Description

Apply water reference scaling to a fitting results object to yield metabolite quantities in millimolar (mM) units (mol/litre).

Usage

1
scale_amp_molar(fit_result, ref_data, w_att = 0.7, w_conc = 35880, ...)

Arguments

fit_result

a result object generated from fitting.

ref_data

water reference MRS data object.

w_att

water attenuation factor (default = 0.7).

w_conc

assumed water concentration (default = 35880).

...

additional arguments to get_td_amp function.

Value

a fit_result object with a rescaled results table.