Sigma_i: Incipient Cavitation.

Description Usage Arguments Value

View source: R/valve_hydrailic_functions.R

Description

The onset of cavitation, where only small vapor bubbles are formed in the flow stream. A cavitation level sufficient to begin minor, observable indications of pitting damage. - Onset of cavitation; - Detect using high-frequency vibration measurement; - Very local phenomenon; Transient: random “ticks” sound; - Low-level cavitation: usually not damaging; - Occurs prior to the loss of capacity

Usage

1
Sigma_i(x, b, d, e, fls)

Arguments

x

valve position

b

steepness

d

upper value

e

the effective dose

fls

liquid pressure recovery full open (max between fl and Flp/Fp)

Value

Sigma_i