BiocStyle::markdown()
Package: r Biocpkg("xcms")
Authors: Johannes Rainer
Modified: r file.info("xcms.Rmd")$mtime
Compiled: r date()
## Silently loading all packages library(BiocStyle) library(xcms) library(faahKO) library(pander) ## Use socket based parallel processing on Windows systems if (.Platform$OS.type == "unix") { register(bpstart(MulticoreParam(3))) } else { register(bpstart(SnowParam(3))) }
This documents describes data import, exploration, preprocessing and analysis of
LCMS experiments with xcms
version >= 3. The examples and basic workflow was
adapted from the original LC/MS Preprocessing and Analysis with xcms vignette
from Colin A. Smith.
The new user interface and methods use the XCMSnExp
object (instead of the
old xcmsSet
object) as a container for the pre-processing results. To
support packages and pipelines relying on the xcmsSet
object, it is however
possible to convert an XCMSnExp
into a xcmsSet
object using the as
method
(i.e.xset <- as(x, "xcmsSet")
, with x
being an XCMSnExp
object.
xcms
supports analysis of LC/MS data from files in (AIA/ANDI) NetCDF,
mzML/mzXML and mzData format. For the actual data import Bioconductor's
r Biocpkg("mzR")
is used. For demonstration purpose we will analyze a
subset of the data from [@Saghatelian04] in which the metabolic consequences of
knocking out the fatty acid amide hydrolase (FAAH) gene in mice was
investigated. The raw data files (in NetCDF format) are provided with the
faahKO
data package. The data set consists of samples from the spinal cords of
6 knock-out and 6 wild-type mice. Each file contains data in centroid mode
acquired in positive ion mode form 200-600 m/z and 2500-4500 seconds.
Below we load all required packages, locate the raw CDF files within the faahKO
package and build a phenodata data frame describing the experimental setup.
library(xcms) library(faahKO) library(RColorBrewer) library(pander) library(magrittr) library(pheatmap) ## Get the full path to the CDF files cdfs <- dir(system.file("cdf", package = "faahKO"), full.names = TRUE, recursive = TRUE) ## Create a phenodata data.frame pd <- data.frame(sample_name = sub(basename(cdfs), pattern = ".CDF", replacement = "", fixed = TRUE), sample_group = c(rep("KO", 6), rep("WT", 6)), stringsAsFactors = FALSE)
Subsequently we load the raw data as an OnDiskMSnExp
object using the
readMSData
method from the r Biocpkg("MSnbase")
package. The MSnbase
provides based structures and infrastructure for the processing of mass
spectrometry data. Also, MSnbase
can be used to centroid profile-mode MS
data (see the corresponding vignette in the MSnbase
package).
raw_data <- readMSData(files = cdfs, pdata = new("NAnnotatedDataFrame", pd), mode = "onDisk")
raw_data <- filterRt(raw_data, c(2500, 4000))
The resulting OnDiskMSnExp
object contains general information about the
number of spectra, retention times, the measured total ion current etc, but does
not contain the full raw data (i.e. the m/z and intensity values from each
measured spectrum). Its memory footprint is thus rather small making it an ideal
object to represent large metabolomics experiments while allowing to perform
simple quality controls, data inspection and exploration as well as data
sub-setting operations. The m/z and intensity values are imported from the raw
data files on demand, hence the location of the raw data files should not be
changed after initial data import.
The OnDiskMSnExp
organizes the MS data by spectrum and provides the methods
intensity
, mz
and rtime
to access the raw data from the files (the measured
intensity values, the corresponding m/z and retention time values). In addition,
the spectra
method could be used to return all data encapsulated in Spectrum
objects. Below we extract the retention time values from the object.
head(rtime(raw_data))
All data is returned as one-dimensional vectors (a numeric vector for rtime
and a list
of numeric vectors for mz
and intensity
, each containing the
values from one spectrum), even if the experiment consists of multiple
files/samples. The fromFile
function returns an integer vector providing
the mapping of the values to the originating file. Below we use the fromFile
indices to organize the mz
values by file.
mzs <- mz(raw_data) ## Split the list by file mzs_by_file <- split(mzs, f = fromFile(raw_data)) length(mzs_by_file)
As a first evaluation of the data we plot below the base peak chromatogram (BPC)
for each file in our experiment. We use the chromatogram
method and set the
aggregationFun
to "max"
to return for each spectrum the maximal intensity
and hence create the BPC from the raw data. To create a total ion chromatogram
we could set aggregationFun
to sum
.
## Get the base peak chromatograms. This reads data from the files. bpis <- chromatogram(raw_data, aggregationFun = "max") ## Define colors for the two groups group_colors <- paste0(brewer.pal(3, "Set1")[1:2], "60") names(group_colors) <- c("KO", "WT") ## Plot all chromatograms. plot(bpis, col = group_colors[raw_data$sample_group])
The chromatogram
method returned a Chromatograms
object that organizes
individual Chromatogram
objects (which in fact contain the chromatographic
data) in a two-dimensional array: columns represent samples and rows
(optionally) m/z and/or retention time ranges. Below we extract the chromatogram
of the first sample and access its retention time and intensity values.
bpi_1 <- bpis[1, 1] head(rtime(bpi_1)) head(intensity(bpi_1))
The chromatogram
method supports also extraction of chromatographic data from
a m/z-rt slice of the MS data. In the next section we will use this method to
create an extracted ion chromatogram (EIC) for a selected peak.
