LC-MS/MS data processing and spectral matching workflow

Overview

The msPurity package can be used with XCMS as part of a data processing and annotation workflow for LC-MS/MS data

XCMS (versions < 3) processing workflow

We first need to run XCMS so that we can later link the spectral matching result back to XCMS feature.

(Please use the appropriate settings for your data)

library(msPurity)
library(xcms)
mzMLpths <- list.files(system.file("extdata", "lcms", "mzML", package="msPurityData"), full.names = TRUE)

#read in the data
xset = xcms::xcmsSet(mzMLpths, method = 'centWave', mslevel=1, snthresh = 3, noise = 100, ppm = 10, peakwidth = c(3, 30))

#for this example we will subset the data to focus on retention time range 30-90 seconds and scan range 100-200 m/z
xset@peaks = xset@peaks[xset@peaks[,4] >= 30 & xset@peaks[,4] <= 90,] #retention time filter
xset@peaks = xset@peaks[xset@peaks[,1] >= 100 & xset@peaks[,1] <= 200,] #m/z filter

#group features across samples
xset = xcms::group(xset, minfrac = 0, bw = 5, mzwid = 0.017)
xcmsObj = xset

XCMS (versions 3+) processing workflow

We first need to run XCMS so that we can later link the spectral matching result back to XCMS feature.

(Please use the appropriate settings for your data)

library(msPurity)
library(magrittr)
library(xcms)
library(MSnbase)
mzMLpths <- list.files(system.file("extdata", "lcms", "mzML", package="msPurityData"), full.names = TRUE)

#read in data and subset to use data between 30 and 90 seconds and 100 and 200 m/z
msdata = readMSData(mzMLpths, mode = 'onDisk', msLevel. = 1)
rtr = c(30, 90)
mzr = c(100, 200)
msdata = msdata %>%  MSnbase::filterRt(rt = rtr) %>%  MSnbase::filterMz(mz = mzr)

#perform feature detection in individual files
cwp <- CentWaveParam(snthresh = 3, noise = 100, ppm = 10, peakwidth = c(3, 30))
xcmsObj <- xcms::findChromPeaks(msdata, param = cwp)
#update metadata
xcmsObj@phenoData@data$class = c('blank', 'blank', 'sample', 'sample')
xcmsObj@phenoData@varMetadata = data.frame('labelDescription' = c('sampleNames', 'class'))
#group chromatographic peaks across samples (correspondence analysis)
pdp <- PeakDensityParam(sampleGroups = xcmsObj@phenoData@data$class, minFraction = 0, bw = 5, binSize = 0.017)
xcmsObj <- groupChromPeaks(xcmsObj, param = pdp)

Purity assesments and linking fragmentation to XCMS features

The purityA function is then called to calculate the precursor purity of the fragmentation results and the frag4feature function will link the fragmentation data back to the XCMS feature.

pa  <- purityA(mzMLpths)
pa <- frag4feature(pa = pa, xcmsObj = xcmsObj)

Filtering and averaging

The fragmentation can be filtered prior to averaging using the “filterFragSpectra” function

pa <- filterFragSpectra(pa = pa)

Averaging of the fragmentation spectra can be done with either “averageAllFragSpectra” or with “averageIntraFragSpectra” and averageInterFragSpectra”. This will depend if the user wishes to treat the fragmentation spectra from within a file and between files. Another alternative is to ignore the averaging completely and just use the non-averaged fragmentation spectra for the spectral matching.

If the inter and intra fragmentation scans are to be treated differently the following should be followed:

pa <- averageIntraFragSpectra(pa = pa) # use parameters specific to intra spectra 
pa <- averageInterFragSpectra(pa = pa) # use parameters specific to inter spectra

If the inter and intra fragmentation scans are to be treated the same the following workflow should be used.

pa <- averageAllFragSpectra(pa = pa) 

Creating a spectral-database

An SQLite database is then created of the LC-MS/MS experiment. The SQLite schema of the spectral database can be detailed here.

td <- tempdir()
q_dbPth <- createDatabase(pa = pa, xcmsObj = xcmsObj, outDir = td, dbName = 'lcmsms-processing.sqlite')

Spectral matching

The spectralMatching function allows users to perform spectral matching to be performed for Query SQLite spectral-database against a Library SQLite spectral-database.

The query spectral-database in most cases should contain be the "unknown" spectra database generated the msPurity function createDatabase as part of a msPurity-XCMS data processing workflow.

