#' Bearing capacity factor Ngamma
#' @description Taken from "geotech" package. Calculate the bearing capacity factor Ngamma using either the Terzaghi or Vesic methods.
#' @param phi Friction angle in degrees
#' @param case "general" or "local" to indicate general or local shear failure ("general" is default)
#' @param method "Terzaghi" or "Vesic" ("Terzaghi" is default)
#'
#' @return Bearing capacity factor
#' @export
#'
#' @references Coduto, D.P., Kitch, W.A., and Yeung, M.R. (2016). Foundation Design: Principles and Practices, Pearson, Boston.
#' @references Terzaghi, K. (1943). Theoretical Soil Mechanics, John Wiley, New York
#' @references Vesic, A.S. (1973). Analysis of Ultimate Loads of Shallow Foundations, ASCE Journal of the Soil Mechanics and Foundations Division, Vol. 99, No. SM1, pp. 45-73.
#'
#' @examples
#' Ngamma(phi = 20, case = "local", method = "Terzaghi")
#'
Ngamma = function (phi, case = "general", method = "Terzaghi")
{
if (case != "general" && case != "local")
stop("Case may only be 'general' or 'local'.")
if (method != "Terzaghi" && method != "Vesic")
stop("Case may only be 'Terzaghi' or 'Vesic'.")
if (case == "local")
phi <- atan(2/3 * tan(phi * pi/180)) * 180/pi
phi.deg <- phi
phi.rad <- phi * pi/180
if (method == "Terzaghi") {
Nq.value <- Nq(phi = phi.deg, case = "general", method = "Terzaghi")
num <- 2 * (Nq.value + 1) * tan(phi.rad)
den <- 1 + 0.4 * sin(4 * phi.rad)
Ngamma.value <- num/den
}
else {
if (method == "Vesic") {
Nq.value <- Nq(phi = phi.deg, case = "general", method = "Vesic")
Ngamma.value <- 2 * (Nq.value + 1) * tan(phi.rad)
}
}
return(Ngamma.value)
}