atm_pressure | Barometric formula (Atm. Pressure) |
cavtation_index | Cavitation Index (Regime) |
cavtation_regime | Cavitation Level (Regime) |
cylinder_param | calculation of the cylinder parameter |
darcy_weisbach | Darcy–Weisbach equation |
dp_max | Differential pressure maximum between upstream and downstream... |
drm_LL3 | dose-response models. |
dynamic_viscosity | Water Dynamic Viscosity |
ff | Ff Liquid critical pressure ratio factor |
fl_function | Function FL liquid pressure recovery factor |
flow_calculation | Flow Calculation |
flow_Kv | flow in function of the flow coefficient Kv |
flp | Flp Combined liquid pressure recovery factor |
fp | Fp Piping geometry factor |
fr | Title |
friction_colebrook | Colebrook–White equation (Darcy friction factor formula) |
inv_LL3 | Inverse of the dose-response models. |
kinematic_viscosity | Kinematic Viscosity |
kv | Valve flow coefficient |
kv_value | Flow coefficient Kv Value in function of the Zeta Value |
minor_losses | Minor Losses |
plot_fl | Plot liquid pressure recovery factor |
plot_kv | Plot Flow coefficient Kv Value |
plot_kv_kvs | Plot the Valve flow coefficient |
plotly_kv | Plotly Flow Coefficient (Kv) of the valve |
plotly_kv_kvs | Plotly the Valve flow coefficient |
plotly_sigma | Plotly Cavitation Coefficients |
plotly_zv | Plotly Zeta Value Curve |
plot_sigma | Plot sigma for Incipient, Constant and Maximum cavitation |
plot_zv | Plot Zeta Value Curve |
points_cloud_param | Calculation of the factors for the points cloud |
q_max | the maximum flow through the valve |
resistance_coefficient | Resistance coefficients of all fittings attached to the... |
reynolds_factor | Reynolds number factor for valve sizing. |
reynolds_number | Reynolds number |
Reynolds_valve | Valve Reynolds number |
segment_data | Return segment data |
sigma_0 | cavitation index (Reference upstream pressure P1): |
sigma_1 | cavitation index (Reference downstream pressure P2): |
sigma_2 | cavitation index (Reference downstream pressure P2): |
Sigma_c | Constant Cavitation. |
Sigma_i | Incipient Cavitation. |
Sigma_mv | Maximum Vibration Cavitation |
tab_param_points | Parameters of the Points at the valve |
valve_analyze | Valve Analyze |
valve_param_calc | data_analyze selection of the right valve type |
vapour_pressure | Vapour pressure of water |
velocity | Velocity in a pipe |
water_density | Saturated water Density |
zeta_vaule | Resistance Coefficient Zeta in function of Kv |
zv_function | Function Resistance Coefficient Zeta |
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.