The library spectral-database in most cases should contain the "known" spectra from either public or user generated resources. The library SQLite database by default contains data from MoNA including Massbank, HMDB, LipidBlast and GNPS. A larger database can be downloaded from here. To create a user generated library SQLite database the following tool can be used to generate a SQLite database from a collection of MSP files: msp2db. It should be noted though, that as long as the schema of the spectral-database is as described here, then any database can be used for either the library or query - even allowing for the same database to be used.

The spectral matching functionality has four main components, spectral filtering, spectral alignment, spectral matching and finally summarising the results.

Spectral filtering is simply filtering both the library and query spectra to be search against (e.g. choosing the library source, instrument, retention time, precursor PPM tolerance, xcms features etc).

The spectral alignment stage involves aligning the query peaks to the library peaks. The approach used is similar to modified pMatch algorithm described in [@Zhou2014].

The spectral matching of the aligned spectra is performed against a combined intensity and m/z weighted vector - created for both the query and library spectra (wq and wl). See below:

$$ \vec{w}=\vec{intensity}^x \cdot \vec{mz}^y$$

Where x and y represent weight factors, defaults to $x=0.5$ and $y=2$ as per MassBank recommendations for ESI based data [@Horai2008]. These can be adjusted by the user though.

The aligned weighted vectors are then matched using dot product cosine, reverse dot product cosine and the composite dot product. See below for dot product cosine equation.

$$ F_{dpc} = \frac{\sum \vec{w_{Q} }\cdot \vec{w_{L}}}{\sqrt{\sum \vec{w_{Q}^{2}}} \cdot \sqrt{\sum \vec{w_{L}^{2}}}} $$

The reverse dot product cosine (rpdc) uses the same algorithm as dpc but all peaks that do not match in the query spectra (based on the alignment) are omitted from the calculation. This will improve scores when the query spectra is noisy but should be used with caution as it might lead to more false positives.

The composite dot product cosine (cdpc) approach is also calculated - this approach is used in the NIST MS search tool and incorporates relative intensity of neighbouring peaks (see function $F_{rel}$ ), where $N$=number of peaks, $Q$=query, $L$=library, $L\&Q$= matching library and query peaks, $w$ is the weighted value and $n$ is either 1 (if the abundance ratio of the library, i.e. $\frac{w_{L,i}}{w_{L,i-1}}$, is $<$ than the abundance ratio of the query i.e. $\frac{w_{Q,i}}{w_{Q,i-1}}$) or -1 (if the abundance ratio of the library is $>$ than the abundance ratio of the query). The approach was first described in [@stein1994optimization].

$$ F_{rel} = \Bigg( \frac{1}{N_{L\&Q}-1} \Bigg) \cdot \sum_{i=2}^{N_{L\&Q}} \Bigg( \frac{w_{L,i}}{w_{L,i-1}} \Bigg){}{^n} \cdot \Bigg( \frac{w{Q,i}}{w_{Q,i-1}} \Bigg)_{}{^{-n}}$$

$$ F_{cpdc} = \frac{1000}{N_{Q} + N_{L\&Q}} \cdot (N_{Q} \cdot F_{dpc} + N_{L\&Q} \cdot F_{rel}) $$

The following example shows how to match one xcms group against library spectra filtered by their MoNA/MassBank accession id.

result <- spectralMatching(q_dbPth, q_xcmsGroups = c(432), l_accessions=c('CCMSLIB00003740033'))
print(result)

The output of spectralMatching returns a list containing the following elements:

q_dbPth: Path of the query database (this will have been updated with the annotation results if updateDb argument used)

xcmsMatchedResults If the qeury spectra had XCMS based chromotographic peaks tables (e.g c_peak_groups, c_peaks) in the sqlite database - it will be possible to summarise the matches for each XCMS grouped feature. The dataframe contains the following columns

matchedResults

All matched results from the query spectra to the library spectra. Contains the same columns as above but without the XCMS details. This table is useful to observe spectral matching results for all MS/MS spectra irrespective of if they are linked to XCMS MS1 features.

It should be noted that in a typical Data Dependent Acquisition (DDA) experiment not all the fragmentation scans collected can be linked backed to an associated XCMS features and in some cases the percentage of XCMS features with fragmentation spectra can sometimes be quite small.

References



computational-metabolomics/msPurity documentation built on Sept. 8, 2023, 8:04 p.m.