Nothing
# Plan fck_EN-206 and manually specified OC curve
# f_ck is stored in DefectLimitLower and must always be set, ConformityParam
# only contains c(n) or c(n, N)
# Run with: devtools::test(filter = "bug-qualcon-manual")
test_that("QCM-1: fck_EN-206 without a finite DefectLimitLower stops with a clear message", {
th <- c(0, 1)
pa <- c(1, 1)
hp <- c(3.65, 0.12, 3, 10)
expect_error(
.oc_get_outgoing_pdf(th, pa, "fck_EN-206", numeric(0), "lt", hp),
"DefectLimitLower"
)
expect_error(
.oc_get_outgoing_pdf(th, pa, "fck_EN-206", c(15), "lt", hp, lower = -Inf),
"f_ck"
)
})
test_that("QCM-2: fck_EN-206 rejects an upper defect limit", {
th <- c(0, 1)
pa <- c(1, 1)
hp <- c(3.65, 0.12, 3, 10)
expect_error(
.oc_get_outgoing_pdf(th, pa, "fck_EN-206", c(15), "lt", hp, lower = 25, upper = 40),
"DefectLimitUpper"
)
})
test_that("QCM-3: manual OC curve without selection (P_a = 1) works without ConformityParam (lt)", {
th <- c(0, 1)
pa <- c(1, 1)
hp <- c(3.65, 0.12, 3, 10)
r <- .oc_get_outgoing_pdf(th, pa, "fck_EN-206", numeric(0), "lt", hp, lower = 25)
expect_true(all(is.finite(r$f_o)))
expect_true(is.finite(r$m_o))
expect_gt(r$s_o, 0)
})
test_that("QCM-4: manual OC curve without selection does not depend on the chosen f_ck", {
th <- c(0, 1)
pa <- c(1, 1)
hp <- c(30, 2, 3, 10)
r_a <- .oc_get_outgoing_pdf(th, pa, "fck_EN-206", numeric(0), "st", hp, lower = 25)
r_b <- .oc_get_outgoing_pdf(th, pa, "fck_EN-206", numeric(0), "st", hp, lower = 20)
expect_equal(r_a$m_o, r_b$m_o, tolerance = 1e-10)
expect_equal(r_a$s_o, r_b$s_o, tolerance = 1e-10)
})
test_that("QCM-5: updateBasevar() with a manual OC curve and DefectLimitLower runs", {
v <- PROB_BASEVAR$new(Name = "fc", DistributionType = "lt",
DistributionParameters = c(3.65, 0.12, 3, 10))
qc <- PROB_QUALCON$new(Name = "manual", ConformityType = "fck_EN-206",
DefectLimitLower = 25,
theta_grid = c(0, 1), Pa_grid = c(1, 1))
post <- NULL
expect_no_error(suppressMessages(suppressWarnings(
post <- v$updateBasevar(PROB_QUALCON = qc, min_r2 = 0.9)
)))
expect_true(is.finite(post$Mean))
expect_gt(post$Sd, 0)
})
test_that("QCM-6: updateBasevar() with a manual OC curve and without DefectLimitLower stops", {
v <- PROB_BASEVAR$new(Name = "fc", DistributionType = "lt",
DistributionParameters = c(3.65, 0.12, 3, 10))
qc <- PROB_QUALCON$new(Name = "manual", ConformityType = "fck_EN-206",
theta_grid = c(0, 1), Pa_grid = c(1, 1))
expect_error(
suppressMessages(suppressWarnings(v$updateBasevar(PROB_QUALCON = qc))),
"DefectLimitLower"
)
})
test_that("QCM-7: OC curve of fck_EN-206 uses DefectLimitLower as f_ck", {
th <- c(0.05, 0.2)
hp <- c(3.75, 0.105, 3, 10)
set.seed(1)
pa_25 <- .oc_compute_pa(th, "fck_EN-206", 5, "lt", hp, lower = 25, N = 5000)
set.seed(1)
pa_40 <- .oc_compute_pa(th, "fck_EN-206", 5, "lt", hp, lower = 40, N = 5000)
expect_false(isTRUE(all.equal(pa_25, pa_40)))
expect_true(all(pa_25 >= 0 & pa_25 <= 1))
})
test_that("QCM-8: OC curve of fck_EN-206 without n or without f_ck stops", {
th <- c(0.05, 0.2)
hp <- c(30, 3)
expect_error(.oc_compute_pa(th, "fck_EN-206", numeric(0), "norm", hp, lower = 25), "must contain n")
expect_error(.oc_compute_pa(th, "fck_EN-206", c(5), "norm", hp), "DefectLimitLower")
})