Note that chromatogram
reads the raw data from each file to calculate the
chromatogram. The bpi
and tic
methods on the other hand do not read any data
from the raw files but use the respective information that was provided in the
header definition of the input files (which might be different from the actual
data).
Below we create boxplots representing the distribution of total ion currents per file. Such plots can be very useful to spot problematic or failing MS runs.
## Get the total ion current by file tc <- split(tic(raw_data), f = fromFile(raw_data)) boxplot(tc, col = group_colors[raw_data$sample_group], ylab = "intensity", main = "Total ion current")
Also, we can cluster the samples based on similarity of their base peak
chromatogram. This can also be helpful to spot potentially problematic samples
in an experiment or generally get an initial overview of the sample grouping in
the experiment. Since the retention times between samples are not exactly
identical, we use the bin
function to group intensities in fixed time ranges
(bins) along the retention time axis. In the present example we use a bin size
of 1 second, the default is 0.5 seconds. The clustering is performed using
complete linkage hierarchical clustering on the pairwise correlations of the
binned base peak chromatograms.
## Bin the BPC bpis_bin <- bin(bpis, binSize = 2) ## Calculate correlation on the log2 transformed base peak intensities cormat <- cor(log2(do.call(cbind, lapply(bpis_bin, intensity)))) colnames(cormat) <- rownames(cormat) <- raw_data$sample_name ## Define which phenodata columns should be highlighted in the plot ann <- data.frame(group = raw_data$sample_group) rownames(ann) <- raw_data$sample_name ## Perform the cluster analysis pheatmap(cormat, annotation = ann, annotation_color = list(group = group_colors))
The samples cluster in a pairwise manner, the KO and WT samples for the sample index having the most similar BPC. In addition, 3 larger clusters are present grouping KO and WT samples 21 and 22 together as well as 18 and 19. KO and WT samples 15 and 16 separate from these two clusters.
Next we perform the chromatographic peak detection using the centWave
algorithm [@Tautenhahn:2008fx]. Before running the peak detection it is however
strongly suggested to visually inspect e.g. the extracted ion chromatogram of
internal standards or known compounds to evaluate and adapt the peak detection
settings since the default settings will not be appropriate for most LCMS
experiments. The two most critical parameters for centWave are the peakwidth
(expected range of chromatographic peak widths) and ppm
(maximum expected
deviation of m/z values of centroids corresponding to one chromatographic peak;
this is usually much larger than the ppm specified by the manufacturer)
parameters. To evaluate the typical chromatographic peak width we plot the EIC
for one peak.
## Define the rt and m/z range of the peak area rtr <- c(2700, 2900) mzr <- c(334.9, 335.1) ## extract the chromatogram chr_raw <- chromatogram(raw_data, mz = mzr, rt = rtr) plot(chr_raw, col = group_colors[chr_raw$sample_group])
Note that Chromatogram
objects extracted by the chromatogram
method contain
an NA
value if in a certain scan (i.e. for a specific retention time) no
signal was measured in the respective mz range. This is reflected by the lines
not being drawn as continuous lines in the plot above.
The peak above has a width of about 50 seconds. The peakwidth
parameter should
be set to accommodate the expected widths of peak in the data set. We set it to
20,80
for the present example data set.
For the ppm
parameter we extract the full MS data (intensity, retention time
and m/z values) corresponding to the above peak. To this end we first filter the
raw object by retention time, then by m/z and finally plot the object with type
= "XIC"
to produce the plot below. We use the pipe (%>%
) command better
illustrate the corresponding workflow. Note also that in this type of plot
identified chromatographic peaks would be indicated by default if present.
raw_data %>% filterRt(rt = rtr) %>% filterMz(mz = mzr) %>% plot(type = "XIC")
In the present data there is actually no variation in the m/z values. Usually
one would see the m/z values (lower panel) scatter around the real m/z value
of the compound. The first step of the centWave algorithm defines so called
regions of interest (ROI) based on the difference of m/z values from consecutive
scans. In detail, m/z values from consecutive scans are included into a ROI if
the difference between the m/z and the mean m/z of the ROI is smaller than the
user defined ppm
parameter. A reasonable choice for the ppm
could thus be
the maximal m/z difference of data points from neighboring scans/spectra that
are part of the chromatographic peak. It is suggested to inspect the ranges of
m/z values for many compounds (either internal standards or compounds known to
be present in the sample) and define the ppm
parameter for centWave
according to these.
