Nothing
.BROScalc <- function(FUELTYPE, FFMC, BUI, WSV, FMC, SFC, PC, PDF, CC, CBH){
#############################################################################
# Description:
# Calculate the Back Fire Spread Rate.
#
# All variables names are laid out in the same manner as Forestry Canada
# Fire Danger Group (FCFDG) (1992). Development and Structure of the
# Canadian Forest Fire Behavior Prediction System." Technical Report
# ST-X-3, Forestry Canada, Ottawa, Ontario.
#
# Args:
# FUELTYPE: The Fire Behaviour Prediction FuelType
# FFMC: Fine Fuel Moisture Code
# BUI: Buildup Index
# WSV: Wind Speed Vector
# FMC: Foliar Moisture Content
# SFC: Surface Fuel Consumption
# PC: Percent Conifer
# PDF: Percent Dead Balsam Fir
# CC: Degree of Curing (just "C" in FCFDG 1992)
# CBH: Crown Base Height
# Returns:
# BROS: Back Fire Spread Rate
#
#############################################################################
#Eq. 46 (FCFDG 1992)
#Calculate the FFMC function from the ISI equation
m <- 147.27723 * (101 - FFMC) / (59.5 + FFMC)
#Eq. 45 (FCFDG 1992)
fF <- 91.9 * exp(-0.1386 * m) * (1.0 + (m**5.31) / 4.93e7)
#Eq. 75 (FCFDG 1992)
#Calculate the Back fire wind function
BfW <- exp(-0.05039 * WSV)
#Calculate the ISI associated with the back fire spread rate
#Eq. 76 (FCFDG 1992)
BISI <- 0.208 * BfW * fF
#Eq. 77 (FCFDG 1992)
#Calculate final Back fire spread rate
BROS <- .ROScalc(FUELTYPE, BISI, BUI, FMC, SFC, PC, PDF, CC, CBH)
return(BROS)
}