_OTHER_DETAILS}{}
#' \item{EX_BEFORE_DAMAGE}{}
#' \item{EX_HYDROTEST_CONDUCTED_IND}{}
#' \item{EX_HYDROTEST_CONDUCTED_YEAR}{}
#' \item{EX_HYDROTEST_PRESSURE}{}
#' \item{EX_DIRECT_INSPECTION_TYPE}{}
#' \item{EX_DIRECT_YES_DIG_YEAR}{}
#' \item{EX_DIRECT_YES_NO_DIG_YEAR}{}
#' \item{EX_NON_DESTRUCTIVE_IND}{}
#' \item{EX_RADIOGRAPHY_IND}{}
#' \item{EX_RADIOGRAPHY_YEAR}{}
#' \item{EX_GUIDED_WAVE_IND}{}
#' \item{EX_GUIDED_WAVE_YEAR}{}
#' \item{EX_HANDHELD_ULTRA_IND}{}
#' \item{EX_HANDHELD_ULTRA_YEAR}{}
#' \item{EX_WET_MAGNETIC_IND}{}
#' \item{EX_WET_MAGNETIC_YEAR}{}
#' \item{EX_DRY_MAGNETIC_IND}{}
#' \item{EX_DRY_MAGNETIC_YEAR}{}
#' \item{EX_NON_DEST_OTHER_IND}{}
#' \item{EX_NON_DEST_OTHER_YEAR}{}
#' \item{EX_NON_DEST_OTHER_DETAILS}{}
#' \item{PRIOR_NOTIFICATION_IND}{}
#' \item{ONE_CALL_SYSTEM_IND}{}
#' \item{EXCAVATOR_IND}{}
#' \item{CONTRACTOR_IND}{}
#' \item{LANDOWNER_IND}{}
#' \item{NOTIFY_CGA_DIRT}{}
#' \item{PUBLIC_ROW_IND}{}
#' \item{PUBLIC_SUBTYPE}{}
#' \item{PRIVATE_ROW_IND}{}
#' \item{PRIVATE_SUBTYPE}{}
#' \item{PIPELINE_EASEMENT_ROW_IND}{}
#' \item{POWER_TRANSMISSION_ROW_IND}{}
#' \item{RAILROAD_ROW_IND}{}
#' \item{PUBLIC_UTIL_EASEMENT_ROW_IND}{}
#' \item{FEDERAL_LAND_ROW_IND}{}
#' \item{DATA_NOT_COLLECTED_ROW_IND}{}
#' \item{UNKNOWN_ROW_IND}{}
#' \item{EXCAVATOR_TYPE}{}
#' \item{EXCAVATOR_EQUIPMENT}{}
#' \item{WORK_PERFORMED}{}
#' \item{ONE_CALL_NOTIFIED_IND}{}
#' \item{ONE_CALL_TICKET_NUM}{}
#' \item{ONE_CALL_CENTER_NAME}{}
#' \item{LOCATOR_TYPE}{}
#' \item{VISIBLE_MARKS}{}
#' \item{FACILITIES_MARKED}{}
#' \item{SERVICE_INTERRUPTION}{}
#' \item{SERVICE_INTERRUPTION_HOURS}{}
#' \item{ROOT_CAUSE}{}
#' \item{ONE_CALL_SUBTYPE}{}
#' \item{LOCATING_SUBTYPE}{}
#' \item{EXCAVATION_SUBTYPE}{}
#' \item{ROOT_CAUSE_OTHER}{}
#' \item{OUTSIDE_FORCE_TYPE}{}
#' \item{VEHICLE_SUBTYPE}{}
#' \item{OSF_HURRICANE_IND}{}
#' \item{OSF_TROPICAL_STORM_IND}{}
#' \item{OSF_TORNADO_IND}{}
#' \item{OSF_HEAVY_RAINS_IND}{}
#' \item{OSF_OTHER_WEATHER_IND}{}
#' \item{OSF_OTHER_WEATHER_DETAILS}{}
#' \item{OSF_INSPECT_TOOL_COLLECTED_IND}{}
#' \item{OSF_MAGNETIC_FLUX_LEAKAGE_IND}{}
#' \item{OSF_MAGNETIC_FLUX_LEAKAGE_YEAR}{}
#' \item{OSF_ULTRASONIC_IND}{}
