For a set of FCS files, flow_auto_qc performs a complete and automatic quality control. It consists in the detection and removal of anomalies by checking three properties of flow cytometry: 1) flow rate, 2) signal acquisition, 3) dynamic range.
1 2 3 4 5 6 | cytosee_flowAI(fcsfiles, remove_from = "all", output = 1, timeCh = NULL,
second_fractionFR = 0.1, alphaFR = 0.01, decompFR = TRUE,
ChRemoveFS = c("FSC", "SSC"), outlierFS = FALSE, pen_valueFS = 200,
max_cptFS = 3, ChFM = NULL, sideFM = "both", neg_valuesFM = 1,
html_report = "_QC", mini_report = "QCmini", fcs_QC = "_QC",
fcs_highQ = FALSE, fcs_lowQ = FALSE, folder_results = "resultsQC")
|
fcsfiles |
It can be a character vector with the filenames of the FCS files, a flowSet or a flowFrame. |
remove_from |
Select from which of the three steps the anomalies have to be
excluded in the high quality FCS file. The default option |
output |
Set it to 1 to return a flowFrame or a flowSet with high quality events only.
Set it to 2 to return a flowFrame or a flowSet with an additional
parameter where the low quality events have a value higher than 10,000.
Set it to 3 to return a list with the IDs of low quality cells. Set it to any other
value if no R object has to be returned. Default is |
timeCh |
Character string corresponding to the name of the Time Channel
in the set of FCS files. By default is |
second_fractionFR |
The fraction of a second that is used to split
the time channel in order to recreate the flow rate. Set it to
|
alphaFR |
The level of statistical significance used to
accept anomalies detected by the ESD method. The default value is |
decompFR |
Logical indicating whether the flow rate should be decomposed
in the trend and cyclical components. Default is |
ChRemoveFS |
Add a character vector with the names or name portions
of the channels that you want to exclude from the signal acquisition check.
The default option, |
outlierFS |
logical indicating whether outliers have to be removed
before the changepoint detection of the signal acquisition check.
The default is |
pen_valueFS |
The value of the penalty for the changepoint detection
algorithm. This can be a numeric value or text giving the formula to use;
for instance, you can use the character string |
max_cptFS |
The maximum number of changepoints that can be detected
for each channel. The default is |
ChFM |
A character vector that indicates which channels need to include
for the dynamic range check. The default option is |
sideFM |
Select whether the dynamic range check has to be executed on
both limits, the upper limit or the lower limit. Use one of the options:
|
neg_valuesFM |
Scalar indicating the method to use for the removal of the
anomalies from the lower limit of the dynamic range. Use |
html_report |
Suffix to be added to the FCS filename to name the HTML
report of the quality control. The default is |
mini_report |
Name for the TXT file containing the percentage of
anomalies detected in the set of FCS files
analyzed. The default is |
fcs_QC |
Suffix to be added for the filename of the new FCS
containing a new parameter where the low quality events only have a value
higher than 10,000. The default is |
fcs_highQ |
Suffix to be added for the filename of the new FCS
containing only the events that passed the quality control. The default
is |
fcs_lowQ |
Suffix to be added for the filename of the new FCS
containing only the events that did not pass the quality control. The default
is |
folder_results |
Character string used to name the directory that
contains the results. The default is |
A complete quality control is performed on flow cytometry data in FCS format. By default the analysis returns:
1. a flowFrame or flowSet object containing new FCS files with only high quality events
and a directory named resultsQC containing:
1. a set of new FCS files with a new parameter to gate out the low quality events a value larger than 10,000 is assigned to them only,
2. a set of HTML reports, one for each FCS file, that include graphs and table indicating where the anomalies were detected,
3. a single TXT file reporting the percentage of events removed in each FCS file.