Function to calculate the number of cases needed for an ROC analysis for a single test
1 | get_nc_roc(z = 1.96, precision = 0.05, vf)
|
z |
The z-score/z-value for a 95% confidence interval. Typical vaues
for |
precision |
The numeric value of the desired precision. Default is set at ±5% (0.05). |
vf |
Variance function of the area under the curve (AUC) for the received operator characteristic (ROC) surve sample size calculations |
A numeric value for the number of cases needed for an ROC analysis for a single test
Obuchowski NA. Fundamentals of clinical research for radiologists: ROC Analysis. American Journal of Roentgenology. 2005;184.
1 | get_nc_roc(z = 1.96, precision = 0.05, vf = 0.00991024)
|