stupeflux | R Documentation |
Wrapper function for the Fluxible workflow. We recommand using the step-by-step workflow for more control over the process.
stupeflux(
raw_conc,
field_record,
f_datetime,
start_col,
end_col,
f_conc,
setup_volume,
measurement_length,
fit_type,
temp_air_col,
atm_pressure,
plot_area,
conc_unit,
flux_unit,
fixed_length = TRUE,
cols_keep = c(),
cols_ave = c(),
cols_sum = c(),
cols_med = c(),
ratio_threshold = 0.5,
time_diff = 0,
start_cut = 0,
end_cut = 0,
cz_window = 15,
b_window = 10,
a_window = 10,
roll_width = 15,
t_zero = 0,
force_discard = c(),
force_ok = c(),
force_zero = c(),
ambient_conc = 421,
error = 100,
pvalue_threshold = 0.3,
rsquared_threshold = 0.7,
rmse_threshold = 25,
cor_threshold = 0.5,
b_threshold = 1,
temp_air_unit = "celsius",
cut = TRUE,
slope_correction = TRUE
)
raw_conc |
dataframe of CO2 concentration measured continuously. Has to contain at least a datetime column in ymd_hms format and a gas concentration column as double. |
field_record |
dataframe recording which measurement happened when. Has to contain at least a column containing the start of each measurement, and any other column identifying the measurements. |
f_datetime |
datetime column in raw_conc (dmy_hms format) |
start_col |
start column in field_record (dmy_hms format) |
end_col |
end columne in field_record ( |
f_conc |
concentration column in raw_conc |
setup_volume |
volume of the flux chamber and instrument together in L, can also be a column in case it is a variable |
measurement_length |
length of the measurement (in seconds) from the start specified in the field_record |
fit_type |
|
temp_air_col |
column containing the air temperature used to calculate fluxes. Will be averaged with NA removed. |
atm_pressure |
atmospheric pressure, can be a constant (numerical) or a variable (column name) |
plot_area |
area of the plot in m^2, can also be a column in case it is a variable |
conc_unit |
unit in which the concentration of gas was measured
|
flux_unit |
unit in which the calculated flux will be
|
fixed_length |
if |
cols_keep |
columns to keep from the input to the output. Those columns need to have unique values for each flux, as distinct() is applied. |
cols_ave |
columns with values that should be averaged for each flux in the output. Note that NA are removed in mean calculation. |
cols_sum |
columns with values for which is sum is provided for each flux in the output. Note that NA are removed in sum calculation. |
cols_med |
columns with values for which is median is provided for each flux in the output. Note that NA are removed in median calculation. |
ratio_threshold |
ratio of gas concentration data points over length of measurement (in seconds) below which the measurement will be considered as not having enough data points to be considered for calculations |
time_diff |
time difference (in seconds) between the two datasets. Will be added to the datetime column of the raw_conc dataset. For situations where the time was not synchronized correctly. |
start_cut |
time to discard at the start of the measurements (in seconds) |
end_cut |
time to discard at the end of the measurements (in seconds) |
cz_window |
window used to calculate Cz, at the beginning of cut window
( |
b_window |
window to estimate b. It is an interval after tz where
it is assumed that the model fits the data perfectly
( |
a_window |
window at the end of the flux to estimate a
( |
roll_width |
width of the rolling mean for CO2 when looking for tz,
ideally same as cz_window ( |
t_zero |
time at which the slope should be calculated
(for |
force_discard |
vector of fluxIDs that should be discarded by the user's decision |
force_ok |
vector of fluxIDs for which the user wants to keep the calculated slope despite a bad quality flag |
force_zero |
vector of fluxIDs that should be replaced by zero by the user's decision |
ambient_conc |
ambient gas concentration in ppm at the site of measurement (used to detect measurement that started with a polluted setup) |
error |
error of the setup, defines a window outside of which the starting values indicate a polluted setup |
pvalue_threshold |
threshold of p-value below which the change of gas concentration over time is considered not significant (linear and quadratic fit) |
rsquared_threshold |
threshold of r squared value below which the linear model is considered an unsatisfactory fit (linear and quadratic fit) |
rmse_threshold |
threshold for the RMSE of each flux above which
the fit is considered unsatisfactory ( |
cor_threshold |
threshold for the correlation coefficient of
gas concentration with time below which the correlation
is considered not significant ( |
b_threshold |
threshold for the b parameter.
Defines a window with its opposite inside which the fit is
considered good enough ( |
temp_air_unit |
units in which air temperature was measured.
Has to be either |
cut |
if 'TRUE' (default), the measurements will be cut according to
'f_cut' before calculating fluxes. This has no influence on the flux itself
since the slope is provided from flux_fitting,
but it will influence the values of the columns in |
slope_correction |
logical. If |
a dataframe containing flux IDs, datetime of measurements' starts,
fluxes in
mmol * m-2 * h-1
or
micromol * m-2 * h-1
(f_flux
) according to flux_unit
, temperature average for each flux in
Kelvin (f_temp_ave
), the total volume of the setup for each measurement
(f_volume_setup
), the model used in
flux_fitting, any column specified in
cols_keep
, any column specified in cols_ave
with
their value averaged over the measurement after cuts and discarding NA.
Pedersen, A.R., Petersen, S.O., Schelde, K., 2010. A comprehensive approach to soil-atmosphere trace-gas flux estimation with static chambers. European Journal of Soil Science 61, 888–902. https://doi.org/10.1111/j.1365-2389.2010.01291.x
Hutchinson, G.L., Mosier, A.R., 1981. Improved Soil Cover Method for Field Measurement of Nitrous Oxide Fluxes. Soil Science Society of America Journal 45, 311–316. https://doi.org/10.2136/sssaj1981.03615995004500020017x
Zhao, P., Hammerle, A., Zeeman, M., Wohlfahrt, G., 2018. On the calculation of daytime CO2 fluxes measured by automated closed transparent chambers. Agricultural and Forest Meteorology 263, 267–275. https://doi.org/10.1016/j.agrformet.2018.08.022
data(co2_df_short)
data(record_short)
stupeflux(
raw_conc = co2_df_short,
field_record = record_short,
f_datetime = datetime,
start_col = start,
f_conc = conc,
measurement_length = 180,
fit_type = "exp_zhao18",
temp_air_col = temp_air,
conc_unit = "ppm",
flux_unit = "mmol",
setup_volume = 24.575,
atm_pressure = 1,
plot_area = 0.0625
)
Add the following code to your website.