Description Usage Format Source
The information of this pumping test is:
Distance to observation well (r): 5 m
Pumping rate history: - Step 1: 300s-1800s, 0.00578 m3/s - Step 2: 2100s-4800s, 0.0081 m3/s - Step 3: 5400s-7800s, 0.0069 m3/s
1 |
A data frame with 18 rows and 2 variables
time in seconds
Drawdown in m
Kruseman and de Ridder. 1994. Analysis and Evaluation of pumping test data. Second Edition pp. 185.