Note that we can also perform the peak detection on the extracted ion
chromatogram. This can help to evaluate different peak detection settings. Only
be aware that peak detection on an extracted ion chromatogram will not consider
the ppm
parameter and that the estimation of the background signal is
different to the peak detection on the full data set; values for the snthresh
will hence have different consequences. Below we perform the peak detection with
the findChromPeaks
function on the extracted ion chromatogram. The submitted
parameter object defines which algorithm will be used and allows to define the
settings for this algorithm. We use the centWave algorithm with default
settings, except for snthresh
.
xchr <- findChromPeaks(chr_raw, param = CentWaveParam(snthresh = 2))
We can access the identified chromatographic peaks with the chromPeaks
function.
head(chromPeaks(xchr))
Parallel to the chromPeaks
matrix there is also a data frame chromPeakData
that allows to add arbitrary annotations to each chromatographic peak. Below we
extract this data frame that by default contains only the MS level in which the
peak was identified.
chromPeakData(xchr)
Next we plot the identified chromatographic peaks in the extracted ion chromatogram. We use the col
parameter to color the individual chromatogram lines. Colors can also be
specified for the identified peaks, peakCol
for the foreground/border color,
peakBg
for the background/fill color. One color has to be provided for each
chromatographic peak listed by chromPeaks
. Below we define a color to indicate
the sample group from which the sample is and use the sample information in the
peaks' "sample"
column to assign the correct color to each chromatographic
peak. More peak highlighting options are described further below.
sample_colors <- group_colors[xchr$sample_group] plot(xchr, col = sample_colors, peakBg = sample_colors[chromPeaks(xchr)[, "column"]])
Finally we perform the chromatographic peak detection on the full data set. Note
that we set the argument noise
to 5000
to reduce the run time of this
vignette. With this setting we consider only signals with a value larger than
5000 in the peak detection step.
cwp <- CentWaveParam(peakwidth = c(20, 80), noise = 5000) xdata <- findChromPeaks(raw_data, param = cwp)
The results are returned as an XCMSnExp
object which extends the
OnDiskMSnExp
object by storing also LC/GC-MS preprocessing results. This means
also that all methods to sub-set and filter the data or to access the (raw) data
are inherited from the OnDiskMSnExp
object and can thus be re-used. The
results from the chromatographic peak detection can be accessed with the
chromPeaks
method.
head(chromPeaks(xdata))
The returned matrix
provides the m/z and retention time range for each
identified chromatographic peak as well as the integrated signal intensity
("into") and the maximal peak intensitity ("maxo"). Columns "sample" contains
the index of the sample in the object/experiment in which the peak was
identified.
Annotations for each individual peak can be extracted with the chromPeakData
function. This data frame could also be used to add/store arbitrary annotations
for each detected peak.
chromPeakData(xdata)
Below we use the data from the chromPeaks
matrix to calculate some per-file
summaries.
summary_fun <- function(z) c(peak_count = nrow(z), rt = quantile(z[, "rtmax"] - z[, "rtmin"])) T <- lapply(split.data.frame( chromPeaks(xdata), f = chromPeaks(xdata)[, "sample"]), FUN = summary_fun) T <- do.call(rbind, T) rownames(T) <- basename(fileNames(xdata)) pandoc.table(T, caption = paste0("Summary statistics on identified chromatographic", " peaks. Shown are number of identified peaks per", " sample and widths/duration of chromatographic ", "peaks."))
We can also plot the location of the identified chromatographic peaks in the
m/z - retention time space for one file using the plotChromPeaks
function. Below we plot the chromatographic peaks for the 3rd sample.
plotChromPeaks(xdata, file = 3)
To get a global overview of the peak detection we can plot the frequency of identified peaks per file along the retention time axis. This allows to identify time periods along the MS run in which a higher number of peaks was identified and evaluate whether this is consistent across files.
plotChromPeakImage(xdata)
Next we highlight the identified chromatographic peaks for the example peak from
before. Evaluating such plots on a list of peaks corresponding to known peaks or
internal standards helps to ensure that peak detection settings were appropriate
and correctly identified the expected peaks. We extract the ion chromatogram
from the peak detection result object, which contains then also the identified
chromatographic peaks for that ion that we can extract with the chromPeaks
function.
chr_ex <- chromatogram(xdata, mz = mzr, rt = rtr) chromPeaks(chr_ex)
We can also plot the extracted ion chromatogram. Identified chromatographic peaks will be automatically highlighted in the plot. Below we highlight chromatographic peaks with a rectangle from the peak's minimal to maximal rt and from an intensity of 0 to the maximal signal of the peak.
sample_colors <- group_colors[chr_ex$sample_group] plot(chr_ex, col = sample_colors, peakType = "rectangle", peakCol = sample_colors[chromPeaks(chr_ex)[, "sample"]], peakBg = NA)
Alternatively to the rectangle visualization above, it is possible to represent
the apex position of each peak with a single point (passing argument
type = "point"
to the function), or draw the actually identified peak by
specifying type = "polygon"
. To completely omit highlighting the identified
peaks (e.g. to plot base peak chromatograms or similar) type = "none"
can be
used. Below we use type = "polygon"
to fill the peak area
for each identified chromatographic peak in each sample. Whether individual
peaks can be still identified in such a plot depends however on the number of
samples from which peaks are drawn.
plot(chr_ex, col = group_colors[chr_raw$sample_group], lwd = 2, peakBg = sample_colors[chromPeaks(chr_ex)[, "sample"]])
Note that we can also specifically extract identified chromatographic peaks for
a selected region by providing the respective m/z and retention time ranges with
the mz
and rt
arguments in the chromPeaks
method.
pander(chromPeaks(xdata, mz = mzr, rt = rtr), caption = paste("Identified chromatographic peaks in a selected ", "m/z and retention time range."))
