The onset of cavitation, where only small vapor bubbles are formed in the flow stream. A cavitation level sufficient to begin minor, observable indications of pitting damage. - Onset of cavitation; - Detect using high-frequency vibration measurement; - Very local phenomenon; Transient: random “ticks” sound; - Low-level cavitation: usually not damaging; - Occurs prior to the loss of capacity
1 | Sigma_i(x, b, d, e, fls)
|
x |
valve position |
b |
steepness |
d |
upper value |
e |
the effective dose |
fls |
liquid pressure recovery full open (max between fl and Flp/Fp) |