#' \item{OSF_ULTRASONIC_YEAR}{}
#' \item{OSF_GEOMETRY_IND}{}
#' \item{OSF_GEOMETRY_YEAR}{}
#' \item{OSF_CALIPER_IND}{}
#' \item{OSF_CALIPER_YEAR}{}
#' \item{OSF_CRACK_IND}{}
#' \item{OSF_CRACK_YEAR}{}
#' \item{OSF_HARDSPOT_IND}{}
#' \item{OSF_HARDSPOT_YEAR}{}
#' \item{OSF_COMBINATION_TOOL_IND}{}
#' \item{OSF_COMBINATION_TOOL_YEAR}{}
#' \item{OSF_TRANSVERSE_FIELD_IND}{}
#' \item{OSF_TRANSVERSE_FIELD_YEAR}{}
#' \item{OSF_INSPECTION_OTHER_IND}{}
#' \item{OSF_INSPECTION_OTHER_YEAR}{}
#' \item{OSF_INSPECTION_OTHER_DETAILS}{}
#' \item{OSF_BEFORE_DAMAGE}{}
#' \item{OSF_HYDROTEST_CONDUCTED_IND}{}
#' \item{OSF_HYDROTEST_CONDUCTED_YEAR}{}
#' \item{OSF_HYDROTEST_PRESSURE}{}
#' \item{OSF_DIRECT_INSPECTION_TYPE}{}
#' \item{OSF_DIRECT_YES_DIG_YEAR}{}
#' \item{OSF_DIRECT_YES_NO_DIG_YEAR}{}
#' \item{OSF_NON_DESTRUCTIVE_IND}{}
#' \item{OSF_RADIOGRAPHY_IND}{}
#' \item{OSF_RADIOGRAPHY_YEAR}{}
#' \item{OSF_GUIDED_WAVE_IND}{}
#' \item{OSF_GUIDED_WAVE_YEAR}{}
#' \item{OSF_HANDHELD_ULTRA_IND}{}
#' \item{OSF_HANDHELD_ULTRA_YEAR}{}
#' \item{OSF_WET_MAGNETIC_IND}{}
#' \item{OSF_WET_MAGNETIC_YEAR}{}
#' \item{OSF_DRY_MAGNETIC_IND}{}
#' \item{OSF_DRY_MAGNETIC_YEAR}{}
#' \item{OSF_NON_DEST_OTHER_IND}{}
#' \item{OSF_NON_DEST_OTHER_YEAR}{}
#' \item{OSF_NON_DEST_DETAILS}{}
#' \item{INTENTIONAL_SUBTYPE}{}
#' \item{INTENTIONAL_DETAILS}{}
#' \item{OSF_OTHER_DETAILS}{}
#' \item{FIELD_EXAM_IND}{}
#' \item{METALLURGICAL_IND}{}
#' \item{OTHER_ANALYSIS_IND}{}
#' \item{OTHER_ANALYSIS_DETAILS}{}
#' \item{STILL_UNDER_INVEST_IND}{}
#' \item{FAILURE_TYPE}{}
#' \item{FATIGUE_VIBR_RELATED_1}{}
#' \item{FAILURE_SUBTYPE_1}{}
#' \item{FATIGUE_VIBR_RELATED_OTHER_1}{}
#' \item{MECHANICAL_STRESS_1}{}
#' \item{OTHER_FACTOR_1}{}
#' \item{OTHER_FACTOR_DETAILS_1}{}
#' \item{FATIGUE_VIBR_RELATED_2}{}
#' \item{FAILURE_SUBTYPE_2}{}
#' \item{FATIGUE_VIBR_RELATED_OTHER_2}{}
#' \item{MECHANICAL_STRESS_2}{}
#' \item{OTHER_FACTOR_2}{}
#' \item{OTHER_FACTOR_DETAILS_2}{}
#' \item{STRESS_SUBTYPE}{}
#' \item{STRESS_DETAILS}{}
#' \item{ADDITIONAL_DENT_IND}{}
#' \item{ADDITIONAL_GOUGE_IND}{}
#' \item{ADDITIONAL_PIPE_BEND_IND}{}
#' \item{ADDITIONAL_ARC_BURN_IND}{}
#' \item{ADDITIONAL_CRACK_IND}{}
#' \item{ADDITIONAL_LACK_FUSION_IND}{}