Finally we plot also the distribution of peak intensity per sample. This allows to investigate whether systematic differences in peak signals between samples are present.
## Extract a list of per-sample peak intensities (in log2 scale) ints <- split(log2(chromPeaks(xdata)[, "into"]), f = chromPeaks(xdata)[, "sample"]) boxplot(ints, varwidth = TRUE, col = group_colors[xdata$sample_group], ylab = expression(log[2]~intensity), main = "Peak intensities") grid(nx = NA, ny = NULL)
The time at which analytes elute in the chromatography can vary between samples (and even compounds). Such a difference was already observable in the extracted ion chromatogram plot shown as an example in the previous section. The alignment step, also referred to as retention time correction, aims at adjusting this by shifting signals along the retention time axis to align the signals between different samples within an experiment.
A plethora of alignment algorithms exist (see [@Smith:2013gr]), with some of
them being implemented also in xcms
. The method to perform the
alignment/retention time correction in xcms
is adjustRtime
which uses
different alignment algorithms depending on the provided parameter class.
In the example below we use the obiwarp method [@Prince:2006jj] to align the
samples. We use a binSize = 0.6
which creates warping functions in mz bins of
0.6. Also here it is advisable to modify the settings for each experiment and
evaluate if retention time correction did align internal controls or known
compounds properly.
xdata <- adjustRtime(xdata, param = ObiwarpParam(binSize = 0.6))
adjustRtime
, besides calculating adjusted retention times for each spectrum,
does also adjust the reported retention times of the identified chromatographic
peaks.
To extract the adjusted retention times we can use the adjustedRtime
method,
or simply the rtime
method that, if present, returns by default adjusted
retention times from an XCMSnExp
object.
## Extract adjusted retention times head(adjustedRtime(xdata)) ## Or simply use the rtime method head(rtime(xdata))
Raw retention times can be extracted from an XCMSnExp
containing
aligned data with rtime(xdata, adjusted = FALSE)
.
To evaluate the impact of the alignment we plot the BPC on the adjusted data. In
addition we plot the differences of the adjusted- to the raw retention times per
sample using the plotAdjustedRtime
function. Note that we don't want to
highlight any chromatographic peaks (because there would simply be too many) and
set thus peakType = "none"
in the plot
call.
## Get the base peak chromatograms. bpis_adj <- chromatogram(xdata, aggregationFun = "max") par(mfrow = c(2, 1), mar = c(4.5, 4.2, 1, 0.5)) plot(bpis_adj, col = group_colors[bpis_adj$sample_group], peakType = "none") ## Plot also the difference of adjusted to raw retention time. plotAdjustedRtime(xdata, col = group_colors[xdata$sample_group])
Too large differences between adjusted and raw retention times could indicate poorly performing samples or alignment.
Alternatively to obiwarp we could use the peak groups alignment method that
adjusts the retention time by aligning previously identified hook peaks
(chromatographic peaks present in most/all samples). Ideally, these hook peaks
should span most part of the retention time range. Below we first restore the
raw retention times (also of the identified peaks) using the dropAdjustedRtime
methods. Note that a drop*
method is available for each preprocessing step
allowing to remove the respective results from the XCMSnExp
object.
## Does the object have adjusted retention times? hasAdjustedRtime(xdata) ## Drop the alignment results. xdata <- dropAdjustedRtime(xdata) ## Does the object have adjusted retention times? hasAdjustedRtime(xdata)
Note: XCMSnExp
objects hold the raw along with the adjusted retention
times and subsetting will in most cases drop the adjusted retention
times. Sometimes it might thus be useful to replace the raw retention times
with the adjusted retention times. This can be done with the
applyAdjustedRtime
.
As noted above the peak groups method requires peak groups (features) present
in most samples to perform the alignment. We thus have to perform a first
correspondence run to identify such peaks (details about the algorithm used are
presented in the next section). We use here again default settings, but it is
strongly advised to adapt the parameters for each data set. The definition of
the sample groups (i.e. assignment of individual samples to the sample groups in
the experiment) is mandatory for the PeakDensityParam
. If there are no sample
groups in the experiment sampleGroups
should be set to a single value for each
file (e.g. rep(1, length(fileNames(xdata))
).
## Correspondence: group peaks across samples. pdp <- PeakDensityParam(sampleGroups = xdata$sample_group, minFraction = 0.8) xdata <- groupChromPeaks(xdata, param = pdp) ## Now the retention time correction. pgp <- PeakGroupsParam(minFraction = 0.85) ## Get the peak groups that would be used for alignment. xdata <- adjustRtime(xdata, param = pgp)
Note also that we could use the adjustRtimePeakGroups
method on the object
before alignment to evaluate on which features (peak groups) the alignment would
be performed. This can be useful to test different settings for the peak groups
algorithm. Also, it is possible to manually select or define certain peak groups
(i.e. their retention times per sample) and provide this matrix to the
PeakGroupsParam
class with the peakGroupsMatrix
argument.
Below plot the difference between raw and adjusted retention times using the
plotAdjustedRtime
function, which, if the peak groups method is used for
alignment, also highlights the peak groups used in the adjustment.
