ThermistorCalibrationEquationHoge3: Resistance–temperature calibration equation Hoge 1

Description Usage Arguments Value Author(s) Source References

Description

ThermistorCalibrationEquationHoge3 Resistance–temperature calibration equation Hoge 3

Usage

1
 ThermistorCalibrationEquationHoge3(Rt, A0, A1, A2, A3, A4)

Arguments

Rt

resistance measurement for temperature T

A0

equation coefficient A0

A1

equation coefficient A1

A2

equation coefficient A2

A3

equation coefficient A3

A4

equation coefficient A4

Value

T

temperature

Author(s)

Jose Gama

Source

Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier

References

Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier



Search within the thermocouple package
Search all R packages, documentation and source code

Questions? Problems? Suggestions? or email at ian@mutexlabs.com.

Please suggest features or report bugs with the GitHub issue tracker.

All documentation is copyright its authors; we didn't write any of that.