Description Usage Arguments Value Author(s) Examples
View source: R/valve_hydrailic_functions.R
Pressure drop or head loss is proportional to the velocity in valves or fittings. For the most engineering practices it can be assumed that pressure drop or head loss due to flow of fluids in turbulent range through valves and fittings is proportional to square of velocity.
1 | zeta_vaule(dn, kv)
|
dn |
diameter in millimeter (mm) |
kv |
Kv Flow coefficient in m³/h |
Zeta Vaule
Dr. Raúl Trujillo Álvarez
1 | zeta_vaule( dn = 500, kv = 7247.229)
|
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.