## Plot the difference of adjusted to raw retention time. plotAdjustedRtime(xdata, col = group_colors[xdata$sample_group], peakGroupsCol = "grey", peakGroupsPch = 1)
At last we evaluate the impact of the alignment on the test peak.
par(mfrow = c(2, 1)) ## Plot the raw data plot(chr_raw, col = group_colors[chr_raw$sample_group]) ## Extract the chromatogram from the adjusted object chr_adj <- chromatogram(xdata, rt = rtr, mz = mzr) plot(chr_adj, col = group_colors[chr_raw$sample_group], peakType = "none")
In some experiments it might be helpful to perform the alignment based on only a
subset of the samples, e.g. if QC samples were injected at regular intervals or
if the experiment contains blanks. Alignment method in xcms
allow to
estimate retention time drifts on a subset of samples (either all samples
excluding blanks or QC samples injected at regular intervals during a
measurement run) and use these to adjust the full data set.
Parameters subset
(of the PeakGroupsParam
or ObiwarpParam
object) can be
used to define the subset of samples on which the alignment of the full data set
will be based (e.g. subset
being the index of QC samples), and parameter
subsetAdjust
allows to specify the method by which the left-out samples will
be adjusted. There are currently two options available:
subsetAdjust = "previous"
: adjust the retention times of a non-subset
sample based on the alignment results of the previous subset sample (e.g. a
QC sample). If samples are e.g. in the order A1, B1, B2, A2, B3,
B4 with A representing QC samples and B study samples, using
subset = c(1, 4)
and subsetAdjust = "previous"
would result in all A
samples to be aligned with each other and non-subset samples B1 and B2
being adjusted based on the alignment result of subset samples A1 and B3
and B4 on those of A2.
subsetAdjust = "average"
: adjust retention times of non-subset samples based
on an interpolation of the alignment results of the previous and subsequent
subset sample. In the example above, B1 would be adjusted based on the
average of adjusted retention times between subset (QC) samples A1 and
A2. Since there is no subset sample after non-subset samples B3 and B4
these will be adjusted based on the alignment results of A2 alone. Note
that a weighted average is used to calculate the adjusted retention time
averages, which uses the inverse of the difference of the index of the
non-subset sample to the subset samples as weights. Thus, if we have a
setup like A1, B1, B2, A2 the adjusted retention times of A1
would get a larger weight than those of A2 in the adjustment of
non-subset sample B1 causing it's adjusted retention times to be closer
to those of A1 than to A2. See below for examples.
Both cases require a meaningful/correct ordering of the samples within the object (e.g. ordering by injection index).
The examples below aim to illustrate the effect of these alignment options.
First we assume samples 1, 6 and 11 in the faahKO data set to be QC samples
(sample pools). We thus want to perform the alignment based on these samples and
subsequently adjust the retention times of the left-out samples (2, 3, 4, 5, 7,
8, 9, 10 and 12) based on interpolation of the results from the neighboring
subset samples. After initial peak grouping we perform below the alignment
with the peak groups method passing the indices of the samples on which we
want the alignment to be based with the subset
argument and specify
subsetAdjust = "average"
to adjust the study samples based on interpolation
of the alignment results from neighboring subset/QC samples.
Note that for any subset-alignment all parameters such as minFraction
are
relative to the subset
, not the full experiment!
xdata_subs <- dropAdjustedRtime(xdata) ## Define the experimental layout xdata_subs$sample_type <- "study" xdata_subs$sample_type[c(1, 6, 11)] <- "QC" ## Initial peak grouping. Use sample_type as grouping variable pdp_subs <- PeakDensityParam(sampleGroups = xdata_subs$sample_type, minFraction = 0.9) xdata_subs <- groupChromPeaks(xdata_subs, param = pdp_subs) ## Define subset-alignment options and perform the alignment pgp_subs <- PeakGroupsParam(minFraction = 0.85, subset = which(xdata_subs$sample_type == "QC"), subsetAdjust = "average", span = 0.4) xdata_subs <- adjustRtime(xdata_subs, param = pgp_subs)
To illustrate the alignment results we plot the results only for samples 1 to 6
(1 and 6 being QC samples and 2 to 5 study samples that were adjusted based on
the QC samples). This nicely shows how the interpolation of
the subsetAdjust = "average"
works: retention times of sample 2 are adjusted
based on those from subset sample 1 and 6, giving however more weight to the
closer subset sample 1 which results in the adjusted retention times of 2 being
more similar to those of sample 1. Sample 5 on the other hand gets adjusted
giving more weight to the second subset sample (6).
clrs <- rep(NA, 12) clrs[1:6] <- paste0(brewer.pal(6, "Dark2"), 80) plotAdjustedRtime(xdata_subs, col = clrs, lwd = 2, peakGroupsCol = NA) legend("topleft", legend = 1:6, col = brewer.pal(6, "Dark2"), lwd = 2)
We also plot the full alignment results, drawing the subset
samples as green
and study samples as grey lines.
clrs <- rep("#00000040", 12) clrs[xdata_subs$sample_type == "QC"] <- c("#00ce0080") par(mfrow = c(2, 1), mar = c(4, 4.5, 1, 0.5)) plot(chromatogram(xdata_subs, aggregationFun = "sum"), col = clrs, peakType = "none") plotAdjustedRtime(xdata_subs, col = clrs, peakGroupsPch = 1, peakGroupsCol = "#00ce0040")
Option subsetAdjust = "previous"
adjusts the retention times of a non-subset
sample based on a single subset sample (the previous), which results in most
cases in the adjusted retention times of the non-subset sample being highly
similar to those of the subset sample which was used for adjustment.
