Nothing
##' Interlaboratory Study
##'
##' It performs interlaboratory studies (ILS) to detect those laboratories that provide non-consistent results when comparing to others.
##' It permits to work simultaneously with various testing materials, from standard univariate, and functional data analysis (FDA) perspectives.
##' The univariate approach based on ASTM E691-08 consist of estimating the Mandel's h and k statistics to identify those laboratories
##' that provide more significant different results, testing also the presence of outliers by Cochran and Grubbs tests, Analysis of variance (ANOVA)
##' techniques are provided (F and Tuckey tests) to test differences in the testing variable means corresponding to test differences in means corresponding to differente laboratories per each material.
##' Taking into account the functional nature of data retrieved in analytical chemistry, applied physics and engineering (spectra, thermograms, etc.).
##' ILS package provides a FDA approach for functional Mandel's k and h statistics by smoothing bootstrap resampling of distribution.
##'
##' @name ILS
##'
##' @aliases ILS
##'
##' @docType package
##'
##' @title Interlaboratoty Study
##' @import lattice
##' @import multcomp
##' @import depthTools
##' @import fda.usc
##' @import MASS
##' @import stats
##' @import graphics
##' @importFrom grDevices terrain.colors
##' @importFrom utils setTxtProgressBar str txtProgressBar
##' @importFrom stats aov confint pf pt qf qt sd var
NULL
##' @title Glucose in Serum
##' @description
##' Dataset corresponding to serum glucose (measurements of glucose concentration in blood used to control diabetes) testing.
##' Eight laboratories conducted tests to five different blood samples tagged with different references, ranging them from low sugar content to very high.
##' Three replicates were obtained for each sample. It is retrieved from ASTM E 691 standard.
##' @name Glucose
##' @docType data
##' @format A data frame with 120 observations composed of the following 4 variables:
##' \describe{
##' \item{Glucose}{Glucose content in Serum.}
##' \item{Replicate}{Number of glucose measurement corresponding to each material.}
##' \item{Material}{Level of glucose, ranging from low content of sugar to very high level of glucose in blood.}
##' \item{Laboratory}{Laboratories conducted tests.}
##' }
##' @keywords datasets
##'
##' @references
##' ASTM E 691 (1999). Standard practice for conducting an interlaboratory study to determine
##' the precision of a test method. American Society for Testing and Materials. West Conshohocken, PA, USA.
##' @examples
##' library(ILS)
##' data(Glucose)
##' summary(Glucose)
##' attach(Glucose)
##' str(Glucose)
##' table(Replicate,Material,Laboratory)
##' table(Laboratory,Material)
##' st <- with(Glucose, tapply(Glucose, list(Material,Laboratory), mean))
##' st
##'
NULL
##' @title Dataset composed of the initial decomposition temperature (IDT) of different samples of Calcium Oxalate, obtained by 7 different laboratories
##'
##' @description Initial decomposition temperature (IDT) is a parameter defined by temperature at which a material loss 5\% of its weight
##' when it is heated using a constant rate. One hundred and five calcium oxalate samples were tested by thermogravimetric analysis (TG),
##' obtaining 105 TG curves from which the IDT is extracted. Summarizing, IDT dataset is composed of the IDT values of
##' calcium oxalate obtained by 7 different laboratories that analyze 15 oxalate samples each one.:
##' Laboratory 1 uses a simultaneous thermal analyzer (STA) with an old calibration program, Laboratory 2 to Laboratory 4 use a SDT simultaneous analyzer,
##' Laboratory 6 utilizes a SDT simultaneous analyzer with an old calibration, and Laboratory 7 uses a SDT simultaneous analyzer with a biased calibration
##' (2 degrees Celsius shifted from the zinc melting point).
##'
##' @name IDT
##'
##' @docType data
##'
##' @format Dataframe of dimension 105 x 44. The first column corresponds to IDT variable, the second (Sample) is the replicate number,
##' the third is the tested material (Material), and fourth is the laboratory.
