knitr::opts_chunk$set( collapse = TRUE, comment = "#>", fig.path = "adhoc/README-figures/", out.width = "100%", fig.width = 8, fig.height = 3.3, eval = FALSE )
The goal of ravetools
is to provide memory-efficient signal & image processing toolbox for intracranial Electroencephalography
. Highlighted features include:
Notch filter
(remove electrical line frequencies)Welch Periodogram
(averaged power over frequencies)Wavelet
(frequency-time decomposition)FFT
CT/MRI
to MRI
image alignmentThe package is available on CRAN
. To install the compiled version, simply run:
install.packages("ravetools")
Installing the package from source requires installation of proper compilers and some C
libraries; see this document for details.
iEEG
preprocess pipelineThis is a basic example which shows you how to preprocess an iEEG
signal. The goal here is to:
* Channel referencing is not included
library(ravetools) # Generate 20 second data at 2000 Hz time <- seq(0, 20, by = 1 / 2000) signal <- sin( 120 * pi * time) + sin(time * 20*pi) + exp(-time^2) * cos(time * 10*pi) + rnorm(length(time)) diagnose_channel(signal, srate = 2000)
Notch
filters and inspect Periodograms
## ------- Notch filter -------- signal2 <- notch_filter(signal, sample_rate = 2000) diagnose_channel(signal, signal2, srate = 2000, name = c("Raw", "Filtered"))
Current version of ravetools
provides two approaches: Wavelet
and Multi-taper
. Wavelet
uses the Morlet wavelet
and obtains both amplitude and phase data, while Multi-taper
does not generate phase data. However, the amplitude obtained from Multi-taper
is smoother than Wavelet
.
Wavelet
:## ---------- Wavelet ----------- coef <- morlet_wavelet( signal2, freqs = seq(1, 100, by = 1), srate = 2000, wave_num = c(2, 15)) amplitude <- 20 * log10(Mod(coef[])) # For each frequency, decimate to 100 Hz downsample_amp <- apply(amplitude, 2, decimate, q = 20) downsample_time <- decimate(time, q = 20) par(mfrow = c(1,1)) image( z = downsample_amp, x = downsample_time, y = seq(1, 100, by = 1), xlab = "Time (s)", ylab = "Frequency (Hz)", main = "Amplitude (dB)", sub = "Wavelet at 2000 Hz, then down-sampled to 100 Hz", col = matlab_palette() )
Multi-taper
Alternatively you can use Multi-tapers
to obtain amplitude data. The algorithm is modified from source code here. Please credit them as well if you adopt this approach.
## ---------- Multitaper ----------- res <- multitaper( data = signal2, fs = 2000, frequency_range = c(1, 100), time_bandwidth = 1.5, window_params = c(2, 0.01), nfft = 100 ) par(mfrow = c(1,1)) image( x = res$time, y = res$frequency, z = 10 * log10(res$spec), xlab = "Time (s)", ylab = 'Frequency (Hz)', col = matlab_palette(), main = "Amplitude (dB)" )
ravetools
provides imaging co-registration via NiftyReg
(doi.org/10.1117/1.JMI.1.2.024003
). You can align CT
to MRI
, or MRI
(T2) to MRI
(T1). The method can be body rigid
, affine
, or non-linear
.
source <- system.file("extdata", "epi_t2.nii.gz", package="RNiftyReg") target <- system.file("extdata", "flash_t1.nii.gz", package="RNiftyReg") aligned <- register_volume(source, target, verbose = FALSE) source_img <- aligned$source[[1]] target_img <- aligned$target aligned_img <- aligned$image par(mfrow = c(2, 2), mar = c(0.1, 0.1, 3.1, 0.1)) pal <- grDevices::grey.colors(256, alpha = 1) image(source_img[,,30], asp = 1, axes = FALSE, col = pal, main = "Source image") image(target_img[,,64], asp = 1, axes = FALSE, col = pal, main = "Target image") image(aligned_img[,,64], asp = 1, axes = FALSE, col = pal, main = "Aligned image") # bucket fill and calculate differences aligned_img[is.nan(aligned_img) | aligned_img <= 1] <- 1 target_img[is.nan(target_img) | aligned_img <= 1] <- 1 diff <- abs(aligned_img / target_img - 1) image(diff[,,64], asp = 1, axes = FALSE, col = pal, main = "Percentage Difference")
RAVE
paper from Beauchamp's lab
Magnotti, JF, and Wang, Z, and Beauchamp, MS. RAVE: comprehensive open-source software for reproducible analysis and visualization of intracranial EEG data. NeuroImage, 223, p.117341.
The multitaper
function (MIT License) uses the script derived from Prerau's lab
. The TinyParallel
script is derived from RcppParallel
package (GPL License) with TBB
features removed (only use tinythreads
). The register_volume
function uses NiftyReg
(BSD License) developed by CMIC
at University College London, UK (its R implementation is released under GPL license).
[1] Magnotti, JF, and Wang, Z, and Beauchamp, MS. RAVE: comprehensive open-source software for reproducible analysis and visualization of intracranial EEG data. NeuroImage, 223, p.117341. [2] Prerau, Michael J, and Brown, Ritchie E, and Bianchi, Matt T, and Ellenbogen, Jeffrey M, and Purdon, Patrick L. Sleep Neurophysiological Dynamics Through the Lens of Multitaper Spectral Analysis. Physiology, December 7, 2016, 60-92. [3] Modat, M., Cash, D.M., Daga, P., Winston, G.P., Duncan, J.S. and Ourselin, S., 2014. Global image registration using a symmetric block-matching approach. Journal of medical imaging, 1(2), pp.024003-024003. [4] JJ Allaire, Romain Francois, Kevin Ushey, Gregory Vandenbrouck, Marcus Geelnard and Intel (2022). RcppParallel: Parallel Programming Tools for 'Rcpp'. R package version 5.1.5. https://CRAN.R-project.org/package=RcppParallel
Add the following code to your website.