Also obiwarp alignment supports the same types of subset-alignment as shown below.
xdata_subs <- dropAdjustedRtime(xdata_subs) prm <- ObiwarpParam(subset = which(xdata_subs$sample_type == "QC"), subsetAdjust = "average") xdata_subs <- adjustRtime(xdata_subs, param = prm)
We again plot the results.
clrs <- rep("#00000040", 12) clrs[which(xdata_subs$sample_type == "QC")] <- "#00ce0080" par(mfrow = c(2, 1), mar = c(4, 4.5, 1, 0.5)) plot(chromatogram(xdata_subs, aggregationFun = "sum"), col = clrs, peakType = "none") plotAdjustedRtime(xdata_subs, col = clrs, peakGroupsPch = 1)
The final step in the metabolomics preprocessing is the correspondence that
matches detected chromatographic peaks between samples (and depending on the
settings, also within samples if they are adjacent). The method to perform the
correspondence in xcms
is groupChromPeaks
. We will use the peak density
method [@Smith:2006ic] to group chromatographic peaks. The algorithm combines
chromatographic peaks depending on the density of peaks along the retention time
axis within small slices along the mz dimension. To illustrate this we plot
below the chromatogram for an mz slice with multiple chromatographic peaks
within each sample. We use below a value of 0.4 for the minFraction
parameter
hence only chromatographic peaks present in at least 40% of the samples per
sample group are grouped into a feature. The sample group assignment is
specified with the sampleGroups
argument.
## Define the mz slice. mzr <- c(305.05, 305.15) ## Extract and plot the chromatograms chr_mzr <- chromatogram(xdata, mz = mzr, rt = c(2500, 4000)) par(mfrow = c(3, 1), mar = c(1, 4, 1, 0.5)) cols <- group_colors[chr_mzr$sample_group] plot(chr_mzr, col = cols, xaxt = "n", xlab = "", peakBg = sample_colors[chromPeaks(chr_mzr)[, "sample"]]) ## Define the parameters for the peak density method pdp <- PeakDensityParam(sampleGroups = xdata$sample_group, minFraction = 0.4, bw = 30) par(mar = c(4, 4, 1, 0.5)) plotChromPeakDensity(xdata, mz = mzr, col = cols, param = pdp, pch = 16, xlim = c(2500, 4000)) ## Use a different bw pdp <- PeakDensityParam(sampleGroups = xdata$sample_group, minFraction = 0.4, bw = 20) plotChromPeakDensity(xdata, mz = mzr, col = cols, param = pdp, pch = 16, xlim = c(2500, 4000))
The upper panel in the plot above shows the extracted ion chromatogram for each
sample with the detected peaks highlighted. The middle and lower plot shows the
retention time for each detected peak within the different samples. The black
solid line represents the density distribution of detected peaks along the
retention times. Peaks combined into features (peak groups) are indicated with
grey rectangles. Different values for the bw
parameter of the
PeakDensityParam
were used:bw = 30
in the middle and bw = 20
in the lower
panel. With the default value for the parameter bw
the two neighboring
chromatographic peaks would be grouped into the same feature, while with a bw
of 20 they would be grouped into separate features. This grouping depends on
the parameters for the density function and other parameters passed to the
algorithm with the PeakDensityParam
.
## Perform the correspondence pdp <- PeakDensityParam(sampleGroups = xdata$sample_group, minFraction = 0.4, bw = 20) xdata <- groupChromPeaks(xdata, param = pdp)
The results from the correspondence can be extracted using the
featureDefinitions
method, that returns a DataFrame
with the definition of
the features (i.e. the mz and rt ranges and, in column peakidx
, the index of
the chromatographic peaks in the chromPeaks
matrix for each feature).
## Extract the feature definitions featureDefinitions(xdata)
The featureValues
method returns a matrix
with rows being features and
columns samples. The content of this matrix can be defined using the value
argument. The default isvalue = "index"
which simply returns the index of the
peak (in the chromPeaks
matrix) assigned to a feature in a sample. Setting
value = "into"
returns a matrix with the integrated signal of the peaks
corresponding to a feature in a sample. Any column name of the chromPeaks
matrix can be passed to the argument value
. Below we extract the integrated
peak intensity per feature/sample.
## Extract the into column for each feature. head(featureValues(xdata, value = "into"))
This feature matrix contains NA
for samples in which no chromatographic peak
was detected in the feature's m/z-rt region. While in many cases there might
indeed be no peak signal in the respective region, it might also be that there
is signal, but the peak detection algorithm failed to detect a chromatographic
peak. xcms
provides the fillChromPeaks
method to fill in intensity data
for such missing values from the original files. The filled in peaks are added
to the chromPeaks
matrix and get a TRUE
value in the "is_filled"
column of
the chromPeakData
data frame. Below we perform such a filling-in of missing
peaks.