#' \item{ADDITIONAL_LAMINATION_IND}{}
#' \item{ADDITIONAL_BUCKLE_IND}{}
#' \item{ADDITIONAL_WRINKLE_IND}{}
#' \item{PWF_ADDL_MISALIGNMENT_IND}{}
#' \item{ADDITIONAL_BURNT_STEEL_IND}{}
#' \item{PWF_ADDITIONAL_OTHER_IND}{}
#' \item{PWF_ADDITIONAL_OTHER_DETAILS}{}
#' \item{PWF_INSP_TOOL_COLLECTED_IND}{}
#' \item{PWF_MAGNETIC_FLUX_LEAKAGE_IND}{}
#' \item{PWF_MAG_FLUX_LEAKAGE_YEAR}{}
#' \item{PWF_ULTRASONIC_IND}{}
#' \item{PWF_ULTRASONIC_YEAR}{}
#' \item{PWF_GEOMETRY_IND}{}
#' \item{PWF_GEOMETRY_YEAR}{}
#' \item{PWF_CALIPER_IND}{}
#' \item{PWF_CALIPER_YEAR}{}
#' \item{PWF_CRACK_IND}{}
#' \item{PWF_CRACK_YEAR}{}
#' \item{PWF_HARDSPOT_IND}{}
#' \item{PWF_HARDSPOT_YEAR}{}
#' \item{PWF_COMBINATION_TOOL_IND}{}
#' \item{PWF_COMBINATION_TOOL_YEAR}{}
#' \item{PWF_TRANSVERSE_FIELD_IND}{}
#' \item{PWF_TRANSVERSE_FIELD_YEAR}{}
#' \item{PWF_INSPECTION_OTHER_IND}{}
#' \item{PWF_INSPECTION_OTHER_YEAR}{}
#' \item{PWF_INSPECTION_OTHER_DETAILS}{}
#' \item{PWF_HYDROTEST_CONDUCTED_IND}{}
#' \item{PWF_HYDROTEST_CONDUCTED_YEAR}{}
#' \item{PWF_HYDROTEST_PRESSURE}{}
#' \item{PWF_DIRECT_INSPECTION_TYPE}{}
#' \item{PWF_DIRECT_YES_DIG_YEAR}{}
#' \item{PWF_DIRECT_YES_NO_DIG_YEAR}{}
#' \item{PWF_NON_DEST_IND}{}
#' \item{PWF_RADIOGRAPHY_IND}{}
#' \item{PWF_RADIOGRAPHY_YEAR}{}
#' \item{PWF_GUIDED_WAVE_IND}{}
#' \item{PWF_GUIDED_WAVE_YEAR}{}
#' \item{PWF_HANDHELD_ULTRA_IND}{}
#' \item{PWF_HANDHELD_ULTRA_YEAR}{}
#' \item{PWF_WET_MAGNETIC_IND}{}
#' \item{PWF_WET_MAGNETIC_YEAR}{}
#' \item{PWF_DRY_MAGNETIC_IND}{}
#' \item{PWF_DRY_MAGNETIC_YEAR}{}
#' \item{PWF_NON_DEST_OTHER_IND}{}
#' \item{PWF_NON_DEST_OTHER_YEAR}{}
#' \item{PWF_NON_DEST_OTHER_DETAILS}{}
#' \item{EQ_FAILURE_TYPE}{}
#' \item{CONTROL_VALVE_IND}{}
#' \item{INSTRUMENTATION_IND}{}
#' \item{SCADA_IND}{}
#' \item{COMMUNICATIONS_IND}{}
#' \item{BLOCK_VALVE_IND}{}
#' \item{CHECK_VALVE_IND}{}
#' \item{RELIEF_VALVE_IND}{}
#' \item{POWER_FAILURE_IND}{}
#' \item{STOPPLE_CONTROL_FITTING_IND}{}
#' \item{ESD_SYSTEM_FAILURE_IND}{}
#' \item{OTHER_CONTROL_RELIEF_IND}{}
#' \item{OTHER_CONTROL_RELIEF_DETAILS}{}
#' \item{OTHER_PUMP_IND}{}
#' \item{OTHER_PUMP_DETAILS}{}
#' \item{OTHER_STRIPPED_IND}{}
#' \item{OTHER_STRIPPED_DETAILS}{}
