wtConfigurePumpwell: Pumped well parameter values

wtConfigurePumpwellR Documentation

Pumped well parameter values

Description

Define WTAQ parameters related to the pumped well

Usage

wtConfigurePumpwell(ipws = 0, ipwd = 1, rw = 1, rc = ifelse(ipwd == 


    0, 0, rw), zpd = 5, zpl = 10, sw = 0, qq = 0.05, tspw = data.frame(t = 60 * 


    1:3, dd = 2 * c(0.4, 0.6, 0.7)), pwname = "PW", ipump = 1, 


    irun = 1)

Arguments

ipws

Type of pumped well:

IPWS = 0: Partially penetrating pumped well.

IPWS = 1: Fully penetrating pumped well. Default: 0

ipwd

Type of diameter of pumped well:

IPWD = 0: Infinitesimal diameter (line-source theory).

IPWD = 1: Finite diameter. Default: 1

rw

Radius of pumped well screen, in units of length. Default: 1.0

rc

Inside radius of pumped well in the interval where water levels are

changing during pumping, in units of length. Must be 0 if IPWD = 0.

Default: value of rw, but 0 if ipwd = 0.

zpd

Depth below top of aquifer or initial water table to the top of the

screened interval of the pumped well, in units of length. Default: 5.0

zpl

Depth below top of aquifer or initial water table to the bottom of the

screened interval of the pumped well, in units of length. Default: 10.0

sw

Well-bore skin parameter, dimensionless. Default: 0.0

qq

Pumping rate of well, in units of cubic length per time. Default: 0.05

tspw

data.frame with column t containing the user-specified times for

which drawdown at the pumped well will be calculated. If the data.frame

has no rows, no drawdowns are calculated for the pumped well. The

data.frame can (optionally) contain the drawdowns that have been measured

for the pumped well at the corresponding times in an additional column

dd.

pwname

Name of pumping well. This parameter is not evaluated by WTAQ but will be

used in the result data frame returned by

wtRunConfiguration. We introduce it in order to be able to

identify the well within a wellfield. Default: "PW"

ipump

Option to suppress calculations of drawdown at pumped well:

IPUMP = 0: Drawdown is not calculated at pumped well.

IPUMP = 1: Drawdown is calculated at pumped well.

irun

Option to suppress drawdown calculations for the pumped well. Allows user

to specify time-drawdown data, but those data are ignored during the

simulation. Options are:

IRUN = 0: Drawdowns not calculated.

IRUN = 1: Drawdowns calculated.

Value

list with elements irun, ipws, ipwd, ipump,

qq, rw, rc, zpd, zpl, sw,

tspw, representing WTAQ parameters related to the pumped well. See

descriptions in Arguments section.

Author(s)

Hauke Sonnenberg

See Also

wtConfigure


KWB-R/kwb.wtaq documentation built on June 17, 2022, 3:05 a.m.