Description Usage Arguments Value Author(s) References See Also Examples
Computes the seawater isothermal compressibility, 1/Pa
1 | sw_kappa_t(S = 35, t = 25, p = P-1.013253, P = 1.013253)
|
S |
Absolute salinity (g/kg), |
t |
Temperature, degrees C, |
p |
gauge or applied pressure, pressure referenced against the local atmospheric pressure, bar |
P |
true pressure, bar |
isothermal compressibility, 1/Pa.
Karline Soetaert <karline.soetaert@nioz.nl>
Feistel R, 2008. A Gibbs function for seawater thermodynamics for -6 to 80 dgC and salinity up to 120 g/kg. Deep-Sea Research I, 55, 1639-1671.
McDougall TJ, Feistel R, Millero FJ, Jackett DR, Wright DG, King BA, Marion GM, Chen C-T A and Spitzer P, 2009. Calculation of the Thermophysical Properties of Seawater, Global Ship-based Repeat Hydrography Manual, IOCCP Report No. 14, ICPO Publication Series no. 134.
sw_adtgrad, sw_alpha, sw_beta,
sw_comp, sw_conserv, sw_cp,
sw_dens,
sw_depth, sw_enthalpy, sw_entropy,
sw_gibbs, sw_kappa, sw_sfac,
sw_svel, sw_tfreeze, sw_tpot
convert_PStoAS, to convert from practical salinity (-) to
absolute salinity (g/kg)
1 | sw_kappa_t(35.7, 25.5, 102.3) #4.10403794615135e-6
|
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.