XCMS.align.matchedFilter: XCMS.align.matchedFilter

Description Usage Arguments Details Value Note Author(s)

Description

Runs XCMS using the matchedFilter alignment algorithm at different parameter settings.

Usage

1
2
3
4
5
XCMS.align.matchedFilter(cdfloc, XCMS.outloc, step.list = c(0.001), 
    mz.diff.list = c(0.1), sn.thresh.list = c(3), max = 50, bw.val = c(10), 
    minfrac.val = 0.5, minsamp.val = 2, mzwid.val = 0.25, sleep.val = 0, 
    run.order.file = NA, subs = NA, retcor.family = "symmetric", 
    retcor.plottype = "mdevden", groupval.method = "medret")

Arguments

cdfloc

The folder where all CDF/mzXML files to be processed are located. For example "C:/CDF/"

XCMS.outloc

The folder where alignment output will be written. For example "C:/CDFoutput/"

step.list

list containing values for the step size

mz.diff.list

list containing values for the minimum difference for features with retention time overlap

sn.thresh.list

list containing values for signal to noise ratio cutoff variable

max

Value for maxnimum number of peaks per EIC variable: eg: 5

bw.val

bandwidth value

minfrac.val

minimum fraction of samples necessary in at least one of the sample groups for it to be a valid group

minsamp.val

minimum number of samples necessary in at least one of the sample groups for it to be a valid group

mzwid.val

width of overlapping m/z slices to use for creating peak density chromatograms and grouping peaks across samples

sleep.val

seconds to pause between plotting successive steps of the peak grouping algorithm. peaks are plotted as points showing relative intensity. identified groups are flanked by dotted vertical lines.

run.order.file

Name of a tab-delimited file that includes sample names sorted by the order in which they were run(sample names must match the CDF file names)

subs

If not all the CDF files in the folder are to be processed, the user can define a subset using this parameter. For example, subs=15:30, or subs=c(2,4,6,8)

retcor.family

Used by matchedFilter alignment method. Use "gaussian" to perform fitting by least squares without outlier removal. Or "symmetric" to use a redescending M estimator with Tukey's biweight function that allows outlier removal.

retcor.plottype

Used by both matchedFilter and centWave alignment methods. eg: "deviation" or "mdevden"

groupval.method

Conflict resolution method while calculating peak values for each group. eg: "medret" or "maxint"

Details

This is a wrapper function based on the xcms Bioconductor package for preprocessing/analysis of mass spectral data. The XCMS.align utility performs serial sample processing at multiple combinations of four parameters: step (the step size; default values: 0.001, 0.01, 0.1), mzdiff (minimum difference for features with retention time overlap; default values: 0.001, 0.01, 0.1), snthresh (signal-to-noise ratio cutoff; default values: 3, 6, 10), and max (maximum number of peaks per EIC; default values: 5, 10). The resulting tables containing m/z, retention time, and mean peak intensities in each sample are stored at each parameter combination.

Value

A matrix, with columns of m/z values, elution times, mean signal strengths in each spectrum

Note

Please refer to the xcms manual in Bioconductor for more details.

Author(s)

Karan Uppal <kuppal2@emory.edu>