Description Usage Arguments Value Author(s) References See Also Examples
View source: R/cooper_utilities.R
Function to calculate the hydraulic parameters of a cooper solution for a slug test
1 | cooper_calculate_parameters(ptest, par, hydraulic = TRUE)
|
ptest |
A pumping_test object |
par |
A list with the dimensionless wellbore storage coefficient (cd) and the Intercept of the straight line fitted to the drawdown data using the Cooper-Jacob approach (t0) |
hydraulic |
Logical flag to indicate if hydraulic parameters are calculated. If False, the the statistcal parameter are calculated. |
A list with
Tr: Transmisivity
Ss: Storage coefficient
radius_influence: radius of influence
Oscar Garcia-Cabrejo khaors@gmail.com
Cooper, H. H.; Bredehoeft, J. D. & Papadopulos, I. S. Response of a finite-diameter well to an instantaneous charge of water Water Resources Research, 1967, 3, 263-269
Other cooper functions: cooper_WF_LT
,
cooper_solution_dlogt
,
cooper_solution_initial
,
cooper_solution
,
cooper_well_function
1 2 3 4 5 6 7 | data(cooper_slug)
ptest <- pumping_test("Well1", Q = 0, r = 0, t = cooper_slug$t, s = cooper_slug$s)
par <- list(rw = 0.071, rc = 0.025)
ptest$additional_parameters <- par
sol0 <- cooper_solution_initial(ptest)
hydr.par <- cooper_calculate_parameters(ptest,sol0)
print(hydr.par)
|
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.