ThermistorCalibrationEquationHoge3: Resistance<e2><80><93>temperature calibration equation Hoge 1

Description Usage Arguments Value Author(s) Source References

View source: R/thermocouple.R

Description

ThermistorCalibrationEquationHoge3 Resistance<e2><80><93>temperature calibration equation Hoge 3

Usage

1
 ThermistorCalibrationEquationHoge3(Rt, A0, A1, A2, A3, A4)

Arguments

Rt

resistance measurement for temperature T

A0

equation coefficient A0

A1

equation coefficient A1

A2

equation coefficient A2

A3

equation coefficient A3

A4

equation coefficient A4

Value

T

temperature

Author(s)

Jose Gama

Source

Chiachung Chen, 2009 Evaluation of resistance<e2><80><93>temperature calibration equations for NTC thermistors Measurement 42, Elsevier

References

Chiachung Chen, 2009 Evaluation of resistance<e2><80><93>temperature calibration equations for NTC thermistors Measurement 42, Elsevier