## Filling missing peaks using default settings. Alternatively we could ## pass a FillChromPeaksParam object to the method. xdata <- fillChromPeaks(xdata) head(featureValues(xdata))
For features without detected peaks in a sample, the method extracts all
intensities in the mz-rt region of the feature, integrates the signal and adds a
filled-in peak to the chromPeaks
matrix. No peak is added if no signal is
measured/available for the mz-rt region of the feature. For these, even after
filling in missing peak data, a NA
is reported in the featureValues
matrix.
It should be mentioned that fillChromPeaks
uses columns "rtmin"
, "rtmax"
,
"mzmin"
and "mzmax"
from the featureDefinitions
table to define the region
from which the signal should be integrated to generate the filled-in peak
signal. These values correspond however to the positions of the peak apex not
the peak boundaries of all chromatographic peaks assigned to a feature. It might
be advisable to increase this area in retention time dimension by a constant
value appropriate to the average peak width in the experiment. Such a value can
be specified with fixedRt
of the FillChromPeaksParam
. If the average peak
width in the experiment is 20 seconds, specifyingfixedRt = 10
ensures that the area
from which peaks are integrated is at least 20 seconds wide.
Below we compare the number of missing values before and after filling in
missing values. We can use the parameter filled
of the featureValues
method
to define whether or not filled-in peak values should be returned too.
## Missing values before filling in peaks apply(featureValues(xdata, filled = FALSE), MARGIN = 2, FUN = function(z) sum(is.na(z))) ## Missing values after filling in peaks apply(featureValues(xdata), MARGIN = 2, FUN = function(z) sum(is.na(z)))
Next we use the featureSummary
function to get a general per-feature summary
that includes the number of samples in which a peak was found or the number of
samples in which more than one peak was assigned to the feature. Specifying also
sample groups breaks down these summary statistics for each individual sample
group.
head(featureSummary(xdata, group = xdata$sample_group))
The performance of peak detection, alignment and correspondence should always be
evaluated by inspecting extracted ion chromatograms e.g. of known compounds,
internal standards or identified features in general. The featureChromatograms
function allows to extract chromatograms for each feature present in
featureDefinitions
. The returned Chromatograms
object contains an ion
chromatogram for each feature (each row containing the data for one feature) and
sample (each column representing containing data for one sample). Below we
extract the chromatograms for the first 4 features.
feature_chroms <- featureChromatograms(xdata, features = 1:4) feature_chroms
And plot the extracted ion chromatograms. We again use the group color for each identified peak to fill the area.
plot(feature_chroms, col = sample_colors, peakBg = sample_colors[chromPeaks(feature_chroms)[, "sample"]]) third <- feature_chroms[3, ] plot(third) chromPeaks(third) plot(feature_chroms[3, ], col = group_colors[feature_chroms$sample_group]) plot(feature_chroms[4, ], col = group_colors[feature_chroms$sample_group])
At last we perform a principal component analysis to evaluate the grouping of the samples in this experiment. Note that we did not perform any data normalization hence the grouping might (and will) also be influenced by technical biases.
## Extract the features and log2 transform them ft_ints <- log2(featureValues(xdata, value = "into")) ## Perform the PCA omitting all features with an NA in any of the ## samples. Also, the intensities are mean centered. pc <- prcomp(t(na.omit(ft_ints)), center = TRUE) ## Plot the PCA cols <- group_colors[xdata$sample_group] pcSummary <- summary(pc) plot(pc$x[, 1], pc$x[,2], pch = 21, main = "", xlab = paste0("PC1: ", format(pcSummary$importance[2, 1] * 100, digits = 3), " % variance"), ylab = paste0("PC2: ", format(pcSummary$importance[2, 2] * 100, digits = 3), " % variance"), col = "darkgrey", bg = cols, cex = 2) grid() text(pc$x[, 1], pc$x[,2], labels = xdata$sample_name, col = "darkgrey", pos = 3, cex = 2)
We can see the expected separation between the KO and WT samples on PC2. On PC1 samples separate based on their ID, samples with an ID <= 18 from samples with an ID > 18. This separation might be caused by a technical bias (e.g. measurements performed on different days/weeks) or due to biological properties of the mice analyzed (sex, age, litter mates etc).
Normalizing features' signal intensities is required, but at present not (yet)
supported in xcms
(some methods might be added in near future). Also, for the
identification of e.g. features with significant different
intensities/abundances it is suggested to use functionality provided in other R
packages, such as Bioconductor's excellent limma
package. To enable support
also for other packages that rely on the old xcmsSet
result object, it is
possible to coerce the new XCMSnExp
object to an xcmsSet
object using
xset <- as(x, "xcmsSet")
, with x
being an XCMSnExp
object.
For a detailed description of the new data objects and changes/improvements compared to the original user interface see the new_functionality vignette.
XCMSnExp
objects allow to capture all performed pre-processing steps along
with the used parameter class within the @processHistory
slot. Storing also
the parameter class ensures the highest possible degree of analysis
documentation and in future might enable to replay analyses or parts of it.
