powerplant: Tuefekci's powerplant data

Description Format Source References Examples

Description

The dataset contains 9568 data points collected from a Combined Cycle Power Plant over 6 years (2006-2011), when the power plant was set to work with full load. Features consist of hourly average ambient variables Temperature (T), Ambient Pressure (AP), Relative Humidity (RH) and Exhaust Vacuum (V) to predict the net hourly electrical energy output (EP) of the plant.

A combined cycle power plant (CCPP) is composed of gas turbines (GT), steam turbines (ST) and heat recovery steam generators. In a CCPP, the electricity is generated by gas and steam turbines, which are combined in one cycle, and is transferred from one turbine to another. While the Vacuum is collected from and has effect on the Steam Turbine, the other three of the ambient variables affect the GT performance.

Format

9568 observations on 5 continuous variables.

Source

UCI repository. https://archive.ics.uci.edu/ml/datasets/Combined+Cycle+Power+Plant

References

Tuefekci, P. (2014), Prediction of full load electrical power output of a base load operated combined cycle power plant using machine learning methods, International Journal of Electrical Power & Energy Systems, 60, pp. 126-140, ISSN 0142-0615.

Examples

1
2

Example output

     AT     V      AP    RH     PE
1  8.34 40.77 1010.84 90.01 480.48
2 23.64 58.49 1011.40 74.20 445.75
3 29.74 56.90 1007.15 41.91 438.76
4 19.07 49.69 1007.22 76.79 453.09
5 11.80 40.66 1017.13 97.20 464.43
6 13.97 39.16 1016.05 84.60 470.96

condvis documentation built on May 2, 2019, 5:57 a.m.