knitr::opts_chunk$set(echo = TRUE)
antaresFlowbased
allows to model flow-based domains into adequacy studies using the software Antares, with the following main functionalities:
1. Preparation of the input of an Antares study to include a modelling a flow-based in the CWE area
2. Post-processing and visualisation of Antares’ results
This vignette describes the second set of functionnalities : the post-processing of the simulation results.
# Set Antares study path and read the simulation results study <- "MyStuDy" opts <- antaresRead::setSimulationPath(study, 2) dta <- antaresRead::readAntares(areas = c("fr", "be", "de", "nl"), links = c("be - de","be - fr","be - nl", "de - fr","de - nl"), mcYears = 1:10, select = c("LOLD", "UNSP. ENRG", "DTG MRG", "UNSP. ENRG", "BALANCE", "FLOW LIN."), opts = opts) # Add to the results the time series of typical flow-based days dta <- addTypicalDayId(dta) # Apply the adequacy patch on the results dta_adq <- adqPatch(mcYears = "all", pre_filter = FALSE, strategic_reserve_be = NULL, strategic_reserve_de = NULL, opts = antaresRead::simOptions(), fb_opts = opts, select = NULL, keepOldColumns = TRUE) # Visualise the flow-based exchanges (position in the flow-based domains) before or after the adequacy patch # Plot a domain and the matching output positions plotNetPositionFB(fb_opts = opts, data = dta_adq, drawPositionsAdqP = FALSE, dayType = 1, hour = c(0, 19), country1 = "BE", country2 = "FR") # Run a shiny application to visualise the domains and matching output positions runAppPosition(dta_adq) # Add to the results a calculation of the net position of the countries within an area (by default, position in CWE) dta <- addNetPosition(data, opts = antaresRead::simOptions(), inAreas = c("be", "de", "fr", "nl"), adq = FALSE, newName = "_CWE") # h5 file: apply the adequacy patch to an output in h5 format adqH5(opts, fb_opts = setFlowbasedPath(path = "D:/model1"))
antaresRead::setSimulationPath("MyStuDy", 1) dta <- readAntares(areas = "all", links = "all", clusters = "all" ,mcYears = 1:10) dta <- addTypicalDayId(data = dta)
The function addTypicalDayId()
adds to an Antares output table a column indicating the id of the used flow-based typical days at each timestep. It uses the following parameters :
data
: Antares output table (loaded by the function antaresRead::readAntares
), the function will add a column to this tablefb_opts
: flow-based model localisation, where the function will read the flow-based time-series to add to the results. It can be a flow-based model designed by setFlowbasedPath()
. By default, it will use the odel stored in the Antares study indicated by antaresRead::simOptions()
Although it is applied as a post-processing for Antares, the adequacy patch is in reality an integral part of the market coupling algorithm.
This patch intervenes in case of unsupplied energy : the optimal situation will be the one reducing the maximum amount of unsupplied energy in the whole interconnected areas and this may lead to increasing the unsupplied energy in some areas (countries exporting while in loss of load situation for example). The aim of the patch is to move from the optimal situation at CWE perimeter to a solution splitting the effort in a « fair » way.
This function is a post-processing of Antares results (optimisation algorithm), its aim is to re-compute the net positions (exports - imports) in the CWE area while :
Example : Area "fr" is exporting while having unsupplied energy. After the post-processing, it is exporting only the volume it can to reduce area "be" 's unsupplied energy without endangering its own safety.
opts <- antaresRead::setSimulationPath("MyStuDy", 2) dta <- adqPatch(mcYears = "all", pre_filter = FALSE, strategic_reserve_be = NULL, strategic_reserve_de = NULL, opts = antaresRead::simOptions(), fb_opts = opts, select = NULL, keepOldColumns = TRUE) ## or dta <- adqPatch(fb_opts = opts)
The adqPatch()
function applies a post-processing on an Antares study output. It loads the results of the study indicated by antaresRead::setSimulationPath()
and selects the times with unsupplied energy to apply the patch optimisation algorithm described above.