The list of all performed preprocessings can be extracted using the
processHistory
method.
processHistory(xdata)
It is also possible to extract specific processing steps by specifying its
type. Available types can be listed with the processHistoryTypes
function. Below we extract the parameter class for the alignment/retention time
adjustment step.
ph <- processHistory(xdata, type = "Retention time correction") ph
And we can also extract the parameter class used in this preprocessing step.
## Access the parameter processParam(ph[[1]])
XCMSnEx
objects can be subsetted/filtered using the [
method, or one of the
many filter*
methods. All these methods aim to ensure that the data in the
returned object is consistent. This means for example that if the object is
subsetted by selecting specific spectra (by using the [
method) all identified
chromatographic peaks are removed. Correspondence results (i.e. identified
features) are removed if the object is subsetted to contain only data from
selected files (using the filterFile
method). This is because the
correspondence results depend on the files on which the analysis was performed -
running a correspondence on a subset of the files would lead to different
results.
As an exception, it is possible to force keeping adjusted retention times in the
subsetted object setting the keepAdjustedRtime
argument to TRUE
in any of
the subsetting methods.
Below we subset our results object the data for the files 2 and 4.
subs <- filterFile(xdata, file = c(2, 4)) ## Do we have identified chromatographic peaks? hasChromPeaks(subs)
Peak detection is performed separately on each file, thus the subsetted object contains all identified chromatographic peaks from the two files. However, we used a retention time adjustment (alignment) that was based on available features. All features have however been removed and also the adjusted retention times (since the alignment based on features that were identified on chromatographic peaks on all files).
## Do we still have features? hasFeatures(subs) ## Do we still have adjusted retention times? hasAdjustedRtime(subs)
We can however use the keepAdjustedRtime
argument to force keeping the
adjusted retention times.
subs <- filterFile(xdata, keepAdjustedRtime = TRUE) hasAdjustedRtime(subs)
The filterRt
method can be used to subset the object to spectra within a
certain retention time range.
subs <- filterRt(xdata, rt = c(3000, 3500)) range(rtime(subs))
Filtering by retention time does not change/affect adjusted retention times (also, if adjusted retention times are present, the filtering is performed on the adjusted retention times).
hasAdjustedRtime(subs)
Also, we have all identified chromatographic peaks within the specified retention time range:
hasChromPeaks(subs) range(chromPeaks(subs)[, "rt"])
The most natural way to subset any object in R is with [
. Using [
on an
XCMSnExp
object subsets it keeping only the selected spectra. The index i
used in [
has thus to be an integer between 1 and the total number of spectra
(across all files). Below we subset xdata
using both [
and filterFile
to
keep all spectra from one file.
## Extract all data from the 3rd file. one_file <- filterFile(xdata, file = 3) one_file_2 <- xdata[fromFile(xdata) == 3] ## Is the content the same? all.equal(spectra(one_file), spectra(one_file_2))
While the spectra-content is the same in both objects, one_file
contains also
the identified chromatographic peaks while one_file_2
does not. Thus, in most
situations subsetting using one of the filter functions is preferred over the
use of [
.
## Subsetting with filterFile preserves chromatographic peaks head(chromPeaks(one_file)) ## Subsetting with [ not head(chromPeaks(one_file_2))
Note however that also [
does support the keepAdjustedRtime
argument. Below
we subset the object to spectra 20:30.
subs <- xdata[20:30, keepAdjustedRtime = TRUE] hasAdjustedRtime(subs) ## Access adjusted retention times: rtime(subs) ## Access raw retention times: rtime(subs, adjusted = FALSE)
As with MSnExp
and OnDiskMSnExp
objects, [[
can be used to extract a
single spectrum object from an XCMSnExp
object. The retention time of the
spectrum corresponds to the adjusted retention time if present.
## Extract a single spectrum
xdata[[14]]
At last we can also use the split
method that allows to split an XCMSnExp
based on a provided factor f
. Below we split xdata
per file. Using
keepAdjustedRtime = TRUE
ensures that adjusted retention times are not
removed.
x_list <- split(xdata, f = fromFile(xdata), keepAdjustedRtime = TRUE) lengths(x_list) lapply(x_list, hasAdjustedRtime)
Note however that there is also a dedicated splitByFile
method instead for
that operation, that internally uses filterFile
and hence does e.g. not remove
identified chromatographic peaks. The method does not yet support the
keepAdjustedRtime
parameter and thus removes by default adjusted retention
times.
xdata_by_file <- splitByFile(xdata, f = factor(1:length(fileNames(xdata)))) lapply(xdata_by_file, hasChromPeaks)
Most methods in xcms
support parallel processing. Parallel processing is
handled and configured by the BiocParallel
Bioconductor package and can be
globally defined for an R session.
Unix-based systems (Linux, macOS) support multicore
-based parallel
processing. To configure it globally we register
the parameter class. Note also
that bpstart
is used below to initialize the parallel processes.
register(bpstart(MulticoreParam(2)))
Windows supports only socket-based parallel processing:
register(bpstart(SnowParam(2)))
Note that multicore
-based parallel processing might be buggy or failing on
macOS. If so, the DoparParam
could be used instead (requiring the foreach
package).
For other options and details see the vignettes from the BiocParallel
package.
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.