##' \describe{
##' \item{IDT}{Initial decomposition temperature.}
##' \item{Sample}{The replicate number.}
##' \item{Run}{Tested material.}
##' \item{Laboratory}{Laboratories conducted tests.}
##' }
##'
##' @references
##' Naya, S., Tarrio-Saavedra. J., Lopez- Beceiro, J., Francisco Fernandez, M., Flores, M. and Artiaga, R. (2014),
##' "Statistical functional approach for interlaboratory studies with thermal data". Journal of Thermal Analysis and Calorimetry, 118,1229-1243.
##' @examples
##' library(ILS)
##' data(IDT)
##' summary(IDT)
##' attach(IDT)
##' str(IDT)
##' table(Sample,Run,Laboratory)
##' table(Laboratory,Run)
##' st <- with(IDT, tapply(IDT, list(Run,Laboratory), mean))
##' st
NULL
##' @title Thermogravimetry curves
##'
##' @description One hundred and five Calcium oxalate samples were tested by thermogravimetric (TG) analysis,
##' obtaining 105 TG curves that shows the mass loss of oxalate depending on time when samples are heated at a constant temperature rate.
##' Dataset is composed by fifteen TG curves of 1000 observations each of overall 7 different laboratories.
##' Laboratory 1 uses a simultaneous thermal analyzer (STA) with an old calibration program, Laboratory 2 to Laboratory 4
##' use a SDT simultaneous analyzer, Laboratory 6 utilizes a SDT simultaneous analyzer with an old calibration, and Laboratory 7
##' uses a SDT simultaneous analyzer with a biased calibration (2 degrees Celsius shifted from the zinc melting point).
##'
##' @name TG
##'
##' @docType data
##'
##' @format A 15 x 1000 x 7 dimension array , where each matrix consists of the 15 TG curves obtained testing 15 different oxalate samples,
##' and evaluated in 1000 different values of temperature. These 15 curves were obtained for each of the overall 7 laboratories that have performed the esperiments.
##' \describe{
##' \item{Vi}{Thermogravimetric.}
##' }
##'
##' @references
##' Naya, S., Tarrio-Saavedra. J., Lopez- Beceiro, J., Francisco Fernandez, M., Flores, M. and Artiaga, R. (2014),
##' "Statistical functional approach for interlaboratory studies with thermal data". Journal of Thermal Analysis and Calorimetry, 118,1229-1243.
##' @examples
##' library(ILS)
##' data(TG)
##' summary(TG)
##'
NULL
##' @title Differential Scanning Calorimetry curves
##'
##' @description 90 samples of calcium oxalate were analyzed by differential scanning calorimetry technique (DSC),
##' obtaining 90 DSC curves showing from an SDT device the difference of heat between a sample and an oxalate reference
##' value depending on the temperature that the samples are heated at a constant temperature rate.
##' The data set consists of 15 TG curves of 1000 observations from each of the 6 laboratories.
##' Laboratory 2 to Laboratory 4 uses the same simultaneous SDT analyzer in similar conditions,
##' Laboratory 6 uses a simultaneous SDT analyzer with an old calibration, and Laboratory 7 uses a simultaneous SDT
##' analyzer with a calibration (2 degrees Celsius displaced from the zinc melting point).
##'
##' @name DSC
##'
##' @docType data
##'
##' @format 5 x 1000 x 6 dimension array, where each matrix consists of the 15 DSC curves obtained by testing 15 different oxalate
##' samples, and evaluated at 1000 different temperature values. These 15 curves were obtained for each of the 6 laboratories that
##' performed the experiments.
##' \describe{
##' \item{Xi}{Differential Scanning Calorimetry curves.}
##' }
##'
##' @references
##' Naya, S., Tarrio-Saavedra. J., Lopez- Beceiro, J., Francisco Fernandez, M., Flores, M. and Artiaga, R. (2014),
##' "Statistical functional approach for interlaboratory studies with thermal data". Journal of Thermal Analysis and Calorimetry, 118,1229-1243.
##'
##' @examples
##' library(ILS)
##' data(DSC)
##' summary(DSC)
##'
NULL
Any scripts or data that you put into this service are public.
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.