get_pot: Extract independent POT values for one station

Description Usage Arguments Value Examples

Description

Use independence criterion based on Lang et al (1999)

The following calculation steps are used:

1: Find the threshold T based on the pecentile P from the observed daily data

2: Find all values abouve the thershold and identify in which direction the threshold is crossed

3: Find maximums of all clusters above thershold. A cluster is all values between an upward and a downward crossing.

4: Find the number of days between each maximum from 3

5: If data are separated by less than TTR*3, select the maximum. TTR is 'time to rize'. See Lang et al (1999)

6: Find the minimum flow between two flood events

7: if the minimum flow is higher than 2/3 of the first flood, then select the two

10.06.2016, LESC (lena schlichting)

Usage

1
2
3
get_pot(snumb = 200011, f_years = NA,
  path_dd = "inst/Example_data/Dailydata", p_threshold = 0.98, TSEP = 6,
  pratio = 2/3)

Arguments

snumb

Station number accordin to NVE: rrmmmmm where r is reine number and m is main number

f_years

Vectors of years that should be used. If NA, all years in the data file will be used

path_dd

Folder with daily data

p_threshold

The thershold for selecting flood values given as a precentile

pratio

The minimum flow between two flood peaks should be less than pratio times the first flood peak.

TTR_3X

The minimum time between two independent flood peaks

Value

data frame with reginenumber, main number, flood date, flod size, thershold for the station specified by snumb.

Examples

1
2
3
4
extract_pot_allstations(amsfile='inst/Example_data/Flooddata/amsvalues.txt',
dailydata="inst/Example_data/Dailydata",
p_threshold = 0.98, TTR_3x = 6,pratio= 2.0/3.0,
outfile="inst/Example_data/Flooddata/potvalues.txt")