View source: R/phaseTwo_EN6891995.R
phase2EN689.1995 | R Documentation |
The normal distribution of the measurements is operated, and 99.9th percentile and 95th percentile values are observed to assess the possible exceedance of the OEL. Compliance or "Green Area" is achieved if the value of the 99,9 the percentile is lower than the OEL, Uncertain Compliance or "Orange Area" is achieved if the value of the 95th percentile is lower than the OEL. Non Compliance or "Red Area" is achieved if the OEL is greater than the value of the 95th percentile.
phase2EN689.1995(measurements, OEL)
measurements |
measurements of the SEG under assessment |
OEL |
Occupational Exposure Limit of the agent |
Green Area, Orange Area or Red Area