hunt <- function(t, d, S, Tr, lmda, lmda_max = Inf, prec = 80) {
#' Streamflow depletion in partially penetrating stream with semipervious streambed.
#'
#' @param t times you want output for [T]
#' @param d distance from well to stream [L]
#' @param S aquifer storage coefficient (specific yield if unconfined; storativity if confined)
#' @param Tr aquifer transmissivity [L2/T]
#' @param lmda streambed conductance term, lambda [L/T]. Can be estimated with \code{streambed_conductance}.
#' @param lmda_max maximum allowed `lmda` [L/T]. If `lmda` is too high, exp and erfc calculations in Hunt solution are not computationally possible, so you may need to artifically reduce `lmda` using this term.
#' @param prec precision for \code{Rmpfr} package for storing huge numbers; 80 seems to generally work but tweak this if you get weird results. Reducing this value will reduce accuracy but speed up computation time. If set to `NULL`, the `mpfr` function is not used which can address an occasional issue on Mac computers but lead to problems under some combinations of `Tr` and `lmda`.
#' @details This function is described in Hunt (1999). When \code{lmda} term gets very large, this is equivalent to \link{glover}. It contains numerous assumptions:
#' \itemize{
#' \item Horizontal flow >> vertical flow (Dupuit assumptions hold)
#' \item Homogeneous, isotropic aquifer
#' \item Constant \code{Tr}: Aquifer is confined, or if unconfined change in head is small relative to aquifer thickness
#' \item Stream is straight, infinitely long, and remains in hydraulic connection to aquifer
#' \item Constant stream stage
#' \item No changes in recharge due to pumping
#' \item No streambank storage
#' \item Constant pumping rate
#' \item Aquifer extends to infinity
#' }
#' @return A numeric of \code{Qf}, streamflow depletion as fraction of pumping rate [-].
#' If the pumping rate of the well (\code{Qw}; [L3/T]) is known, you can calculate volumetric streamflow depletion [L3/T] as \code{Qf*Qw}
#' @importFrom magrittr %>%
#' @references
#' Hunt, B (1999). Unsteady Stream Depletion from Ground Water Pumping.
#' Ground Water 37 (1): 98-102. doi:10.1111/j.1745-6584.1999.tb00962.x.
#' @examples
#' hunt(t = 1826, d = 1000, S = 0.2, Tr = 8640, lmda = 864) # ~equal to glover because lmda=Tr
#' hunt(t = 1826, d = 1000, S = 0.2, Tr = 8640, lmda = 0.864) # less depletion due to lower lmda
#'
#' lmda <- streambed_conductance(w = 10, Kriv = 0.0864, briv = 1) # estimate lmda
#' hunt(t = 1826, d = 1000, S = 0.2, Tr = 8640, lmda = lmda)
#'
#' Qf <- hunt(t = seq(1, 1826), d = 1000, S = 0.2, Tr = 8640, lmda = 0.864)
#' plot(x = seq(1, 1826), y = Qf, type = "l")
#' @export
# reduce lmda if exceeds lmda_max
lmda[lmda > lmda_max] <- lmda_max
# erfc and exp terms can get really huge; use the Rmpfr package to deal with them
if (is.null(prec)){
term1 <- Rmpfr::erfc(sqrt((S * d * d) / (4 * Tr * t)))
term2 <- exp(((lmda * lmda * t) / (4 * S * Tr) + (lmda * d) / (2 * Tr)))
term3 <- Rmpfr::erfc(sqrt((lmda * lmda * t) / (4 * S * Tr)) + sqrt((S * d * d) / (4 * Tr * t)))
} else {
term1 <- Rmpfr::erfc(Rmpfr::mpfr(sqrt((S * d * d) / (4 * Tr * t)), prec))
term2 <- exp(Rmpfr::mpfr(((lmda * lmda * t) / (4 * S * Tr) + (lmda * d) / (2 * Tr)), prec))
term3 <- Rmpfr::erfc(Rmpfr::mpfr(sqrt((lmda * lmda * t) / (4 * S * Tr)) + sqrt((S * d * d) / (4 * Tr * t)), prec))
}
# check for issues
errors <- which(!is.finite(term2))
if (length(errors) > 0) stop(paste0("Term 2 = Inf for ", length(errors), " calculation(s). Usually means lmda is too high or Tr is too low. Try using lmda_max?"))
Qf <- as.numeric(term1 - term2 * term3)
return(Qf)
}