Description Usage Arguments Details Value Examples
Main function to calculate f2 according to different regulatory guidelines.
1 2 3 4 5 6 7 | calcf2(test, ref, path.in, file.in, path.out, file.out,
regulation = c("EMA", "FDA", "WHO", "Canada", "ANVISA"),
cv.rule = TRUE, message = FALSE, min.points = 3L,
f2.type = c("est.f2", "exp.f2", "bc.f2", "vc.exp.f2",
"vc.bc.f2", "all"), both.TR.85 = FALSE,
digits = 2L, time.unit = c("min", "h"), plot = TRUE,
plot.start.time = 0, plot.max.unit = 24L)
|
test, ref |
Data frames of dissolution profiles of test and reference
product if |
path.in, file.in, path.out, file.out |
Character strings of input and output directories and file names. See Input/Output in Details. |
regulation |
Character strings indicating regulatory guidelines. See Regulation in Details. |
cv.rule |
Logical. If |
message |
Logical. If |
min.points |
An integer indicating the minimum time points to be used
to calculate f2. The default value 3 should be used for
conventional f2 calculation. This parameter is mainly used for
bootstrap f2 method. See Regulation in Details.
@seealso |
f2.type |
Character strings indicating which f2 estimators
should be calculated. For conventional f2 calculation, the
default |
both.TR.85 |
Logical. If |
digits |
An integer indicating the decimal points for the output. |
time.unit |
Character strings indicating the unit of time. It should
be either |
plot |
Logical. If |
plot.start.time |
Numeric value indicating the starting time for the plot. |
plot.max.unit |
Integer. If the number of individual units is no more
than this value, the mean and all individual profiles will be plotted;
otherwise, individual profiles will be represented by boxplots at each
time point. Therefore, to avoid overplotting, this value should not be
too large. @seealso |
Arguments test
and ref
must be provided by the user. They should be R
data frames
, with time as the first column, and all individual profiles
profiles as the rest columns, or mean profile as the second column if only
mean profile is available. The actual names of the columns do not matter
since they will be renamed internally.
The dissolution data of test and reference product can either be provided as
data frames for test
and ref
, as explained above, or be read from an
Excel file with data of test and reference stored in separate worksheets.
In the latter case, the argument path.in
, the directory where the Excel
file is, and file.in
, the name of the Excel file including the file
extension .xls
or .xlsx
, must be provided. In such case, the argument
test
and ref
must be the names of the worksheets in quotation marks.
The first column of each Excel worksheet must be time, and the rest columns
are individual dissolution profiles, or the second column must be mean
profile if only mean data is available. The first row should be column names,
such as time, unit01, unit02, ... The actual names of the columns do not
matter as they will be renamed internally.
Arguments path.out
and file.out
are the names of the output directory
and file. It is an overkill to output such simple calculations; therefore,
unless these two arguments are specified by the user, results are printed
on screen by default.
To apply f2 method, different regulatory guidelines have slightly different requirements. Some requirements are almost universal, such as same time points for the test and reference product, minimum 3 time points (excluding time zero), and twelve individual profiles for each formulation. Other requirements are slightly different among different regulatory guidelines, or at least interpreted differently. Two main issues are the rules for the variability (CV Rule) and time points where dissolution is more than 85% (85% Rule).
EMA
, Canada
, and ANVISA
: The CV of the first time point should not
be greater than 20%, and the CV of the rest time points should not be
greater than 10%.
WHO
: The CV should not be greater than 20% for time points up to
10 min, and not greater than 10% for the rest time points.
FDA
: US FDA is more flexible. The CV for the early time points should
not be greater than 20%, and for the rest time points, not greater than
10%.
The phrase the first time point in EMA
rule was later interpreted as all
time points up to 10 min, according to an unofficial communication with an
European regulator. This makes the EMA
rule the same as WHO
rule. For
example, if there are 5 min and 10 min time points in the dissolution
profiles, the CV for both 5 min and 10 min should not be greater than 20%.
The first time point in ANVISA
rule corresponds to 40% of the total
collected points. For example, for a dissolution profile with five
collection times, the first two collection times are considered first points.
The phrase early time points in FDA
rule is typically interpreted as
those points up to 15 min, sometimes even up to 20 min according to
an unofficial communication with FDA staff. In the function calcf2()
, the
cutting point for FDA rule is 15 min.
This rule is implemented as follows:
EMA
, FDA
, Canada
, and ANVISA
: Only one measurement is considered
after 85% of dissolution for any product.
WHO
: Dissolution profiles should be 'cut' at the time point where
the reference release more than 85%. Therefore, WHO
rule only differs
from rule of EMA
, FDA
, Canada
, and ANVISA
when test product
dissolve faster than reference. If reference product dissolve faster, then
rules of all five regulatory bodies are same in this regard.
The exact phrase in the guidance of US FDA regarding this rule is that "Only one measurement should be considered after 85% dissolution of both the products." Due to the ambiguous word "both" used in the sentence, the conventional interpretation was that all measurements up to the time point at which both test and reference dissolved more than 85% should be included in the calculation of f2. However, this is only true when both test and reference dissolve more than 85% at the same time points.
Consider the following example:
time | test | reference |
5 | 7 | 10 |
10 | 15 | 20 |
15 | 50 | 55 |
20 | 69 | 86 |
30 | 82 | 90 |
45 | 84 | 95 |
60 | 86 | 97 |
According to conventional interpretation, all measurements up to 60 min should be included to calculate f2 because both test and reference dissolved more than 85% only at 60 min, not at any earlier time point. However, in such case, there would be 4 measurement of reference (20, 30, 45, and 60 min) included in the calculation, which would be a direct contradictory to the phrase "Only one measurement should be considered after 85% ..." in the same statement in the guidance!
In an unofficial communication using this example, an FDA staff confirmed that only the first 4 time points (up to 20 min) would be used. In other words, FDA rule in this regard is the same as EMA rule.
The statement in ANVISA
guideline also uses the word "ambos" (means both),
which could also lead to the similar confusion. Follow the same logic as
demonstrated above, it should also be interpreted as the same rule in EMA
guideline.
Read vignette Introduction to bootf2 for more details.
A data frame of f2 type and f2 value, the
number of time points used for the calculation (f2.tp
), indication if
both test and reference dissolve more than 85% at 15 min (d85at15
), and
other information used for the calculation.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 | tp <- c(5, 10, 15, 20, 30, 45, 60)
mod.par.t <- list(fmax = 100, fmax.cv = 2, tlag = 0, tlag.cv = 0,
mdt = 20, mdt.cv = 5, beta = 2.2, beta.cv = 5)
d.t <- sim.dp(tp, model.par = mod.par.t, seed = 100, n.units = 120L,
plot = FALSE)$sim.disso
mod.par.r <- list(fmax = 100, fmax.cv = 2, tlag = 0, tlag.cv = 0,
mdt = 25, mdt.cv = 4, beta = 2.1, beta.cv = 3)
d.r <- sim.dp(tp, model.par = mod.par.r, seed = 100, n.units = 120L,
plot = FALSE)$sim.disso
# set `message = TRUE` to view the compliance of the regulatory guidelines.
calcf2(d.t, d.r, plot = FALSE)
|