phase1EN1995_k | R Documentation |
Compliance, uncertain compliance or non-compliance can be evaluated for at least three measurements. Calculation of exposure indeces is performed (worker measurement/OEL). Compliance is achieved if all indeces are below or equal to 0.25. If at least an index is greater than 0.25 but all indeces are lower/equal than 1 and the geometric mean of the measurements is lower/equal than 0.5, Compliance is accomplished. Contrarly, there is no decision ("UC"). There is Non-Compliance if at least a measurement is greater than the OEL and/or if at least an exposure index is greater than 1.
phase1EN1995_k(measurements, OEL)
measurements |
At least 3 measurements |
OEL |
Occupational Exposure Limit of the agent |
Compliance (C"), Non-Compliance ("NC") or Uncertainty of Compliance ("UC")