#' Reliability-Oriented Sobol Indices
#'
#' Transform stored simulator samples into Sobol indices for the binary failure
#' indicator described by Lebrun et al. (2021). The function reuses the
#' Saltelli-type estimator from [sobol_indices()] and therefore requires a
#' previous call with `keep_samples = TRUE`.
#'
#' @param result Output of [sobol_indices()] computed with
#' `keep_samples = TRUE`.
#' @param threshold Numeric scalar defining the failure boundary.
#' @param less Logical, when `TRUE` failures correspond to
#' `response <= threshold`; otherwise, failures correspond to
#' `response >= threshold`.
#' @return A `sobol_result` instance storing the Sobol indices of the failure
#' indicator along with the estimated failure probability and its variance.
#' @examples
#' design <- sobol_design(n = 128, d = 3, lower = rep(-pi, 3), upper = rep(pi, 3))
#' stochastic <- sobol_indices(ishigami_model, design, replicates = 3,
#' keep_samples = TRUE)
#' failure <- sobol_reliability(stochastic, threshold = -1)
#' Sobol4R::autoplot(failure, show_uncertainty = TRUE)
#' @export
sobol_reliability <- function(result, threshold, less = TRUE) {
stopifnot(inherits(result, "sobol_result"))
samples <- result$samples
if (is.null(samples)) {
stop("sobol_reliability() requires 'keep_samples = TRUE' in sobol_indices().")
}
if (length(threshold) != 1L || !is.finite(threshold)) {
stop("threshold must be a single finite numeric value.")
}
parameters <- result$parameters
if (is.null(parameters)) {
parameters <- names(samples$mixes)
}
parameters <- result$parameters
if (is.null(parameters)) {
parameters <- paste0("X", seq_along(samples$mixes))
}
indicator_A <- failure_indicator(samples$A, threshold, less)
indicator_B <- failure_indicator(samples$B, threshold, less)
indicator_mixes <- lapply(samples$mixes, failure_indicator,
threshold = threshold, less = less)
va <- stats::var(c(indicator_A, indicator_B))
if (!is.finite(va) || va <= 0) {
stop("Failure indicator variance is zero; adjust the threshold or sample size.")
}
first <- vapply(indicator_mixes, function(mix) {
mean(indicator_B * (mix - indicator_A)) / va
}, numeric(1L))
total <- vapply(indicator_mixes, function(mix) {
0.5 * mean((indicator_A - mix)^2) / va
}, numeric(1L))
weights_pb <- rep(1 / (length(indicator_A) + length(indicator_B)),
length(indicator_A) + length(indicator_B))
failure_stats <- estimate_failure_probability(
response = c(indicator_A, indicator_B),
threshold = 0.5,
less = FALSE,
weights = weights_pb
)
output <- list(
call = match.call(),
parameters = parameters,
first_order = as.numeric(first),
total_order = as.numeric(total),
variance = va,
estimator = "saltelli",
replicates = 1L,
mean_A = mean(indicator_A),
noise_variance = 0,
failure_probability = failure_stats$probability,
failure_variance = failure_stats$variance,
threshold = threshold,
less = less,
data = data.frame(parameter = parameters,
first_order = as.numeric(first),
total_order = as.numeric(total))
)
output$samples <- list(
A = list(values = matrix(indicator_A, ncol = 1L)),
B = list(values = matrix(indicator_B, ncol = 1L)),
mixes = lapply(indicator_mixes, function(mix) {
list(values = matrix(mix, ncol = 1L))
})
)
class(output) <- "sobol_result"
output
}
failure_indicator <- function(block, threshold, less) {
values <- block$values
if (is.null(values)) {
stop("Stored samples are missing raw 'values'. Re-run sobol_indices() with keep_samples = TRUE.")
}
values <- as.matrix(values)
if (!is.numeric(values)) {
stop("Stored samples must be numeric.")
}
averages <- rowMeans(values, na.rm = TRUE)
if (any(is.na(averages))) {
stop("Failure indicator encountered rows with only missing values.")
}
indicator <- if (isTRUE(less)) averages <= threshold else averages >= threshold
as.numeric(indicator)
}