#' \item{OTHER_NON_THREADED_IND}{}
#' \item{OTHER_NON_THREADED_DETAILS}{}
#' \item{FAILURE_DETAILS}{}
#' \item{ADDITIONAL_VIBRATION_IND}{}
#' \item{ADDITIONAL_OVERPRESSURE_IND}{}
#' \item{ADDITIONAL_SUPPORT_IND}{}
#' \item{ADDITIONAL_DEFECT_IND}{}
#' \item{ADDITIONAL_ELECTRICITY_IND}{}
#' \item{ADDITIONAL_INSTALLATION_IND}{}
#' \item{ADDITIONAL_MISMATCH_IND}{}
#' \item{ADDITIONAL_DISSIMILAR_IND}{}
#' \item{ADDITIONAL_BREAKDOWN_IND}{}
#' \item{ADDITIONAL_VALVE_IND}{}
#' \item{ADDITIONAL_ALARM_IND}{}
#' \item{IEF_ADDL_MISALIGNMENT_IND}{}
#' \item{ADDITIONAL_THERMAL_IND}{}
#' \item{EQ_ADDITIONAL_OTHER_IND}{}
#' \item{EQ_ADDITIONAL_OTHER_DETAILS}{}
#' \item{OPERATION_TYPE}{}
#' \item{OVERFLOW_OTHER_IND}{}
#' \item{OVERFLOW_OTHER_DETAILS}{}
#' \item{OPERATION_DETAILS}{}
#' \item{RELATED_INADEQUATE_PROC_IND}{}
#' \item{RELATED_NO_PROC_IND}{}
#' \item{RELATED_FAILURE_FOLLOW_IND}{}
#' \item{RELATED_OTHER_IND}{}
#' \item{OPERATION_RELATED_DETAILS}{}
#' \item{CATEGORY_TYPE}{}
#' \item{OPERATOR_QUALIFICATION_IND}{}
#' \item{QUALIFIED_INDIVIDUALS}{}
#' \item{OTHER_TYPE}{}
#' \item{MISC_DETAILS}{}
#' \item{UNKNOWN_SUBTYPE}{}
#' \item{PREPARER_NAME}{}
#' \item{PREPARER_TITLE}{}
#' \item{PREPARER_EMAIL}{}
#' \item{PREPARER_TELEPHONE}{}
#' \item{PREPARER_FAX}{}
#' \item{PREPARED_DATE}{}
#' \item{AUTHORIZER_NAME}{}
#' \item{AUTHORIZER_TITLE}{}
#' \item{AUTHORIZER_TELEPHONE}{}
#' \item{AUTHORIZER_EMAIL}{}
#' \item{narrative}{Written description of the incident.}
#' \item{EST_COST_OPER_PAID_CURRENT}{}
#' \item{EST_COST_GAS_RELEASED_CURRENT}{}
#' \item{EST_COST_PROP_DAMAGE_CURRENT}{}
#' \item{EST_COST_EMERGENCY_CURRENT}{}
#' \item{EST_COST_ENVIRONMENTAL_CURRENT}{}
#' \item{EST_COST_OTHER_CURRENT}{}
#' \item{cause}{Cause of the incident.}
#' \item{subcause}{Subcause of the incident, coded by PHMSA.}
#' \item{SPILL_TYPE_CATEGORY}{}
#' \item{date}{Date of the spill.}
#' \item{state}{State of incidents (for offshore, the state of nearby coast).}
#' \item{manufacture_year}{Year that the failed pipe or valve was manufactured.}
#' }
#' @examples
#' \dontrun{
#' incidents_2010
#' }
"incidents_2010"
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.