By default, the function returns the results for all the MC years :
It uses the following parameters :
mcYears
: selection of MC years to apply the patch on. By default, the value is "all".pre_filter
: boolean, if TRUE, the function selects (by reading annual results) the mcYears during which there is at least one hour of loss of load before applying the adequacy patch, the other years are not loaded and will not appear in the results of the function. By default, the value is FALSE.strategic_reserve_be
: name of the area representing the strategic reserve of be, by default NULL.strategic_reserve_de
: name of the area representing the strategic reserve of de, by default NULL.select
: names of additionnal output colums to have in the results (other than the ones quoted above). These columns are directly loaded from Antares, unchanged.opts
: Antares study, indicated by the function antaresRead::setSimulationPath()
fb_opts
: simulation parameters returned by the function setSimulationPath()
or flow-based model path obtained with the function setFlowbasedPath()
. By default, the value is indicated by antaresRead::simOptions()
keepOldColumns
: boolean, if TRUE, the initial columns modified by the adequacy patch are also displayed after the post-processing. By default, the value is TRUE.Preliminary step: load the simulation results.
opts <- antaresRead::setSimulationPath("MyStuDy", 2) dta <- antaresRead::readAntares(areas = c("fr", "be", "de", "nl"), links = c("be - de","be - fr","be - nl","de - fr","de - nl"), mcYears = 1:10, select = c("LOLD", "UNSP. ENRG", "DTG MRG", "UNSP. ENRG", "BALANCE", "FLOW LIN."))
The function plotNetPositionFB()
is used after running an Antares simulation to visualize how the domains have been used by the optimizer to fix the exchanges in the CWE area.
The parameters used by the function are the following (example on how to use them are described below):
data
: antaresDataList
Antares output data, imported with readAntares()
. It can be a filtered (time or loss of load) antaresDataList.dayType
: numeric vector of typical days' domains to plot or "all"hour
: numeric vector of hours to plot (between 0 and 23) or "all"country1
: name of the country in axis Xcountry2
: name of the country in axis Yfb_opts
: flow-based model, either defined by setFlowbasedPath()
or in the study indicated by setSimulationPath()
. By default : antaresRead::simOptions()
filteringEmptyDomains
: boolean, if TRUE, the function will not plot the domains which are not used in the data. By default, it is FALSE.nbMaxPt
: maximum number of points plotted on the graph. It can be increased (which increases computation time). By default, the value is 10000.drawPositionsBeforeAdqP
: boolean, draw the net positions without adequacy patch being applied (or before). If TRUE, the data without adequacy patch must be included in data. By default the value is TRUE.drawPositionsAdqP
: boolean, draw the Net Positions after the adequacy patch is applied. If TRUE, the data resulting of the adequacy patch process must be included in data. By default, the value is TRUE.palette
: color range, by default rainbow.The user chooses the typical day(s) and hour(s), the function will plot the required domain(s) and search the Antares results to calculate the net positions whenever these domains were used by the optimiser.
## Plot the typical day 1 at hours 0 and 19 and the matching net positions on a Belgium-France graph plotNetPositionFB(fb_opts = opts, data = dta, dayType = 1, hour = c(0, 19), country1 = "BE", country2 = "FR")
## Plot the three typical days of summer at hour 19 and the matching net positions plotNetPositionFB(fb_opts = opts, data = dta, dayType = c(1,2,3), hour = c(19), country1 = "BE", country2 = "FR")
By default, the function draws all the times matching the domains in the entire results table. It is then possible to filter the input table. If so, the parameter filteringEmptyDomains
can be set to TRUE and the parameters dayType
and hour
to ALL. The function will then try and print all the domains, but actually keep only the ones used in the table.
## Plot only one time, without knowing the used flow-based domain dta$areas <- dta$areas[timeId == 5659,] plotNetPositionFB(fb_opts = opts, data = dta, dayType = "all", hour = "all", filteringEmptyDomains = TRUE, country1 = "FR", country2 = "DE")
Because of the format of the Antares data table, some caution must be observed when filtering it. For example, to keep only the situations where there is unsupplied energy, one must keep all the rows representing this specific time. Example :
## An exemple of authorized filter : idC <- c(antaresRead::getIdCols(dta$areas)) idC <- idC[idC!="area"] LOLD <- dta$areas[,lapply(.SD, sum), by = idC, .SDcols = "LOLD"] LOLD <- LOLD[LOLD!=0] LOLD[,LOLD := NULL] # Merge to filter data dta$areas <- merge(dta$areas, LOLD, by = idC) ## End filter ## plot domains plotNetPositionFB(fb_opts = opts, data = dta, dayType = "all", hour = c(19), country1 = "BE", country2 = "FR", filteringEmptyDomains = TRUE)
Provided that the data are in the table given in input of the function, it is possible to plot the net positions before or after adequacy patch or even the two at the same time. To do so, the parameters drawPositionsBeforeAdqP and/or drawPositionsAdqP must be set to TRUE (default value).
