Description Usage Format Source
A dataset containing the time and drawdowns of a pumping test in a confined aquifer. The information for this pumping test is:
Pumping rate (in m3/s): Q <- 1.3888e-2
Distance to pumping well (in m): r <- 250
1 |
A data frame with 22 rows and 2 variables:
time, in seconds
drawdown, in meters
C.W. Fetter, 2001, Applied Hydrogeology, Fourth Edition. Prentice Hall, Upper Saddle River, 598 pp. Table 5.1, page 172
Add the following code to your website.
For more information on customizing the embed code, read Embedding Snippets.