#' Minenergo-325. Test bench of district heating network
#'
#' Data describes a virtual test bench of branched district heating network
#' by exposing parameters associated with
#' \href{https://docs.cntd.ru/document/902148459}{Minenergo Order 325}.
#' They treat data as a snapshot of network state and use it
#' primarily for static thermal-hydraulic computations and topology effects.
#'
#' The test bench has the next configuration:
#'
#' \figure{m325nxdata.png}
#'
#' As it may be seen from the figure there is a particularity in topology of
#' the provided directed graph: each node has only single ancestor. Hence one
#' of isomorphic representation of such directed graph is a
#' \code{\link{data.frame}} in which each row describes a node along with its
#' incoming edge and each column contains an attribute value for that node or
#' an attribute value for its incoming edge.
#'
#' Since they deal with incoming edges and hence nodes are all flow acceptors
#' the natural enumeration of nodes is by acceptor id.
#'
#' Note that to leverage
#' \href{https://cran.r-project.org/package=igraph}{igraph}
#' functionality for plotting there is a zero sender of flow.
#'
#' @family Minenergo
#'
#' @format A data frame with 22 rows (number of nodes and incoming edges) and 15 variables:
#' \describe{
#' \item{sender}{
#' An identifier of node which heat carrier flows out.
#' Type: any type that can be painlessly coerced to character
#' by \code{\link{as.character}}.
#' }
#'
#' \item{acceptor}{
#' An identifier of node which heat carrier flows in. According to topology
#' of test bench considered this identifier should be unique for every row.
#' Type: any type that can be painlessly coerced to
#' character by \code{\link{as.character}}.
#' }
#'
#' \item{temperature}{
#' Snapshot of thermal-hydraulic regime state: temperature of heat carrier
#' (water) sensor-measured on terminal acceptor node, [\emph{°C}].
#' Type: \code{\link{assert_double}}. \code{NA}s are introduced for nodes
#' without temperature sensor.
#' }
#'
#' \item{pressure}{
#' Snapshot of thermal-hydraulic regime state:
#' sensor-measured
#' \href{https://en.wikipedia.org/wiki/Pressure_measurement#Absolute}{absolute pressure}
#' of heat carrier (water) inside the pipe (i.e. acceptor's incoming edge),
#' [\emph{MPa}].
#' Type: \code{\link{assert_double}}. \code{NA}s are introduced for nodes
#' without pressure sensor.
#' }
#'
#' \item{flow_rate}{
#' Snapshot of thermal-hydraulic regime state:
#' sensor-measured amount of heat carrier (water) on terminal node that is
#' transferred by pipe (i.e. acceptor's incoming edge) during a period,
#' [\emph{ton/hour}]. Type: \code{\link{assert_double}}.
#' \code{NA}s are introduced for nodes without flow rate sensor.
#' }
#'
#' \item{d}{
#' internal diameter of pipe (i.e.diameter of acceptor's incoming edge),
#' [\emph{m}].
#' Type: \code{\link{assert_double}}.
#' }
#'
#' \item{len}{
#' pipe length (i.e. length of acceptor's incoming edge), [\emph{m}].
#' Type: \code{\link{assert_double}}.
#' }
#'
#' \item{year}{
#' year when the pipe (i.e. acceptor's incoming edge) is put in operation after
#' laying or total overhaul.
#' Type: \code{\link{assert_integerish}}.
#' }
#'
#' \item{insulation}{
#' identifier of insulation that covers the exterior of pipe (i.e. acceptor's
#' incoming edge):
#' \describe{
#' \item{\code{0}}{no insulation}
#' \item{\code{1}}{foamed polyurethane or analogue}
#' \item{\code{2}}{polymer concrete}
#' }
#' Type: \code{\link{assert_integerish}}.
#' }
#'
#' \item{laying}{
#' type of pipe laying depicting the position of pipe in space. Only five
#' types of pipe laying are considered:
#' \itemize{
#' \item \code{air},
#' \item \code{channel},
#' \item \code{room},
#' \item \code{tunnel},
#' \item \code{underground}.
#' }
#' Type: \code{\link{assert_character}}.
#' }
#'
#' \item{beta}{
#' logical indicator: should they consider additional heat loss of fittings
#' located on this pipe (i.e. acceptor's incoming edge)?
#' Type: \code{\link{assert_logical}}.
#' }
#'
#' \item{exp5k}{
#' logical indicator for regime of pipe (i.e. acceptor's incoming edge): if
#' \code{TRUE} pipe is operated more that \code{5000} hours per year.
#' Type: \code{\link{assert_logical}}.
#' }
#'
#' \item{roughness}{
#' roughness of internal wall of pipe (i.e. acceptor's incoming edge),
#' [\emph{m}].
#' Type: \code{\link{assert_double}}.
#' }
#'
#' \item{inlet}{
#' elevation of pipe inlet, [\emph{m}].
#' Type: \code{\link{assert_double}}.
#' }
#'
#' \item{outlet}{
#' elevation of pipe outlet, [\emph{m}].
#' Type: \code{\link{assert_double}}.
#' }
#'}
#'
#' @examples
#' library(pipenostics)
#'
#' # Do not hesitate to use `data.table` and `igraph` for larger chunks of network.
#'
#' # Check for declared topology isomorphism:
#' stopifnot(
#' all(!duplicated(m325nxdata$acceptor))
#' )
#'
#' # Do all terminal nodes have sensor-measured regime parameters?:
#' terminal_nodes <- subset(m325nxdata, !(acceptor %in% sender))
#' stopifnot(
#' all(!is.na(subset(terminal_nodes, select = c(temperature, pressure, flow_rate))))
#' )
#'
"m325nxdata"