pk_2cmt_bolus_cmax_ss: Cmax for 2-compartmental PK model, bolus dosing at steady...

View source: R/pk_2cmt_bolus_cmax_ss.R

pk_2cmt_bolus_cmax_ssR Documentation

Cmax for 2-compartmental PK model, bolus dosing at steady state

Description

Cmax for 2-compartmental PK model, bolus dosing at steady state

Usage

pk_2cmt_bolus_cmax_ss(
  dose = 100,
  tau = 12,
  CL = 3,
  V = 30,
  Q = 2,
  V2 = 20,
  ruv = NULL
)

Arguments

dose

dose

tau

dosing interval

CL

clearance

V

volume of central compartment

Q

inter-compartimental clearance

V2

volume of peripheral compartment

ruv

residual error (list)

Examples

pk_2cmt_bolus_cmax_ss(dose = 1000, tau = 12, CL = 5, V = 50, Q = 20, V2 = 200)