#' Cmax for 2-compartmental PK model, bolus dosing at steady state
#'
#' @param dose dose
#' @param tau dosing interval
#' @param CL clearance
#' @param V volume of central compartment
#' @param Q inter-compartimental clearance
#' @param V2 volume of peripheral compartment
#' @param ruv residual error (list)
#' @export
pk_2cmt_bolus_cmax_ss <- function(
dose = 100,
tau = 12,
CL = 3,
V = 30,
Q = 2,
V2 = 20,
ruv = NULL
) {
return(pk_2cmt_bolus_ss(
t=0,
dose = dose, tau=tau,
CL=CL, V=V, Q=Q, V2=V2,
ruv=ruv)$dv)
}