Description Usage Format Source
The information for this pumping test is:
Radius of the well (in m): rw <- 0.6096
Radius of the casing (in m): rc <- 0.6096
Distance to pumping well (in m): r <- 3.048
Pumping Rate (in m3/s): Q <- 0.0050472
1 |
A data frame with 46 rows and 2 variables:
time, in seconds
drawdown, in meters
Hall, P. Water well and aquifer test analysis 1996, Water Resources Publications, LLC, 412 pp. Pages 171-174.
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.