Description Usage Arguments Value See Also
Computes the lambda parameter of the Gauss distribution from energy loss for compatibility with CERN W5013 No effective projectile charge is considered!
1 2 | AT.lambda.Gauss.from.energy.loss(energy.loss.keV, E.MeV.u, particle.no,
material.no, slab.thickness.um)
|
energy.loss.keV |
Energy loss (array of size n). |
E.MeV.u |
energy of particle per nucleon (array of size n) (see also
|
particle.no |
particle index (array of size n) (see also
|
material.no |
material index (see also |
slab.thickness.um |
slab thickness in um (array of size n). |
lambda.gauss |
(array of size n) |
View the C source code here: http://sourceforge.net/apps/trac/libamtrack/browser/trunk/src/AT_EnergyLoss.c#L403
Add the following code to your website.