## Apply the adequacy patch opts <- antaresRead::setSimulationPath("MyStuDy", 2) data_withAdq <- adqPatch(keepOldColumns = TRUE) ## Plot the hours 0 and 19 of typical day 1 plotNetPositionFB(fb_opts = opts, data = data_withAdq, dayType = 1, hour = c(0, 19), country1 = "BE", country2 = "FR", drawPositionsBeforeAdqP = TRUE, drawPositionsAdqP = TRUE)
It is also possible to apply the filter presented above to keep only situations in which the adequacy patch has really been applied (with unsupplied energy in the area)
## Filter on LOLD : idC <- c(antaresRead::getIdCols(data_withAdq$areas)) idC <- idC[idC!="area"] LOLD <- data_withAdq$areas[,lapply(.SD, sum), by = idC, .SDcols = "LOLD"] LOLD <- LOLD[LOLD!=0] LOLD[,LOLD := NULL] data_withAdq$areas <- merge(data_withAdq$areas, LOLD, by = idC) ## plot plotNetPositionFB(fb_opts = opts, data = data_withAdq, dayType = c(5,6,7), hour = c(19), country1 = "BE", country2 = "FR", drawPositionsBeforeAdqP = TRUE, drawPositionsAdqP = TRUE)
One can also visualise the net positions graphs in a shiny application launched with runAppPosition
. Two parameters only are used (data
and fb_opts
), the others are available directly in the app.
runAppPosition(dta)
The same filters can also be applied beforehand to select only timesteps with unsupplied energy.
opts <- antaresRead::setSimulationPath("MyStuDy", 2) data <- readAntares(area = "all", links = "all", mcYears = 1) ##Add net position for CWE data <- addNetPosition(data, opts, adq = FALSE) ##Add net position for CWE+AT data <- addNetPosition(data, opts, adq = FALSE, inAreas = c("be", "de", "fr", "nl", "at"), newName = "_CWEAt")
The function addNetPosition()
adds to an Antares output table a column calculating the net position of areas within an interconnected group of areas, based on the exchanged flows. This can be used for flow-based calculation (to get net positions in the CWE perimeter). It uses the following parameters :
data
: Antares output table (loaded by the function antaresRead::readAntares()
), the function will add a column to this tableopts
: simulation parameters returned by the function setSimulationPath()
: this represents the directory of the Antares study. The default path is indicated by antaresRead::simOptions()
.inAreas
: lists of areas belonging to the perimeter, whose exchanges are going to be taken into account in the balance calculation. All links connecting two areas in this list are taken into account, the links connected to only one area (or none) are ignored. By default, the list is c("be", "de", "fr", "nl"), the calculation is carried out on the CWE perimeter.adq
: boolean, calculates the net positions of the areas based on post-adequacy patch results. By default, the value is FALSE.newName
: suffix added to the calculated column name. By default, it is "_CWE".The funtion adqH5()
enables to apply the adequacy patch on a simulation in h5 format and returns the results in the same format. The plot functions and application can be used on an h5 file.
## Select the Antares simulation # Select the output in a classic format opts <- antaresRead::setSimulationPath("MyStuDy",2) # Write the study in h5 format antaresRead::writeAntaresH5() # Select the simulation now in an h5 file opts <- antaresRead::setSimulationPath("MyNewStudy",1) ## Select the flow-based model to use. The function setFlowbasedPath can also be used fb_opts = antaresRead::setSimulationPath("MyOldStudy", 2) ## Apply the adequacy patch adqH5(opts = opts, fb_opts = fb_opts, strategic_reserve_be = NULL, strategic_reserve_de = NULL) ## Set alias for an easy read of the file afterwards setAlias("adqPatch", "Alias for adqPatch", c("LOLD_ADQPatch", "UNSP. ENRG_ADQPatch", "DTG MRG_ADQPatch", "UNSP. ENRG_ADQPatch", "BALANCE_ADQPatch", "FLOW LIN._ADQPatch", "areas", "links")) ## Read the results of the patch with alias readAntares(select = "adqPatch", opts = opts, mcYears = 1)
The function has only a few parameters :
opts
: the designation of the Antares simulation, it must indicate an output in h5 format. These parameters are returned by the function setSimulationPath()
. The default path is indicated by antaresRead::simOptions()
.fb_opts
: the flow-based model to use. Simulation parameters returned by the function setSimulationPath or flow-based model path obtained with the function setFlowbasedPath()
. By default, the value is indicated by antaresRead::simOptions()
strategic_reserve_be
: name of the area representing the strategic reserve of be, by default NULL.strategic_reserve_de
: name of the area representing the strategic reserve of de, by default NULL.In the h5 file, all the columns are automatically kept, including the columns of results before adequacy patch (parameter keepOldColumn in the function adqPatch()
to TRUE). It is furthermost impossible to select only a few MC years to apply the patch on, or to use the pre-filter parameter.